BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 21895281)

  • 1. Note: Design and construction of a simple and reliable printed circuit board-substrate Bradbury-Nielsen gate for ion mobility spectrometry.
    Du Y; Cang H; Wang W; Han F; Chen C; Li L; Hou K; Li H
    Rev Sci Instrum; 2011 Aug; 82(8):086103. PubMed ID: 21895281
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A simple template-based transfer method to fabricate Bradbury-Nielsen gates with uniform tension for ion mobility spectrometry.
    Kai N; Jingran G; Guangli O; Yu L; Quan Y; Xiang Q; Xiaohao W
    Rev Sci Instrum; 2014 Aug; 85(8):085107. PubMed ID: 25173312
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A progressively reduced pretension method to fabricate Bradbury-Nielsen gates with uniform tension.
    Ni K; Guo J; Yu Z; Cao L; Yu Q; Qian X; Wang X
    Rev Sci Instrum; 2015 Nov; 86(11):115105. PubMed ID: 26628170
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bradbury-Nielsen-gate-grid structure for further enhancing the resolution of ion mobility spectrometry.
    Du Y; Wang W; Li H
    Anal Chem; 2012 Jul; 84(13):5700-7. PubMed ID: 22762264
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Resolution enhancement of ion mobility spectrometry by improving the three-zone properties of the Bradbury-Nielsen gate.
    Du Y; Wang W; Li H
    Anal Chem; 2012 Feb; 84(3):1725-31. PubMed ID: 22196767
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Selection of a Single Isotope of Multiply Charged Xenon (
    Kitashoji A; Yoshikawa T; Fujihara A; Kamamori T; Nashima S; Yatsuhashi T
    Chemphyschem; 2017 Aug; 18(15):2007-2011. PubMed ID: 28605574
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Printed circuit board ion trap mass analyzer: its structure and performance.
    Jiang D; Jiang GY; Li XX; Xu FX; Wang L; Ding L; Ding CF
    Anal Chem; 2013 Jun; 85(12):6041-6. PubMed ID: 23701673
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysis.
    Sysoev A; Adamov A; Viidanoja J; Ketola RA; Kostiainen R; Kotiaho T
    Rapid Commun Mass Spectrom; 2004; 18(24):3131-9. PubMed ID: 15565719
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Field Switching Combined with Bradbury-Nielsen Gate for Ion Mobility Spectrometry.
    Chen C; Tabrizchi M; Wang W; Li H
    Anal Chem; 2015 Aug; 87(15):7925-30. PubMed ID: 26143934
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Toward Compact High-Performance Ion Mobility Spectrometers: Ion Gating in Ion Mobility Spectrometry.
    Bohnhorst A; Kirk AT; Zimmermann S
    Anal Chem; 2021 Apr; 93(15):6062-6070. PubMed ID: 33825452
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enhancing ion mobility spectrometry performance through a programmable ion swarm shaping method based on Bradbury-Nielsen gates.
    Wang J; Chen H; Ling Y; Zhang C; Zhou H; Wang X; Ni K
    Talanta; 2024 Mar; 269():125396. PubMed ID: 37979507
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultrasonic recovery of copper and iron through the simultaneous utilization of Printed Circuit Boards (PCB) spent acid etching solution and PCB waste sludge.
    Huang Z; Xie F; Ma Y
    J Hazard Mater; 2011 Jan; 185(1):155-61. PubMed ID: 20932641
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pushing the Resolving Power of Tyndall-Powell Gate Ion Mobility Spectrometry over 100 with No Sensitivity Loss for Multiple Ion Species.
    Chen C; Chen H; Li H
    Anal Chem; 2017 Dec; 89(24):13398-13404. PubMed ID: 29188986
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High transmission 3D printed flex-PCB-based ion funnel.
    Tridas EM; Allemang C; Mast F; Anthony JM; Schlaf R
    J Mass Spectrom; 2015 Jul; 50(7):938-43. PubMed ID: 26349649
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Theoretical and experimental study of the achievable separation power in resistive-glass atmospheric pressure ion mobility spectrometry.
    Kwasnik M; Fernández FM
    Rapid Commun Mass Spectrom; 2010 Jul; 24(13):1911-8. PubMed ID: 20533321
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Micromachined Bradbury-Nielsen gates.
    Zuleta IA; Barbula GK; Robbins MD; Yoon OK; Zare RN
    Anal Chem; 2007 Dec; 79(23):9160-5. PubMed ID: 17966990
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Ambient Pressure Inverse Ion Mobility Spectrometry Coupled to Mass Spectrometry.
    Liu W; Davis AL; Siems WF; Yin D; Clowers BH; Hill HH
    Anal Chem; 2017 Mar; 89(5):2800-2806. PubMed ID: 28192980
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simple template-based method to produce Bradbury-Nielsen gates.
    Yoon OK; Zuleta IA; Robbins MD; Barbula GK; Zare RN
    J Am Soc Mass Spectrom; 2007 Nov; 18(11):1901-8. PubMed ID: 17827033
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Programmable gate delayed ion mobility spectrometry-mass spectrometry: a study with low concentrations of dipropylene-glycol-monomethyl-ether in air.
    Hill CA; Thomas CL
    Analyst; 2005 Aug; 130(8):1155-61. PubMed ID: 16021214
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Printed circuit board industry.
    LaDou J
    Int J Hyg Environ Health; 2006 May; 209(3):211-9. PubMed ID: 16580876
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.