These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

260 related articles for article (PubMed ID: 21895327)

  • 1. First-in-human pilot study of a spatial frequency domain oxygenation imaging system.
    Gioux S; Mazhar A; Lee BT; Lin SJ; Tobias AM; Cuccia DJ; Stockdale A; Oketokoun R; Ashitate Y; Kelly E; Weinmann M; Durr NJ; Moffitt LA; Durkin AJ; Tromberg BJ; Frangioni JV
    J Biomed Opt; 2011 Aug; 16(8):086015. PubMed ID: 21895327
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel pilot study using spatial frequency domain imaging to assess oxygenation of perforator flaps during reconstructive breast surgery.
    Nguyen JT; Lin SJ; Tobias AM; Gioux S; Mazhar A; Cuccia DJ; Ashitate Y; Stockdale A; Oketokoun R; Durr NJ; Moffitt LA; Durkin AJ; Tromberg BJ; Frangioni JV; Lee BT
    Ann Plast Surg; 2013 Sep; 71(3):308-15. PubMed ID: 23945533
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intraoperative Hemifacial Composite Flap Perfusion Assessment Using Spatial Frequency Domain Imaging: A Pilot Study in Preparation for Facial Transplantation.
    Vargas CR; Nguyen JT; Ashitate Y; Angelo J; Venugopal V; Kettenring F; Neacsu F; Frangioni JV; Gioux S; Lee BT
    Ann Plast Surg; 2016 Feb; 76(2):249-55. PubMed ID: 26418791
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Investigation of TRAM flap oxygenation and perfusion by near-infrared reflection spectroscopy and color-coded duplex sonography.
    Scheufler O; Exner K; Andresen R
    Plast Reconstr Surg; 2004 Jan; 113(1):141-52; discussion 153-5. PubMed ID: 14707632
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Regional transcranial oximetry with near infrared spectroscopy (NIRS) in comparison with measuring oxygen saturation in the jugular bulb in infants and children for monitoring cerebral oxygenation].
    Abdul-Khaliq H; Troitzsch D; Berger F; Lange PE
    Biomed Tech (Berl); 2000 Nov; 45(11):328-32. PubMed ID: 11155535
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Tissue oxygenation and perfusion in inferior pedicle reduction mammaplasty by near-infrared reflection spectroscopy and color-coded duplex sonography.
    Scheufler O; Andresen R
    Plast Reconstr Surg; 2003 Mar; 111(3):1131-46. PubMed ID: 12621183
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noninvasive tissue oximetry for flap monitoring: an initial study.
    Keller A
    J Reconstr Microsurg; 2007 May; 23(4):189-97. PubMed ID: 17530610
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Postoperative quantitative assessment of reconstructive tissue status in a cutaneous flap model using spatial frequency domain imaging.
    Yafi A; Vetter TS; Scholz T; Patel S; Saager RB; Cuccia DJ; Evans GR; Durkin AJ
    Plast Reconstr Surg; 2011 Jan; 127(1):117-130. PubMed ID: 21200206
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantitative short-wave infrared multispectral imaging of in vivo tissue optical properties.
    Wilson RH; Nadeau KP; Jaworski FB; Rowland R; Nguyen JQ; Crouzet C; Saager RB; Choi B; Tromberg BJ; Durkin AJ
    J Biomed Opt; 2014 Aug; 19(8):086011. PubMed ID: 25120175
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Near-infrared spectroscopy measures tissue oxygenation in free flaps for breast reconstruction.
    Colwell AS; Wright L; Karanas Y
    Plast Reconstr Surg; 2008 May; 121(5):344e-345e. PubMed ID: 18453956
    [No Abstract]   [Full Text] [Related]  

  • 11. OpenSFDI: an open-source guide for constructing a spatial frequency domain imaging system.
    Applegate M; Karrobi K; Angelo J; Austin W; Tabassum S; Aguénounon E; Tilbury K; Saager R; Gioux S; Roblyer D
    J Biomed Opt; 2020 Jan; 25(1):1-13. PubMed ID: 31925946
    [No Abstract]   [Full Text] [Related]  

  • 12. The use of near-infrared spectroscopy for assessing flap viability during reconstructive surgery.
    Thorniley MS; Sinclair JS; Barnett NJ; Shurey CB; Green CJ
    Br J Plast Surg; 1998 Apr; 51(3):218-26. PubMed ID: 9664881
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real-time, wide-field, and quantitative oxygenation imaging using spatiotemporal modulation of light.
    Schmidt M; Aguénounon E; Nahas A; Torregrossa M; Tromberg BJ; Uhring W; Gioux S
    J Biomed Opt; 2019 Mar; 24(7):1-7. PubMed ID: 30868804
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Muscle oxygenation by near-infrared-based tissue oximeters.
    Quaresima V; Ferrari M
    J Appl Physiol (1985); 2009 Jul; 107(1):371; author reply 372-3. PubMed ID: 19567814
    [No Abstract]   [Full Text] [Related]  

  • 15. Near-infrared spectroscopy: a methodology-focused review.
    Pellicer A; Bravo Mdel C
    Semin Fetal Neonatal Med; 2011 Feb; 16(1):42-9. PubMed ID: 20580625
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transabdominal fetal pulse oximetry with near-infrared spectroscopy.
    Vintzileos AM; Nioka S; Lake M; Li P; Luo Q; Chance B
    Am J Obstet Gynecol; 2005 Jan; 192(1):129-33. PubMed ID: 15672014
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spatial frequency domain imaging of port wine stain biochemical composition in response to laser therapy: a pilot study.
    Mazhar A; Sharif SA; Cuccia JD; Nelson JS; Kelly KM; Durkin AJ
    Lasers Surg Med; 2012 Oct; 44(8):611-21. PubMed ID: 22911574
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Applications of NIRS for measurements of tissue oxygenation and haemodynamics during surgery.
    Thorniley MS; Simpkin S; Barnett NJ; Wall P; Khaw KS; Shurey C; Sinclair JS; Green CJ
    Adv Exp Med Biol; 1997; 411():481-93. PubMed ID: 9269465
    [No Abstract]   [Full Text] [Related]  

  • 19. Tissue Oximetry and Clinical Outcomes.
    Bickler P; Feiner J; Rollins M; Meng L
    Anesth Analg; 2017 Jan; 124(1):72-82. PubMed ID: 27308951
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new diagnostic algorithm for early prediction of vascular compromise in 208 microsurgical flaps using tissue oxygen saturation measurements.
    Keller A
    Ann Plast Surg; 2009 May; 62(5):538-43. PubMed ID: 19387157
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.