111 related articles for article (PubMed ID: 21897321)
1. Usefulness of cone-beam computed tomography in determining the position of ossicular prostheses: a cadaveric model.
Monteiro E; Das P; Daly M; Chan H; Irish J; James A
Otol Neurotol; 2011 Oct; 32(8):1358-63. PubMed ID: 21897321
[TBL] [Abstract][Full Text] [Related]
2. Experimental Simulation of Clinical Borderline Situations in Temporal Bone Specimens After Ossiculoplasty.
Jakob TF; Kromeier J; Baumann T; Pfeiffer J; Neudert M; Laszig R; Zahnert T; Offergeld C
Ear Hear; 2018; 39(1):131-138. PubMed ID: 28671917
[TBL] [Abstract][Full Text] [Related]
3. A micro-computed tomographic study: determination of the angle between the tympanic membrane and stapes footplate in a total ossicular reconstruction prosthesis reconstruction.
Herkenhoff S; Fischer B; Gleich O; Strutz J; Kwok P
Otol Neurotol; 2011 Jun; 32(4):610-5. PubMed ID: 21389898
[TBL] [Abstract][Full Text] [Related]
4. Visualisation of passive middle ear implants by cone beam and multi-detector computed tomography: a comparative in vitro study.
Nguyen TD; Kösling S; Mlynski R; Plontke SK
Eur Radiol; 2016 Dec; 26(12):4538-4544. PubMed ID: 27027315
[TBL] [Abstract][Full Text] [Related]
5. Virtual Quality Control in Middle Ear Surgery: Is Image-guided Tympanoscopy a Valuable Tool for Depicting Borderline Situations?
Jakob TF; Zaoui K; Kromeier J; Baumann T; Becker C; Lasurashvili N; Neudert M; Beleites T; Offergeld C
Otol Neurotol; 2020 Aug; 41(7):e893-e900. PubMed ID: 32658106
[TBL] [Abstract][Full Text] [Related]
6. Comparisons of the mechanics of partial and total ossicular replacement prostheses with cartilage in a cadaveric temporal bone preparation.
Ulku CH; Cheng JT; Guignard J; Rosowski JJ
Acta Otolaryngol; 2014 Aug; 134(8):776-84. PubMed ID: 24847945
[TBL] [Abstract][Full Text] [Related]
7. Prospective evaluation of reliability of cone-beam computed tomography in detecting different position of vibroplasty middle ear implants.
Güldner C; Heinrichs J; Weiß R; Eivazi B; Bien S; Teymoortash A; Werner JA; Diogo I
Clin Otolaryngol; 2013 Jun; 38(3):217-24. PubMed ID: 23647580
[TBL] [Abstract][Full Text] [Related]
8. Quantitative analysis of 3D-printed custom ossicular prostheses motion using laser Doppler vibrometry.
Sokołowski J; Orłowski A; Bartoszewicz R; Lachowska M; Gosiewska A; Biecek P; Niemczyk K
Otolaryngol Pol; 2024 Feb; 77(6):23-30. PubMed ID: 38038405
[TBL] [Abstract][Full Text] [Related]
9. Position of TORP on the stapes footplate assessed with cone beam computed tomography.
Komori M; Yanagihara N; Hyodo J; Miuchi S
Otol Neurotol; 2012 Oct; 33(8):1353-6. PubMed ID: 22975904
[TBL] [Abstract][Full Text] [Related]
10. Middle ear reconstruction using the titanium Kurz Variac partial ossicular replacement prosthesis: functional results.
Meulemans J; Wuyts FL; Forton GE
JAMA Otolaryngol Head Neck Surg; 2013 Oct; 139(10):1017-25. PubMed ID: 24135742
[TBL] [Abstract][Full Text] [Related]
11. Partial ossicular reconstruction: comparison of three different prostheses in clinical and experimental studies.
Neudert M; Zahnert T; Lasurashvili N; Bornitz M; Lavcheva Z; Offergeld C
Otol Neurotol; 2009 Apr; 30(3):332-8. PubMed ID: 19174710
[TBL] [Abstract][Full Text] [Related]
12. Titanium ball joint total ossicular replacement prosthesis--experimental evaluation and midterm clinical results.
Gostian AO; Pazen D; Luers JC; Huttenbrink KB; Beutner D
Hear Res; 2013 Jul; 301():100-4. PubMed ID: 23142147
[TBL] [Abstract][Full Text] [Related]
13. Ossiculoplasty in missing malleus and stapes patients: experimental and preliminary clinical results with a new malleus replacement prosthesis with the otology-neurotology database.
Vincent R; Bittermann AJ; Wenzel G; Oates J; Sperling N; Lenarz T; Grolman W
Otol Neurotol; 2013 Jan; 34(1):83-90. PubMed ID: 23151778
[TBL] [Abstract][Full Text] [Related]
14. Restoring hearing using total ossicular replacement prostheses--analysis of 3D finite element model.
Yao W; Li B; Huang X; Guo C; Luo X; Zhou W; Duan M
Acta Otolaryngol; 2012 Feb; 132(2):152-9. PubMed ID: 22201262
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of hydroxyapatite ossicular chain prostheses.
Pasha R; Hill SL; Burgio DL
Otolaryngol Head Neck Surg; 2000 Oct; 123(4):425-9. PubMed ID: 11020179
[TBL] [Abstract][Full Text] [Related]
16. Ossiculoplasty with total ossicular replacement prosthesis and Omega Connector: early clinical results and functional measurements.
Mantei T; Chatzimichalis M; Sim JH; Schrepfer T; Vorburger M; Huber AM
Otol Neurotol; 2011 Sep; 32(7):1102-7. PubMed ID: 21730881
[TBL] [Abstract][Full Text] [Related]
17. Optimum tension for partial ossicular replacement prosthesis reconstruction in the human middle ear.
Morris DP; Bance M; van Wijhe RG; Kiefte M; Smith R
Laryngoscope; 2004 Feb; 114(2):305-8. PubMed ID: 14755209
[TBL] [Abstract][Full Text] [Related]
18. 3D-printed custom ossicular prosthesis - methodology of design and LDV measurements in a cadaver study.
Sokołowski J; Orłowski A; Lachowska M; Gosiewska A; Biecek P; Bartoszewicz R; Niemczyk K
Otolaryngol Pol; 2023 Feb; 77(2):1-5. PubMed ID: 36806471
[TBL] [Abstract][Full Text] [Related]
19. Ossiculoplasty using the black hydroxylapatite hybrid ossicular replacement prostheses.
Macias JD; Glasscock ME; Widick MH; Schall DG; Haynes DS; Josey AF
Am J Otol; 1995 Nov; 16(6):718-21. PubMed ID: 8572132
[TBL] [Abstract][Full Text] [Related]
20. Is cartilage interposition required for ossiculoplasty with titanium prostheses?
Pringle MB; Sunkaraneni VS; Tann N
Otol Neurotol; 2014 Mar; 35(3):482-8. PubMed ID: 24492139
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]