These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 21927739)

  • 1. A FRET-based indicator for imaging mitochondrial zinc ions.
    Sreenath K; Allen JR; Davidson MW; Zhu L
    Chem Commun (Camb); 2011 Nov; 47(42):11730-2. PubMed ID: 21927739
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A fluorescent indicator for imaging lysosomal zinc(II) with Förster resonance energy transfer (FRET)-enhanced photostability and a narrow band of emission.
    Sreenath K; Yuan Z; Allen JR; Davidson MW; Zhu L
    Chemistry; 2015 Jan; 21(2):867-74. PubMed ID: 25382395
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clear evidence of fluorescence resonance energy transfer in gas-phase ions.
    Dashtiev M; Azov V; Frankevich V; Scharfenberg L; Zenobi R
    J Am Soc Mass Spectrom; 2005 Sep; 16(9):1481-1487. PubMed ID: 16023366
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new mitochondrial fluorescent zinc sensor.
    Sensi SL; Ton-That D; Weiss JH; Rothe A; Gee KR
    Cell Calcium; 2003 Sep; 34(3):281-4. PubMed ID: 12887975
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A ratiometric and targetable fluorescent sensor for quantification of mitochondrial zinc ions.
    Xue L; Li G; Yu C; Jiang H
    Chemistry; 2012 Jan; 18(4):1050-4. PubMed ID: 22190110
    [No Abstract]   [Full Text] [Related]  

  • 6. FRET-based ratiometric fluorescent probes for selective Fe3+ sensing and their applications in mitochondria.
    Chen WD; Gong WT; Ye ZQ; Lin Y; Ning GL
    Dalton Trans; 2013 Jul; 42(28):10093-6. PubMed ID: 23728488
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A TP-FRET-based two-photon fluorescent probe for ratiometric visualization of endogenous sulfur dioxide derivatives in mitochondria of living cells and tissues.
    Yang X; Zhou Y; Zhang X; Yang S; Chen Y; Guo J; Li X; Qing Z; Yang R
    Chem Commun (Camb); 2016 Aug; 52(67):10289-92. PubMed ID: 27469474
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fluorescence resonance energy transfer-based ratiometric fluorescent probe for detection of Zn(2+) using a dual-emission silica-coated quantum dots mixture.
    Wu L; Guo QS; Liu YQ; Sun QJ
    Anal Chem; 2015 May; 87(10):5318-23. PubMed ID: 25932651
    [TBL] [Abstract][Full Text] [Related]  

  • 9. eZinCh-2: A Versatile, Genetically Encoded FRET Sensor for Cytosolic and Intraorganelle Zn(2+) Imaging.
    Hessels AM; Chabosseau P; Bakker MH; Engelen W; Rutter GA; Taylor KM; Merkx M
    ACS Chem Biol; 2015 Sep; 10(9):2126-34. PubMed ID: 26151333
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intracellular Zinc Quantification by Fluorescence Imaging with a FRET System.
    Shu Y; Zheng N; Zheng AQ; Guo TT; Yu YL; Wang JH
    Anal Chem; 2019 Mar; 91(6):4157-4163. PubMed ID: 30793593
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Efficient fluorescence resonance energy transfer-based ratiometric fluorescent cellular imaging probe for Zn(2+) using a rhodamine spirolactam as a trigger.
    Han ZX; Zhang XB; Li Z; Gong YJ; Wu XY; Jin Z; He CM; Jian LX; Zhang J; Shen GL; Yu RQ
    Anal Chem; 2010 Apr; 82(8):3108-13. PubMed ID: 20334436
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Multifunctional self-assembled polymeric nanoprobes for FRET-based ratiometric detection of mitochondrial H2O2 in living cells.
    Qiao J; Liu Z; Tian Y; Wu M; Niu Z
    Chem Commun (Camb); 2015 Feb; 51(17):3641-4. PubMed ID: 25642908
    [TBL] [Abstract][Full Text] [Related]  

  • 13. FRET-based sensor for imaging chromium(III) in living cells.
    Zhou Z; Yu M; Yang H; Huang K; Li F; Yi T; Huang C
    Chem Commun (Camb); 2008 Aug; (29):3387-9. PubMed ID: 18633498
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-depth fluorescence imaging using a two-photon FRET system for mitochondrial pH in live cells and tissues.
    Chang MJ; Kim K; Park KS; Kang JS; Lim CS; Kim HM; Kang C; Lee MH
    Chem Commun (Camb); 2018 Dec; 54(96):13531-13534. PubMed ID: 30431633
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A FRET-Based Near-Infrared Fluorescent Probe for Ratiometric Detection of Cysteine in Mitochondria.
    Xia S; Zhang Y; Fang M; Mikesell L; Steenwinkel TE; Wan S; Phillips T; Luck RL; Werner T; Liu H
    Chembiochem; 2019 Aug; 20(15):1986-1994. PubMed ID: 31197917
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monitoring mitochondrial membrane potential by FRET: Development of fluorescent probes enabling ΔΨ
    Sun J; Tian M; Lin W
    Anal Chim Acta; 2020 Feb; 1097():196-203. PubMed ID: 31910960
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A mitochondria-targeted fluorescent probe for ratiometric detection of endogenous sulfur dioxide derivatives in cancer cells.
    Li DP; Wang ZY; Cao XJ; Cui J; Wang X; Cui HZ; Miao JY; Zhao BX
    Chem Commun (Camb); 2016 Feb; 52(13):2760-3. PubMed ID: 26757700
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A ratiometric fluorescent sensor with a large Stokes shift for imaging zinc ions in living cells.
    Xue L; Liu C; Jiang H
    Chem Commun (Camb); 2009 Mar; (9):1061-3. PubMed ID: 19225636
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A FRET-based ratiometric fluorescent probe to detect cysteine metabolism in mitochondria.
    Han X; Zhai Z; Yang X; Zhang D; Tang J; Zhu J; Zhu X; Ye Y
    Org Biomol Chem; 2020 Feb; 18(7):1487-1492. PubMed ID: 32026925
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A mitochondrial-targeted two-photon probe for zinc ion.
    Masanta G; Lim CS; Kim HJ; Han JH; Kim HM; Cho BR
    J Am Chem Soc; 2011 Apr; 133(15):5698-700. PubMed ID: 21449534
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.