210 related articles for article (PubMed ID: 21921672)
1. Development of an electronic manometer for intrapleural pressure monitoring.
Krenke R; Guć M; Grabczak EM; Michnikowski M; Pałko KJ; Chazan R; Gólczewski T
Respiration; 2011; 82(4):377-85. PubMed ID: 21921672
[TBL] [Abstract][Full Text] [Related]
2. Pleural manometry: technique and clinical implications.
Doelken P; Huggins JT; Pastis NJ; Sahn SA
Chest; 2004 Dec; 126(6):1764-9. PubMed ID: 15596671
[TBL] [Abstract][Full Text] [Related]
3. Comparison of pleural pressure measuring instruments.
Lee HJ; Yarmus L; Kidd D; Amador RO; Akulian J; Gilbert C; Hughes A; Thompson RE; Arias S; Feller-Kopman D
Chest; 2014 Oct; 146(4):1007-1012. PubMed ID: 24853674
[TBL] [Abstract][Full Text] [Related]
4. Pleural manometry-historical background, rationale for use and methods of measurement.
Zielinska-Krawczyk M; Krenke R; Grabczak EM; Light RW
Respir Med; 2018 Mar; 136():21-28. PubMed ID: 29501243
[TBL] [Abstract][Full Text] [Related]
5. The relationship between pleural pressures and changes in pulmonary function after therapeutic thoracentesis.
Light RW; Stansbury DW; Brown SE
Am Rev Respir Dis; 1986 Apr; 133(4):658-61. PubMed ID: 3963629
[TBL] [Abstract][Full Text] [Related]
6. A novel model used to compare water-perfused and solid-state anorectal manometry.
Florisson JM; Coolen JC; Bissett IP; Plank LD; Parry BR; Menzi E; Merrie AE
Tech Coloproctol; 2006 Mar; 10(1):17-20. PubMed ID: 16528488
[TBL] [Abstract][Full Text] [Related]
7. Patterns of pleural pressure amplitude and respiratory rate changes during therapeutic thoracentesis.
Zielinska-Krawczyk M; Grabczak EM; Michnikowski M; Zielinski K; Korczynski P; Stecka A; Golczewski T; Krenke R
BMC Pulm Med; 2018 Feb; 18(1):36. PubMed ID: 29444649
[TBL] [Abstract][Full Text] [Related]
8. Routine monitoring with pleural manometry during therapeutic large-volume thoracentesis to prevent pleural-pressure-related complications: a multicentre, single-blind randomised controlled trial.
Lentz RJ; Lerner AD; Pannu JK; Merrick CM; Roller L; Walston C; Valenti S; Goddard T; Chen H; Huggins JT; Rickman OB; Yarmus L; Psallidas I; Rahman NM; Light RW; Maldonado F
Lancet Respir Med; 2019 May; 7(5):447-455. PubMed ID: 30772283
[TBL] [Abstract][Full Text] [Related]
9. Pleural manometry in patients with pleural diseases - the usefulness in clinical practice.
Grabczak EM; Krenke R; Zielinska-Krawczyk M; Light RW
Respir Med; 2018 Dec; 145():230-236. PubMed ID: 29402510
[TBL] [Abstract][Full Text] [Related]
10. [A design and study of a novel electronic device for cuff-pressure monitoring].
Wang S; Li W; Li W; Song D; Chen D; Duan J; Li C; Li G
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2017 Jun; 29(6):551-555. PubMed ID: 28625247
[TBL] [Abstract][Full Text] [Related]
11. Bayesian analysis using continuous likelihood ratios for identifying pleural exudates.
Porcel JM; Peña JM; Vicente de Vera C; Esquerda A; Vives M; Light RW
Respir Med; 2006 Nov; 100(11):1960-5. PubMed ID: 16626953
[TBL] [Abstract][Full Text] [Related]
12. A new method for performing continuous manometry during pleural effusion drainage.
Salamonsen M; Ware R; Fielding D
Respiration; 2014; 88(1):61-6. PubMed ID: 24820119
[TBL] [Abstract][Full Text] [Related]
13. Neonatal resuscitation 3: manometer use in a model of face mask ventilation.
O'Donnell CP; Davis PG; Lau R; Dargaville PA; Doyle LW; Morley CJ
Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F397-400. PubMed ID: 15871988
[TBL] [Abstract][Full Text] [Related]
14. Pleural manometry.
Huggins JT; Doelken P
Clin Chest Med; 2006 Jun; 27(2):229-40. PubMed ID: 16716815
[TBL] [Abstract][Full Text] [Related]
15. [Reliability of blood pressure measurements; comparison of an electronic meter and a mercury manometer in family practice].
van Doorn BA; van der Does E; Lubsen J; Rijsterborgh H
Ned Tijdschr Geneeskd; 1990 Aug; 134(34):1646-50. PubMed ID: 2215707
[TBL] [Abstract][Full Text] [Related]
16. Measurement of pleural pressure during therapeutic thoracentesis.
Villena V; López-Encuentra A; Pozo F; De-Pablo A; Martín-Escribano P
Am J Respir Crit Care Med; 2000 Oct; 162(4 Pt 1):1534-8. PubMed ID: 11029373
[TBL] [Abstract][Full Text] [Related]
17. Accurate compartment pressure measurement using the Intervenous Alarm Control (IVAC) Pump. Report of a technique.
Uppal GS; Smith RC; Sherk HH; Mooar P
J Orthop Trauma; 1992; 6(1):87-9. PubMed ID: 1556629
[TBL] [Abstract][Full Text] [Related]
18. The reliability of measurement of tissue pressure in compartment syndrome.
Hammerberg EM; Whitesides TE; Seiler JG
J Orthop Trauma; 2012 Jan; 26(1):24-31; discussion 32. PubMed ID: 21918480
[TBL] [Abstract][Full Text] [Related]
19. [Digital patient record for remote monitoring of intraocular pressure, blood pressure and serum glucose].
Jürgens C; Antal S; Heydenreich F; Sell C; Tost F
Klin Monbl Augenheilkd; 2006 Sep; 223(9):757-64. PubMed ID: 16986087
[TBL] [Abstract][Full Text] [Related]
20. Development and performance characterization of a new standard mercury manometer.
Akram HM; Maqsood M; Rashid H
Rev Sci Instrum; 2007 Jul; 78(7):075101. PubMed ID: 17672787
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]