BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 21892943)

  • 1. In vivo assessment of catheter positioning accuracy and prolonged irradiation time on liver tolerance dose after single-fraction 192Ir high-dose-rate brachytherapy.
    Lüdemann L; Wybranski C; Seidensticker M; Mohnike K; Kropf S; Wust P; Ricke J
    Radiat Oncol; 2011 Sep; 6():107. PubMed ID: 21892943
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo assessment of dose volume and dose gradient effects on the tolerance dose of small liver volumes after single-fraction high-dose-rate 192Ir irradiation.
    Wybranski C; Seidensticker M; Mohnike K; Kropf S; Wust P; Ricke J; Lüdemann L
    Radiat Res; 2009 Nov; 172(5):598-606. PubMed ID: 19883228
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effect of catheter displacement and anatomical variations on the dose distribution in MRI-guided focal HDR brachytherapy for prostate cancer.
    Maenhout M; van der Voort van Zyp JRN; Borot de Battisti M; Peters M; van Vulpen M; van den Bosch M; Moerland MA
    Brachytherapy; 2018; 17(1):68-77. PubMed ID: 28579419
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of applicator tip reconstruction in MRI-guided interstitial 192Ir-high-dose-rate brachytherapy of liver tumors.
    Wybranski C; Eberhardt B; Fischbach K; Fischbach F; Walke M; Hass P; Röhl FW; Kosiek O; Kaiser M; Pech M; Lüdemann L; Ricke J
    Radiother Oncol; 2015 Apr; 115(1):72-7. PubMed ID: 25779722
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy.
    Poulin E; Fekete CA; Létourneau M; Fenster A; Pouliot J; Beaulieu L
    Med Phys; 2013 Nov; 40(11):111724. PubMed ID: 24320432
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of liver exposure in CT-guided high-dose rate (HDR) interstitial brachytherapy versus SBRT in hepatocellular carcinoma.
    Walter F; Nierer L; Rottler M; Duque AS; Weingandt H; Well J; Shpani R; Landry G; Seidensticker M; Streitparth F; Ricke J; Belka C; Corradini S
    Radiat Oncol; 2021 May; 16(1):86. PubMed ID: 33957941
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative in vivo assessment of radiation injury of the liver using Gd-EOB-DTPA enhanced MRI: tolerance dose of small liver volumes.
    Seidensticker M; Seidensticker R; Mohnike K; Wybranski C; Kalinski T; Luess S; Pech M; Wust P; Ricke J
    Radiat Oncol; 2011 Apr; 6():40. PubMed ID: 21496320
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vivo assessment of the tolerance dose of small liver volumes after single-fraction HDR irradiation.
    Ricke J; Seidensticker M; Lüdemann L; Pech M; Wieners G; Hengst S; Mohnike K; Cho CH; Lopez Hänninen E; Al-Abadi H; Felix R; Wust P
    Int J Radiat Oncol Biol Phys; 2005 Jul; 62(3):776-84. PubMed ID: 15936559
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy.
    Wang W; Viswanathan AN; Damato AL; Chen Y; Tse Z; Pan L; Tokuda J; Seethamraju RT; Dumoulin CL; Schmidt EJ; Cormack RA
    Med Phys; 2015 Dec; 42(12):7114-21. PubMed ID: 26632065
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 3D dose verification in 192Ir HDR prostate monotherapy using polymer gels and MRI.
    Kipouros P; Papagiannis P; Sakelliou L; Karaiskos P; Sandilos P; Baras P; Seimenis I; Kozicki M; Anagnostopoulos G; Baltas D
    Med Phys; 2003 Aug; 30(8):2031-9. PubMed ID: 12945969
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy.
    Yang X; Rossi P; Ogunleye T; Marcus DM; Jani AB; Mao H; Curran WJ; Liu T
    Med Phys; 2014 Nov; 41(11):111915. PubMed ID: 25370648
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [CT-Guided brachytherapy. A novel percutaneous technique for interstitial ablation of liver metastases].
    Ricke J; Wust P; Stohlmann A; Beck A; Cho CH; Pech M; Wieners G; Spors B; Werk M; Rosner C; Lopez Hänninen E; Felix R
    Strahlenther Onkol; 2004 May; 180(5):274-80. PubMed ID: 15127157
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A dosimetric comparison of 169Yb and 192Ir for HDR brachytherapy of the breast, accounting for the effect of finite patient dimensions and tissue inhomogeneities.
    Lymperopoulou G; Papagiannis P; Angelopoulos A; Karaiskos P; Georgiou E; Baltas D
    Med Phys; 2006 Dec; 33(12):4583-9. PubMed ID: 17278810
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of an MR-only interstitial gynecologic brachytherapy workflow using MR-line marker for catheter reconstruction.
    Shaaer A; Paudel M; Smith M; Tonolete F; Nicolae A; Leung E; Ravi A
    Brachytherapy; 2020; 19(5):642-650. PubMed ID: 32712027
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of HDR interstitial breast implants planned by conventional and optimized CT-based dosimetry systems with respect to dose homogeneity and conformality.
    Major T; Fodor J; Takácsi-Nagy Z; Agoston P; Polgár C
    Strahlenther Onkol; 2005 Feb; 181(2):89-96. PubMed ID: 15702297
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy.
    Therriault-Proulx F; Briere TM; Mourtada F; Aubin S; Beddar S; Beaulieu L
    Med Phys; 2011 May; 38(5):2542-51. PubMed ID: 21776789
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An integrated system for clinical treatment verification of HDR prostate brachytherapy combining source tracking with pretreatment imaging.
    Smith RL; Hanlon M; Panettieri V; Millar JL; Matheson B; Haworth A; Franich RD
    Brachytherapy; 2018; 17(1):111-121. PubMed ID: 28958735
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Online correction of catheter movement using CT in high-dose-rate prostate brachytherapy.
    Huang Y; Miller B; Doemer A; Babij D; Kumar S; Frontera R; Nurushev T; Chetty IJ; Aref I
    Brachytherapy; 2013; 12(3):260-6. PubMed ID: 23453680
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel urethral sparing technique for high-dose-rate prostate brachytherapy after transurethral resection of the prostate.
    Kunogi H; Cunha JAM; Chang AJ; Gadzinski AJ; Shinohara K; Hsu IC
    Brachytherapy; 2017; 16(6):1113-1118. PubMed ID: 28869143
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Unresectable colorectal liver metastases: percutaneous ablation using CT-guided high-dose-rate brachytherapy (CT-HDBRT).
    Collettini F; Lutter A; Schnapauff D; Hildebrandt B; Puhl G; Denecke T; Wust P; Gebauer B
    Rofo; 2014 Jun; 186(6):606-12. PubMed ID: 24407711
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.