188 related articles for article (PubMed ID: 21903487)
1. Novel conductometric biosensor based on three-enzyme system for selective determination of heavy metal ions.
Soldatkin OO; Kucherenko IS; Pyeshkova VM; Kukla AL; Jaffrezic-Renault N; El'skaya AV; Dzyadevych SV; Soldatkin AP
Bioelectrochemistry; 2012 Feb; 83():25-30. PubMed ID: 21903487
[TBL] [Abstract][Full Text] [Related]
2. Heavy metal determination by biosensors based on enzyme immobilised by electropolymerisation.
Malitesta C; Guascito MR
Biosens Bioelectron; 2005 Feb; 20(8):1643-7. PubMed ID: 15626621
[TBL] [Abstract][Full Text] [Related]
3. Invertase inhibition based electrochemical sensor for the detection of heavy metal ions in aqueous system: Application of ultra-microelectrode to enhance sucrose biosensor's sensitivity.
Bagal-Kestwal D; Karve MS; Kakade B; Pillai VK
Biosens Bioelectron; 2008 Dec; 24(4):657-64. PubMed ID: 18667298
[TBL] [Abstract][Full Text] [Related]
4. Fabrication of sucrose biosensor based on single mode planar optical waveguide using co-immobilized plant invertase and GOD.
Bagal DS; Vijayan A; Aiyer RC; Karekar RN; Karve MS
Biosens Bioelectron; 2007 Jun; 22(12):3072-9. PubMed ID: 17314040
[TBL] [Abstract][Full Text] [Related]
5. New glucose biosensor based on glucose oxidase-immobilized gelatin film coated electrodes.
Sungur S; Emregül E; Günendi G; Numanoğlu Y
J Biomater Appl; 2004 Apr; 18(4):265-77. PubMed ID: 15070514
[TBL] [Abstract][Full Text] [Related]
6. Using silver nanoparticle to enhance current response of biosensor.
Ren X; Meng X; Chen D; Tang F; Jiao J
Biosens Bioelectron; 2005 Sep; 21(3):433-7. PubMed ID: 16076432
[TBL] [Abstract][Full Text] [Related]
7. Experimental platform to study heavy metal ion-enzyme interactions and amperometric inhibitive assay of Ag+ based on solution state and immobilized glucose oxidase.
Chen C; Xie Q; Wang L; Qin C; Xie F; Yao S; Chen J
Anal Chem; 2011 Apr; 83(7):2660-6. PubMed ID: 21391572
[TBL] [Abstract][Full Text] [Related]
8. Development of conductometric biosensor array for simultaneous determination of maltose, lactose, sucrose and glucose.
Soldatkin OO; Peshkova VM; Saiapina OY; Kucherenko IS; Dudchenko OY; Melnyk VG; Vasylenko OD; Semenycheva LM; Soldatkin AP; Dzyadevych SV
Talanta; 2013 Oct; 115():200-7. PubMed ID: 24054580
[TBL] [Abstract][Full Text] [Related]
9. A novel urea conductometric biosensor based on zeolite immobilized urease.
Kirdeciler SK; Soy E; Oztürk S; Kucherenko I; Soldatkin O; Dzyadevych S; Akata B
Talanta; 2011 Sep; 85(3):1435-41. PubMed ID: 21807206
[TBL] [Abstract][Full Text] [Related]
10. A novel conductometric biosensor based on hexokinase for determination of adenosine triphosphate.
Kucherenko IS; Kucherenko DY; Soldatkin OO; Lagarde F; Dzyadevych SV; Soldatkin AP
Talanta; 2016 Apr; 150():469-75. PubMed ID: 26838432
[TBL] [Abstract][Full Text] [Related]
11. A biosensor for the determination of amylase activity.
Zajoncová L; Jílek M; Beranová V; Pec P
Biosens Bioelectron; 2004 Sep; 20(2):240-5. PubMed ID: 15308227
[TBL] [Abstract][Full Text] [Related]
12. Amperometric Detection of Aqueous Silver Ions by Inhibition of Glucose Oxidase Immobilized on Nitrogen-Doped Carbon Nanotube Electrodes.
Rust IM; Goran JM; Stevenson KJ
Anal Chem; 2015 Jul; 87(14):7250-7. PubMed ID: 26079664
[TBL] [Abstract][Full Text] [Related]
13. Chemical modification of a nanocrystalline TiO2 film for efficient electric connection of glucose oxidase.
Sousa CP; Polo AS; Torresi RM; de Torresi SI; Alves WA
J Colloid Interface Sci; 2010 Jun; 346(2):442-7. PubMed ID: 20381058
[TBL] [Abstract][Full Text] [Related]
14. Comparative study of conductometric glucose biosensor based on gold and on magnetic nanoparticles.
Nouira W; Maaref A; Elaissari H; Vocanson F; Siadat M; Jaffrezic-Renault N
Mater Sci Eng C Mater Biol Appl; 2013 Jan; 33(1):298-303. PubMed ID: 25428075
[TBL] [Abstract][Full Text] [Related]
15. Fabrication of a glucose biosensor based on inserted barrel plating gold electrodes.
Hsu CT; Chung HH; Tsai DM; Fang MY; Hsiao HC; Zen JM
Anal Chem; 2009 Jan; 81(1):515-8. PubMed ID: 19046070
[TBL] [Abstract][Full Text] [Related]
16. A sensitive and stable biosensor based on the direct electrochemistry of glucose oxidase assembled layer-by-layer at the multiwall carbon nanotube-modified electrode.
Deng C; Chen J; Nie Z; Si S
Biosens Bioelectron; 2010 Sep; 26(1):213-9. PubMed ID: 20620040
[TBL] [Abstract][Full Text] [Related]
17. Development and optimization of a novel conductometric bi-enzyme biosensor for L-arginine determination.
Saiapina OY; Dzyadevych SV; Jaffrezic-Renault N; Soldatkin OP
Talanta; 2012 Apr; 92():58-64. PubMed ID: 22385808
[TBL] [Abstract][Full Text] [Related]
18. A novel biosensor based on glucose oxidase for activity determination of α - amylase.
Altug C; Mengulluoglu U; Kurt E; Kaya S; Dinckaya E
Artif Cells Blood Substit Immobil Biotechnol; 2011 Oct; 39(5):298-303. PubMed ID: 21574907
[TBL] [Abstract][Full Text] [Related]
19. A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes.
Kang X; Mai Z; Zou X; Cai P; Mo J
Anal Biochem; 2007 Oct; 369(1):71-9. PubMed ID: 17678866
[TBL] [Abstract][Full Text] [Related]
20. Mediator-free amperometric glucose biosensor based on glucose oxidase entrapped in poly(vinyl alcohol) matrix.
Guascito MR; Chirizzi D; Malitesta C; Mazzotta E
Analyst; 2011 Jan; 136(1):164-73. PubMed ID: 20877902
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]