These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 2187241)

  • 21. An automated turbidimetric rate method for immunoglobulin assays.
    Malkus H; Buschbaum P; Castro A
    Clin Chim Acta; 1978 Sep; 88(3):523-30. PubMed ID: 100261
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Solubility properties of IgG immune complexes. Comparison between the effects of low molecular weight solvents and polyethylene glycols.
    Johansen AS; Steensgaard J; Jacobsen C
    Immunology; 1980 Nov; 41(3):695-704. PubMed ID: 7461709
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A fully automated immuno-turbidimetric determination of fibrin(ogen) degradation products.
    Hoak DR; Mammen EF; Banerjee SK; Kaldor G
    Thromb Res; 1986 Oct; 44(1):1-10. PubMed ID: 3538493
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Characterization of circulating immune complexes by nephelometry in acute leukaemia.
    Mód A; Füst G; Hollán SR
    Clin Lab Haematol; 1982; 4(2):139-47. PubMed ID: 7116794
    [No Abstract]   [Full Text] [Related]  

  • 25. Anti-IgG combined with rate nephelometry for measuring polyethylene glycol-precipitated circulating immune complexes.
    Feldkamp CS; Levinson SS; Perry M; Amin V
    Clin Chem; 1985 Dec; 31(12):2024-7. PubMed ID: 4064293
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Improved immunoturbidimetric assay for cystatin C.
    Lewis AV; James TJ; McGuire JB; Taylor RP
    Ann Clin Biochem; 2001 Mar; 38(Pt 2):111-4. PubMed ID: 11269749
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Kinetic turbidimetric method for the immunochemical quantification of immunoglobulins, including samples with excess antigen.
    Skoug JW; Pardue HL
    Clin Chem; 1988 Feb; 34(2):309-15. PubMed ID: 3277747
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Influence of affinity of antibodies upon their detection by liquid phase radiobinding assay and solid phase enzyme linked immunosorbent assay. Demonstration using monoclonal antibodies raised against rDNA human proinsulin.
    Sodoyez JC; Koch M; Lemaire I; Sodoyez-Goffaux F; Rapaille A; François-Gérard C; Sondag D
    Diabetologia; 1991 Jul; 34(7):463-8. PubMed ID: 1916050
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Ammonium sulphate enhancement of the antigen-antibody reaction. Manual and automated nephelometric studies.
    Stakenburg J
    Clin Chim Acta; 1979 Feb; 91(3):251-61. PubMed ID: 761401
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A double antigen bridging immunogenicity ELISA for the detection of antibodies to polyethylene glycol polymers.
    Liu Y; Reidler H; Pan J; Milunic D; Qin D; Chen D; Vallejo YR; Yin R
    J Pharmacol Toxicol Methods; 2011; 64(3):238-45. PubMed ID: 21827863
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Avidity of antibodies to dsDNA: comparison of IFT on Crithidia luciliae, Farr assay, and PEG assay.
    Smeenk R; van der Lelij G; Aarden L
    J Immunol; 1982 Jan; 128(1):73-8. PubMed ID: 7033379
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Development of an automated turbidimetric immunoassay for quantification of bovine serum immunoglobulin G.
    Etzel LR; Strohbehn RE; McVicker JK
    Am J Vet Res; 1997 Nov; 58(11):1201-5. PubMed ID: 9361878
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Determination of the functional affinity of IgG1 and IgG4 antibodies to tetanus toxoid by isotype-specific solid-phase assays.
    Devey ME; Bleasdale K; Lee S; Rath S
    J Immunol Methods; 1988 Jan; 106(1):119-25. PubMed ID: 2448383
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effect of polyethylene glycol on the rate of immune complex formation by non-precipitating antibody.
    Rypácek F; Straková D; Kratochivíl P; Drobník J; Franék F
    Immunol Lett; 1982 Jan; 4(1):49-52. PubMed ID: 7061113
    [TBL] [Abstract][Full Text] [Related]  

  • 35. A simple light-scattering method for detecting soluble immune complexes in human serum.
    Koethe SM; Melton HE; Jendrzejczak Z
    Am J Clin Pathol; 1980 Dec; 74(6):804-8. PubMed ID: 7446490
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Interference of immune complexes and lipoproteins in the assay of immunoglobulin M by kinetic immunonephelometry].
    Coquelin H; Boucaud-Maitre Y; Cloppet H; Hutinel P
    Ann Biol Clin (Paris); 1982; 40(4):341-2. PubMed ID: 6816106
    [No Abstract]   [Full Text] [Related]  

  • 37. Immunoassay of alpha 1-acid glycoprotein in the Cobas Bio centrifugal analyzer.
    Verme CN; Ludden TM; Harris SC
    Clin Chem; 1988 Nov; 34(11):2316-20. PubMed ID: 3052925
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Monoclonal antibodies to human IgG: reaction characteristics in the centrifugal analyzer.
    Deverill I; Jefferis R; Ling NR; Reeves WG
    Clin Chem; 1981 Dec; 27(12):2044-7. PubMed ID: 7307257
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of turbidimetric and light-scattering measurements of immunoglobulins by use of a centrifugal analyzer with absorbance and fluorescence/light-scattering optics.
    Hills LP; Tiffany TO
    Clin Chem; 1980 Sep; 26(10):1459-66. PubMed ID: 7408174
    [TBL] [Abstract][Full Text] [Related]  

  • 40. On the composition of IgG anti-IgG immune complexes.
    Steensgaard J; Johansen AS; Jacobsen C
    Immunology; 1979 Dec; 38(4):697-704. PubMed ID: 316416
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.