BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 21906823)

  • 1. Cochlear implant electrode array misplaced in Hyrtl's fissure.
    Mouzali A; Ouennoughi K; Haraoubia MS; Zemirli O; Triglia JM
    Int J Pediatr Otorhinolaryngol; 2011 Nov; 75(11):1459-62. PubMed ID: 21906823
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The misplaced cochlear implant electrode array.
    Mehanna AM; Gamaleldin OA; Fathalla MF
    Int J Pediatr Otorhinolaryngol; 2019 Feb; 117():96-104. PubMed ID: 30579097
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An unusual occurrence in cochlear implantation surgery: misplaced electrode.
    Ramalingam R; Ramalingam KK; Padmaja HS
    J Laryngol Otol; 2009 Jan; 123(1):e4. PubMed ID: 18980706
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Foreign body reaction after cochlear implantation.
    Lim HJ; Lee ES; Park HY; Park K; Choung YH
    Int J Pediatr Otorhinolaryngol; 2011 Nov; 75(11):1455-8. PubMed ID: 21880376
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hyrtl's fissures in cochlear implant surgery.
    Xie C; Harris R
    Cochlear Implants Int; 2021 Mar; 22(2):116-120. PubMed ID: 32967593
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intracochlear misdirected implantation of a cochlear implant.
    Tange RA; Grolman W; Maat A
    Acta Otolaryngol; 2006 Jun; 126(6):650-2. PubMed ID: 16720451
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hyrtl's fissure.
    Rich PM; Graham J; Phelps PD
    Otol Neurotol; 2002 Jul; 23(4):476-82. PubMed ID: 12170149
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cochlear implantation in children with anomalous cochleovestibular anatomy.
    Papsin BC
    Laryngoscope; 2005 Jan; 115(1 Pt 2 Suppl 106):1-26. PubMed ID: 15626926
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Magnetic resonance imaging versus computed tomography in pre-operative evaluation of cochlear implant candidates with congenital hearing loss.
    Sennaroglu L; Saatci I; Aralasmak A; Gursel B; Turan E
    J Laryngol Otol; 2002 Oct; 116(10):804-10. PubMed ID: 12437835
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Complications and pitfalls of cochlear implantation in otosclerosis: a 6-year follow-up cohort study.
    Sainz M; Garcia-Valdecasas J; Ballesteros JM
    Otol Neurotol; 2009 Dec; 30(8):1044-8. PubMed ID: 19395988
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Methods for evaluation of perimodiolar ci electrode arrays in human temporal bones].
    Richter B; Aschendorff A; Nagursky H; Schipper J; Laszig R; Klenzner T
    Laryngorhinootologie; 2005 Jan; 84(1):42-50. PubMed ID: 15647977
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Identification and revision of a displaced cochlear implant electrode in the internal auditory canal.
    Todt I; Rademacher G; Ernst A
    Cochlear Implants Int; 2013 Sep; 14(4):236-9. PubMed ID: 23510683
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Improving audiologic performance with partial insertion of a compressed array despite intracochlear retention of four electrodes during revision cochlear implant surgery: A case report.
    Côté M; Trudel M; Philippon D; Bussières R
    Cochlear Implants Int; 2015 Jan; 16(1):57-60. PubMed ID: 24950700
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transmastoid labyrinthotomy approach for cochlear implantation in a common cavity malformation: a case report.
    Zarandy MM
    Ear Nose Throat J; 2008 Jun; 87(6):E1-3. PubMed ID: 18561106
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Endocochlear inflammation in cochlear implant users: case report and literature review.
    Benatti A; Castiglione A; Trevisi P; Bovo R; Rosignoli M; Manara R; Martini A
    Int J Pediatr Otorhinolaryngol; 2013 Jun; 77(6):885-93. PubMed ID: 23578804
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cochlear implant electrode array misplacement: a cautionary case report.
    Muzzi E; Boscolo-Rizzo P; Santarelli R; Beltrame MA
    J Laryngol Otol; 2012 Apr; 126(4):414-7. PubMed ID: 22293438
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Elimination of facial nerve stimulation by reimplantation in cochlear implant subjects.
    Battmer R; Pesch J; Stöver T; Lesinski-Schiedat A; Lenarz M; Lenarz T
    Otol Neurotol; 2006 Oct; 27(7):918-22. PubMed ID: 17006341
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preoperative cochlear implant imaging: is magnetic resonance imaging enough?
    Ellul S; Shelton C; Davidson HC; Harnsberger HR
    Am J Otol; 2000 Jul; 21(4):528-33. PubMed ID: 10912699
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Complications and clinical analysis of 416 consecutive cochlear implantations.
    Qiu J; Chen Y; Tan P; Chen J; Han Y; Gao L; Lu Y; Du B
    Int J Pediatr Otorhinolaryngol; 2011 Sep; 75(9):1143-6. PubMed ID: 21741711
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Combining perimodiolar electrode placement and atraumatic insertion properties in cochlear implantation -- fact or fantasy?
    Adunka OF; Pillsbury HC; Kiefer J
    Acta Otolaryngol; 2006 May; 126(5):475-82. PubMed ID: 16698696
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.