These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

81 related articles for article (PubMed ID: 21864780)

  • 1. Effect of sample thickness, energy filtering, and probe coherence on fluctuation electron microscopy experiments.
    Yi F; Voyles PM
    Ultramicroscopy; 2011 Jul; 111(8):1375-80. PubMed ID: 21864780
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A phenomenological model of fluctuation electron microscopy for a nanocrystal/amorphous composite.
    Stratton WG; Voyles PM
    Ultramicroscopy; 2008 Jul; 108(8):727-36. PubMed ID: 18155358
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Critical assessment of the speckle statistics in fluctuation electron microscopy and comparison to electron diffraction.
    Jungk T; Walther T; Mader W
    Ultramicroscopy; 2005 Oct; 104(3-4):206-19. PubMed ID: 15936145
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Examination of a polycrystalline thin-film model to explore the relation between probe size and structural correlation length in fluctuation electron microscopy.
    Treacy MM; Gibson JM
    Microsc Microanal; 2012 Feb; 18(1):241-53. PubMed ID: 22258727
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative comparison of energy-filtering transmission electron microscopy and atom probe tomography.
    Stender P; Heil T; Kohl H; Schmitz G
    Ultramicroscopy; 2009 Apr; 109(5):612-8. PubMed ID: 19201097
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Variable resolution fluctuation electron microscopy on Cu-Zr metallic glass using a wide range of coherent STEM probe size.
    Hwang J; Voyles PM
    Microsc Microanal; 2011 Feb; 17(1):67-74. PubMed ID: 21122191
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Strain analysis of Si by FEM and energy-filtering CBED.
    Okuyama T; Nakayama M; Tomokiyo Y; Van Der Biest O
    Microsc Microanal; 2002 Feb; 8(1):11-5. PubMed ID: 12533199
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Low-energy electron scattering in carbon-based materials analyzed by scanning transmission electron microscopy and its application to sample thickness determination.
    Pfaff M; Müller E; Klein MF; Colsmann A; Lemmer U; Krzyzanek V; Reichelt R; Gerthsen D
    J Microsc; 2011 Jul; 243(1):31-9. PubMed ID: 21155995
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Treating Knock-On Displacements in Fluctuation Electron Microscopy Experiments.
    Radić D; Peterlechner M; Posselt M; Bracht H
    Microsc Microanal; 2022 Sep; ():1-11. PubMed ID: 36047128
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Direct whole-mount imaging of fungal spores by energy-filtering transmission electron microscopy.
    Kim KW
    Micron; 2009 Feb; 40(2):279-83. PubMed ID: 18707893
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thin dielectric film thickness determination by advanced transmission electron microscopy.
    Diebold AC; Foran B; Kisielowski C; Muller DA; Pennycook SJ; Principe E; Stemmer S
    Microsc Microanal; 2003 Dec; 9(6):493-508. PubMed ID: 14750984
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Searching ultimate nanometrology for AlOx thickness in magnetic tunnel junction by analytical electron microscopy and X-ray reflectometry.
    Song SA; Hirano T; Park JB; Kaji K; Kim KH; Terada S
    Microsc Microanal; 2005 Oct; 11(5):431-45. PubMed ID: 17481324
    [TBL] [Abstract][Full Text] [Related]  

  • 13. MS-STEM-FEM: A parallelized multi-slice fluctuation TEM simulation tool.
    Julian NH; Li TT; Rudd RE; Marian J
    Ultramicroscopy; 2018 Nov; 194():117-125. PubMed ID: 30114605
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fluctuation microscopy analysis of amorphous silicon models.
    Gibson JM; Treacy MMJ
    Ultramicroscopy; 2017 May; 176():74-79. PubMed ID: 28190536
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative secondary electron energy filtering in a scanning electron microscope and its applications.
    Kazemian P; Mentink SA; Rodenburg C; Humphreys CJ
    Ultramicroscopy; 2007; 107(2-3):140-50. PubMed ID: 16872746
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Engery-filtering transmission electron microscopy of biological specimens.
    de Bruijn WC; Sorber CW; Gelsema ES; Beckers AL; Jongkind JF
    Scanning Microsc; 1993 Jun; 7(2):693-708; discussion 709. PubMed ID: 9026905
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of energy-filtering transmission electron microscopy for routine ultrastructural analysis of high-pressure-frozen or chemically fixed plant cells.
    Lütz-Meindl U; Aichinger N
    Protoplasma; 2004 Jun; 223(2-4):155-62. PubMed ID: 15221520
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retrieval of absorptive potential variation in electron beam sensitive specimens using a single energy-filtered bright-field TEM image.
    Bhattacharyya S; Jinschek JR
    Microsc Res Tech; 2008 Sep; 71(9):669-75. PubMed ID: 18613096
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Medium range order of bulk metallic glasses determined by variable resolution fluctuation electron microscopy.
    Deng JW; Du K; Sui ML
    Micron; 2012 Jul; 43(7):827-31. PubMed ID: 22391100
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Energy-filtered electron-diffracted beam holography.
    Herring RA
    Ultramicroscopy; 2005 Oct; 104(3-4):261-70. PubMed ID: 15996821
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.