159 related articles for article (PubMed ID: 21872480)
1. A simplified analytical approach to estimate the parameters required for strength determination of HDR 192Ir brachytherapy sources using a Farmer-type ionization chamber.
Kumar S; Srinivasan P; Sharma SD; Mayya YS
Appl Radiat Isot; 2012 Jan; 70(1):282-9. PubMed ID: 21872480
[TBL] [Abstract][Full Text] [Related]
2. Evaluation of scatter contribution and distance error by iterative methods for strength determination of HDR 192Ir brachytherapy source.
Kumar S; Srinivasan P; Sharma SD; Subbaiah KV; Mayya YS
Med Dosim; 2010; 35(3):230-7. PubMed ID: 19931038
[TBL] [Abstract][Full Text] [Related]
3. Correction factors for source strength determination in HDR brachytherapy using the in-phantom method.
Ubrich F; Wulff J; Engenhart-Cabillic R; Zink K
Z Med Phys; 2014 May; 24(2):138-52. PubMed ID: 24021956
[TBL] [Abstract][Full Text] [Related]
4. Calibration coefficient of reference brachytherapy ionization chamber using analytical and Monte Carlo methods.
Kumar S; Srinivasan P; Sharma SD
Appl Radiat Isot; 2010 Jun; 68(6):1108-15. PubMed ID: 20079657
[TBL] [Abstract][Full Text] [Related]
5. The design of a new insert for calibration of LDR and HDR 192Ir sources in a well-type ionization chamber.
Pineda AE; Alcón EP; deAlmeida CE
Med Phys; 2003 Jul; 30(7):1566-8. PubMed ID: 12906174
[TBL] [Abstract][Full Text] [Related]
6. The IPEM code of practice for determination of the reference air kerma rate for HDR (192)Ir brachytherapy sources based on the NPL air kerma standard.
Bidmead AM; Sander T; Locks SM; Lee CD; Aird EG; Nutbrown RF; Flynn A;
Phys Med Biol; 2010 Jun; 55(11):3145-59. PubMed ID: 20479510
[TBL] [Abstract][Full Text] [Related]
7. The mean photon energy ĒF at the point of measurement determines the detector-specific radiation quality correction factor kQ,M in (192)Ir brachytherapy dosimetry.
Chofor N; Harder D; Selbach HJ; Poppe B
Z Med Phys; 2016 Sep; 26(3):238-50. PubMed ID: 26387927
[TBL] [Abstract][Full Text] [Related]
8. A BrachyPhantom for verification of dose calculation of HDR brachytherapy planning system.
Austerlitz C; Campos CA
Med Phys; 2013 Nov; 40(11):112103. PubMed ID: 24320456
[TBL] [Abstract][Full Text] [Related]
9. Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty.
van Dijk E; Kolkman-Deurloo IK; Damen PM
Med Phys; 2004 Oct; 31(10):2826-33. PubMed ID: 15543790
[TBL] [Abstract][Full Text] [Related]
10. Audit on source strength determination for HDR and PDR (192)Ir brachytherapy in Sweden.
Carlsson Tedgren A; Grindborg JE
Radiother Oncol; 2008 Jan; 86(1):126-30. PubMed ID: 18187219
[TBL] [Abstract][Full Text] [Related]
11. Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE.
Casado FJ; García-Pareja S; Cenizo E; Mateo B; Bodineau C; Galán P
Phys Med; 2010; 26(3):132-9. PubMed ID: 20034828
[TBL] [Abstract][Full Text] [Related]
12. Air-kerma strength determination of an HDR
Smith BR; Micka JA; Aima M; DeWerd LA; Culberson WS
Med Phys; 2017 Jan; 44(1):311-320. PubMed ID: 28102953
[TBL] [Abstract][Full Text] [Related]
13. An experimental MOSFET approach to characterize (192)Ir HDR source anisotropy.
Toye WC; Das KR; Todd SP; Kenny MB; Franich RD; Johnston PN
Phys Med Biol; 2007 Sep; 52(17):5329-39. PubMed ID: 17762089
[TBL] [Abstract][Full Text] [Related]
14. A radiation quality correction factor k for well-type ionization chambers for the measurement of the reference air kerma rate of (60)Co HDR brachytherapy sources.
Schüller A; Meier M; Selbach HJ; Ankerhold U
Med Phys; 2015 Jul; 42(7):4285-94. PubMed ID: 26133626
[TBL] [Abstract][Full Text] [Related]
15. A practical implementation of the 2010 IPEM high dose rate brachytherapy code of practice for the calibration of 192Ir sources.
Awunor OA; Lecomber AR; Richmond N; Walker C
Phys Med Biol; 2011 Aug; 56(16):5397-410. PubMed ID: 21804181
[TBL] [Abstract][Full Text] [Related]
16. Evaluation of dosimetric parameters for various 192Ir brachytherapy sources under unbounded phantom geometry by Monte Carlo simulation.
Devan K; Aruna P; Manigandan D; Bharanidharan G; Subbaiah KV; Sunny CS; Ganesan S
Med Dosim; 2007; 32(4):305-15. PubMed ID: 17980833
[TBL] [Abstract][Full Text] [Related]
17. Source geometry factors for HDR ¹⁹²Ir brachytherapy secondary standard well-type ionization chamber calibrations.
Shipley DR; Sander T; Nutbrown RF
Phys Med Biol; 2015 Mar; 60(6):2573-86. PubMed ID: 25761529
[TBL] [Abstract][Full Text] [Related]
18. Monte Carlo aided design of an improved well-type ionization chamber for low energy brachytherapy sources.
Bohm TD; Micka JA; DeWerd LA
Med Phys; 2007 Apr; 34(4):1274-85. PubMed ID: 17500459
[TBL] [Abstract][Full Text] [Related]
19. Measurement of absorbed dose-to-water for an HDR (192)Ir source with ionization chambers in a sandwich setup.
Araki F; Kouno T; Ohno T; Kakei K; Yoshiyama F; Kawamura S
Med Phys; 2013 Sep; 40(9):092101. PubMed ID: 24007170
[TBL] [Abstract][Full Text] [Related]
20. A parallel plate chamber for calibration of 192Ir LDR and HDR sources.
Das KR; Kenny MB
Med Phys; 1999 Nov; 26(11):2438-40. PubMed ID: 10587229
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]