These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
113 related articles for article (PubMed ID: 2192483)
21. Micellar electrokinetic capillary chromatography of benzodiazepines in human urine. Schafroth M; Thormann W; Allemann D Electrophoresis; 1994 Jan; 15(1):72-8. PubMed ID: 8143683 [TBL] [Abstract][Full Text] [Related]
22. Evaluation of abalone β-glucuronidase substitution in current urine hydrolysis procedures. Malik-Wolf B; Vorce S; Holler J; Bosy T J Anal Toxicol; 2014 Apr; 38(3):171-6. PubMed ID: 24488113 [TBL] [Abstract][Full Text] [Related]
23. Commentary on: Dou C, Bournique J, Zinda M, Gnezda M, Nally A, Salamone S. Comparison of rates of hydrolysis of lorazepam-glucuronide, oxazepam-glucuronide and temazepam-glucuronide catalyzed by E. coli beta-glucuronidase using the on-line benzodiazepine screening immunoassay on the Roche/Hitachi 917 analyzer. O'Neal CL; Poklis A J Forensic Sci; 2002 Mar; 47(2):427-8. PubMed ID: 11908630 [No Abstract] [Full Text] [Related]
24. Urinary screening for adinazolam and its major metabolites by the Emit d.a.u. and FPIA benzodiazepine assays with confirmation by HPLC. Fraser AD; Isner AF; Bryan W J Anal Toxicol; 1993; 17(7):427-31. PubMed ID: 8309217 [TBL] [Abstract][Full Text] [Related]
25. LC-MS/MS analysis of 13 benzodiazepines and metabolites in urine, serum, plasma, and meconium. Marin SJ; McMillin GA Methods Mol Biol; 2010; 603():89-105. PubMed ID: 20077062 [TBL] [Abstract][Full Text] [Related]
26. Detecting benzodiazepines: immunoassays compared with negative chemical ionization gas chromatography/mass spectrometry. Fitzgerald RL; Rexin DA; Herold DA Clin Chem; 1994 Mar; 40(3):373-80. PubMed ID: 8131270 [TBL] [Abstract][Full Text] [Related]
27. Evaluation of the EMIT Tox enzyme immunoassay for toxicological analysis of benzodiazepines in serum. Pegon Y; Pourcher E; Vallon JJ J Anal Toxicol; 1982; 6(1):1-3. PubMed ID: 7043087 [TBL] [Abstract][Full Text] [Related]
28. Interference of common household chemicals in immunoassay methods for drugs of abuse. Warner A Clin Chem; 1989 Apr; 35(4):648-51. PubMed ID: 2539273 [TBL] [Abstract][Full Text] [Related]
29. Determination of benzodiazepines in human urine and plasma with solvent modified solid phase micro extraction and gas chromatography; rationalisation of method development using experimental design strategies. Reubsaet KJ; Ragnar Norli H; Hemmersbach P; Rasmussen KE J Pharm Biomed Anal; 1998 Dec; 18(4-5):667-80. PubMed ID: 9919968 [TBL] [Abstract][Full Text] [Related]
30. Quantitation of benzodiazepines in urine, serum, plasma, and meconium by LC-MS-MS. Marin SJ; Coles R; Merrell M; McMillin GA J Anal Toxicol; 2008 Sep; 32(7):491-8. PubMed ID: 18713517 [TBL] [Abstract][Full Text] [Related]
31. Enzymatic digestion, solid-phase extraction, and gas chromatography/mass spectrometry of derivatized intact oxazepam in urine. Langner JG; Gan BK; Liu RH; Baugh LD; Chand P; Weng JL; Edwards C; Walia AS Clin Chem; 1991 Sep; 37(9):1595-601. PubMed ID: 1893596 [TBL] [Abstract][Full Text] [Related]
32. Detectability of designer benzodiazepines in CEDIA, EMIT II Plus, HEIA, and KIMS II immunochemical screening assays. Pettersson Bergstrand M; Helander A; Hansson T; Beck O Drug Test Anal; 2017 Apr; 9(4):640-645. PubMed ID: 27366870 [TBL] [Abstract][Full Text] [Related]
33. Comparison of the rates of hydrolysis of lorazepam-glucuronide, oxazepam-glucuronide and tamazepam-glucuronide catalyzed by E. coli beta-D-glucuronidase using the on-line benzodiazepine screening immunoassay on the Roche/Hitachi 917 analyzer. Dou C; Bournique JS; Zinda MK; Gnezda M; McNally AJ; Salamone SJ J Forensic Sci; 2001 Mar; 46(2):335-40. PubMed ID: 11305436 [TBL] [Abstract][Full Text] [Related]
34. [Application of extraction freezing for analysis of 1,4-benzodiazepines in urine]. Bekhterev VN; Gavrilova SN; Maslakov IV Sud Med Ekspert; 2007; 50(2):32-5. PubMed ID: 17520905 [TBL] [Abstract][Full Text] [Related]
35. Fluorometric screening method for detecting benzodiazepines in blood and urine. Valentour JC; Monforte JR; Lorenzo B; Sunshine I Clin Chem; 1975 Dec; 21(13):1976-9. PubMed ID: 1192593 [TBL] [Abstract][Full Text] [Related]
36. Benzodiazepines identified by capillary gas chromatography-mass spectrometry, with specific ion screening used to detect benzophenone derivatives. Jones CE; Wians FH; Martinez LA; Merritt GJ Clin Chem; 1989 Jul; 35(7):1394-8. PubMed ID: 2667799 [TBL] [Abstract][Full Text] [Related]
37. Analysis of oxazepam in urine using solid-phase extraction and high-performance liquid chromatography with fluorescence detection by post-column derivatization. Berrueta LA; Gallo B; Vicente F J Chromatogr; 1993 Jul; 616(2):344-8. PubMed ID: 8376518 [TBL] [Abstract][Full Text] [Related]
38. New fluorescence polarization immunoassays for analysis of barbiturates and benzodiazepines in serum and urine: performance characteristics. Schwenzer KS; Pearlman R; Tsilimidos M; Salamone SJ; Cannon RC; Wong SH; Gock SB; Jentzen JJ J Anal Toxicol; 2000; 24(8):726-32. PubMed ID: 11110029 [TBL] [Abstract][Full Text] [Related]