These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 2192433)

  • 21. Has the time arrived to replace the quick prothrombin time test for monitoring oral anticoagulant therapy?
    Jackson CM; Esnouf MP
    Clin Chem; 2005 Mar; 51(3):483-5. PubMed ID: 15738512
    [No Abstract]   [Full Text] [Related]  

  • 22. Mathematical derivative applied to international normalised ratio and analytical variations in oral anticoagulant therapy control.
    Introcaso G; Cuboni A; Ratto A; Foieni F
    Haemostasis; 2000; 30(6):281-9. PubMed ID: 11356996
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Point-of-care monitoring of oral anticoagulation therapy in children. Comparison of the CoaguChek XS system with venous INR and venous INR using an International Reference Thromboplastin preparation (rTF/95).
    Greenway A; Ignjatovic V; Summerhayes R; Newall F; Burgess J; DeRosa L; Monagle P
    Thromb Haemost; 2009 Jul; 102(1):159-65. PubMed ID: 19572081
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Discrepant sensitivity of thromboplastin reagents to clotting factor levels explored by the prothrombin time in patients on stable oral anticoagulant treatment: impact on the international normalized ratio system.
    Testa S; Morstabilini G; Fattorini A; Galli L; Denti N; D'Angelo A
    Haematologica; 2002 Dec; 87(12):1265-73. PubMed ID: 12495900
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Standardized prothrombin time determinations and optimal anticoagulant therapy].
    Jespersen J; Hansen MS; Dyerberg J; Ingerslev J; Jensen G; Jørgensen M; Laursen B; Nielsen JD; Svendsen TL
    Ugeskr Laeger; 1991 Jan; 153(5):355-60. PubMed ID: 1994562
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Standardization of the prothrombin time for monitoring orally administered anticoagulant therapy with use of the international normalized ratio system.
    Nichols WL; Bowie EJ
    Mayo Clin Proc; 1993 Sep; 68(9):897-8. PubMed ID: 8371608
    [No Abstract]   [Full Text] [Related]  

  • 27. [Inter-institute variations in International Normalized Ratio and thrombotest].
    Nozawa T; Hayashi S; Naiki S; Niiya K; Asanoi H; Inoue H
    J Cardiol; 1998 Aug; 32(2):89-94. PubMed ID: 9752617
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Quality control and oral anticoagulation.
    Preston FE
    Thromb Haemost; 1995 Jul; 74(1):515-20. PubMed ID: 8578516
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The use of reference plasmas in the control of oral anticoagulant therapy.
    Miale JB
    Scand J Haematol Suppl; 1980; 37():21-33. PubMed ID: 6941439
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants.
    Horsti J
    Haematologica; 2001 Aug; 86(8):851-5. PubMed ID: 11522542
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A comparison of INRs determined with a whole blood prothrombin time device and two international reference preparations for thromboplastin.
    van den Besselaar AM
    Thromb Haemost; 2000 Sep; 84(3):410-2. PubMed ID: 11019963
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The calibration of rabbit tissue thromboplastins: experience of the Dutch Reference Laboratory for anticoagulant control.
    van den Besselaar AM; Hermans J; van der Velde EA; Bussemaker-Verduyn den Boer E; van Halem-Visser LP; Jansen-Grüter R; Loeliger EA
    J Biol Stand; 1986 Oct; 14(4):305-17. PubMed ID: 3558415
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Standardization of coagulation tests.
    Opartkiattikul N
    Southeast Asian J Trop Med Public Health; 1999; 30 Suppl 3():79-85. PubMed ID: 10926265
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Highly sensitive thromboplastins do not improve INR precision.
    Ng VL; Valdes-Camin R; Gottfried EL; Echaves SA; Stead AG; Ebert RF
    Am J Clin Pathol; 1998 Mar; 109(3):338-46. PubMed ID: 9495209
    [TBL] [Abstract][Full Text] [Related]  

  • 35. ASHP therapeutic position statement on the use of the International Normalized Ratio system to monitor oral anticoagulant therapy.
    Am J Health Syst Pharm; 1995 Mar; 52(5):529-31. PubMed ID: 7606561
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Use of INR to assess degree of anticoagulation in patients who have dental procedures.
    Steinberg MJ; Moores JF
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 1995 Aug; 80(2):175-7. PubMed ID: 7552881
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [The international normalization ratio in the monitoring of oral anticoagulant therapy].
    Sansores-García L; Majluf-Cruz AS; Vargas-Vorácková F; Labardini-Méndez J
    Rev Invest Clin; 1993; 45(5):463-7. PubMed ID: 8134728
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Medical liability risk avoidance: a case for adopting the International Normalized Ratio (INR) system.
    Kline SS; Atkins MO
    Am J Manag Care; 1997 Jan; 3(1):59-63. PubMed ID: 10169250
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Evaluation of frozen plasma calibrants for enhanced standardization of the international normalized ratio (INR): a multi-center study.
    Adcock DM; Johnston M
    Thromb Haemost; 2002 Jan; 87(1):74-9. PubMed ID: 11848460
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Preanalytical variables and off-site blood collection: influences on the results of the prothrombin time/international normalized ratio test and implications for monitoring of oral anticoagulant therapy.
    van Geest-Daalderop JH; Mulder AB; Boonman-de Winter LJ; Hoekstra MM; van den Besselaar AM
    Clin Chem; 2005 Mar; 51(3):561-8. PubMed ID: 15650035
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.