These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Current Methods of Haemolysis Detection and Reporting as a Source of Risk to Patient Safety: a Narrative Review. McCaughey EJ; Vecellio E; Lake R; Li L; Burnett L; Chesher D; Braye S; Mackay M; Gay S; Badrick TC; Westbrook JI; Georgiou A Clin Biochem Rev; 2016 Dec; 37(4):143-151. PubMed ID: 28167844 [TBL] [Abstract][Full Text] [Related]
24. Methods for Hemolysis Interference Study in Laboratory Medicine - A Critical Review. Marques-Garcia F EJIFCC; 2020 Mar; 31(1):85-97. PubMed ID: 32256292 [TBL] [Abstract][Full Text] [Related]
25. Key factors influencing the incidence of hemolysis: A critical appraisal of current evidence. McCaughey EJ; Vecellio E; Lake R; Li L; Burnett L; Chesher D; Braye S; Mackay M; Gay S; Badrick T; Westbrook J; Georgiou A Crit Rev Clin Lab Sci; 2017 Jan; 54(1):59-72. PubMed ID: 28013559 [TBL] [Abstract][Full Text] [Related]
26. Prevention of hemolysis in blood samples collected from intravenous catheters. Lippi G; Avanzini P; Cervellin G Clin Biochem; 2013 May; 46(7-8):561-4. PubMed ID: 23391635 [TBL] [Abstract][Full Text] [Related]
27. Serum indices: managing assay interference. Farrell CJ; Carter AC Ann Clin Biochem; 2016 Sep; 53(Pt 5):527-38. PubMed ID: 27147624 [TBL] [Abstract][Full Text] [Related]
28. Mistakes in a stat laboratory: types and frequency. Plebani M; Carraro P Clin Chem; 1997 Aug; 43(8 Pt 1):1348-51. PubMed ID: 9267312 [TBL] [Abstract][Full Text] [Related]
29. Hemolysis indexes for biochemical tests and immunoassays on Roche analyzers: determination of allowable interference limits according to different calculation methods. Monneret D; Mestari F; Atlan G; Corlouer C; Ramani Z; Jaffre J; Dever S; Fressart V; Alkouri R; Lamari F; Devilliers C; Imbert-Bismut F; Bonnefont-Rousselot D Scand J Clin Lab Invest; 2015 Apr; 75(2):162-9. PubMed ID: 25608598 [TBL] [Abstract][Full Text] [Related]
30. Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters. Heiligers-Duckers C; Peters NALR; van Dijck JJP; Hoeijmakers JMJ; Janssen MJW Clin Biochem; 2013 Aug; 46(12):1142-1144. PubMed ID: 23603143 [TBL] [Abstract][Full Text] [Related]
31. The influence of bilirubin, haemolysis and turbidity on 20 analytical tests performed on automatic analysers. Results of an interlaboratory study. Grafmeyer D; Bondon M; Manchon M; Levillain P Eur J Clin Chem Clin Biochem; 1995 Jan; 33(1):31-52. PubMed ID: 7756439 [TBL] [Abstract][Full Text] [Related]
32. Effects of nonsteroidal antiinflammatory drugs on platelet function and systemic hemostasis. Schafer AI J Clin Pharmacol; 1995 Mar; 35(3):209-19. PubMed ID: 7608308 [TBL] [Abstract][Full Text] [Related]
33. Hemolyzed Specimens: Major Challenge for Identifying and Rejecting Specimens in Clinical Laboratories. Wan Azman WN; Omar J; Koon TS; Tuan Ismail TS Oman Med J; 2019 Mar; 34(2):94-98. PubMed ID: 30918601 [TBL] [Abstract][Full Text] [Related]
34. Do hemolyzed potassium specimens need to be repeated? Khodorkovsky B; Cambria B; Lesser M; Hahn B J Emerg Med; 2014 Sep; 47(3):313-7. PubMed ID: 24930444 [TBL] [Abstract][Full Text] [Related]
35. A step closer in reducing hemolysis in blood samples collected in the emergency department. Kavsak PA Clin Biochem; 2013 May; 46(7-8):565. PubMed ID: 23582454 [No Abstract] [Full Text] [Related]