These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 21927822)

  • 1. Sensitivity of patient-specific vertebral finite element model from low dose imaging to material properties and loading conditions.
    Travert C; Jolivet E; Sapin-de Brosses E; Mitton D; Skalli W
    Med Biol Eng Comput; 2011 Dec; 49(12):1355-61. PubMed ID: 21927822
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Osteoporosis changes the amount of vertebral trabecular bone at risk of fracture but not the vertebral load distribution.
    Homminga J; Weinans H; Gowin W; Felsenberg D; Huiskes R
    Spine (Phila Pa 1976); 2001 Jul; 26(14):1555-61. PubMed ID: 11462085
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prediction of the vertebral strength using a finite element model derived from low-dose biplanar imaging: benefits of subject-specific material properties.
    Sapin-de Brosses E; Jolivet E; Travert C; Mitton D; Skalli W
    Spine (Phila Pa 1976); 2012 Feb; 37(3):E156-62. PubMed ID: 22290213
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prediction of incident vertebral fracture using CT-based finite element analysis.
    Allaire BT; Lu D; Johannesdottir F; Kopperdahl D; Keaveny TM; Jarraya M; Guermazi A; Bredella MA; Samelson EJ; Kiel DP; Anderson DE; Demissie S; Bouxsein ML
    Osteoporos Int; 2019 Feb; 30(2):323-331. PubMed ID: 30306225
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Density-Dependent Material and Failure Criteria Equations Highly Affect the Accuracy and Precision of QCT/FEA-Based Predictions of Osteoporotic Vertebral Fracture Properties.
    Prado M; Rezaei A; Giambini H
    Ann Biomed Eng; 2021 Feb; 49(2):663-672. PubMed ID: 32820381
    [TBL] [Abstract][Full Text] [Related]  

  • 6. QCT-based finite element models predict human vertebral strength in vitro significantly better than simulated DEXA.
    Dall'Ara E; Pahr D; Varga P; Kainberger F; Zysset P
    Osteoporos Int; 2012 Feb; 23(2):563-72. PubMed ID: 21344244
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An in silico parametric model of vertebrae trabecular bone based on density and microstructural parameters to assess risk of fracture in osteoporosis.
    Amjadi Kashani MR; Nikkhoo M; Khalaf K; Firoozbakhsh K; Arjmand N; Razmjoo A; Parnianpour M
    Proc Inst Mech Eng H; 2014 Dec; 228(12):1281-95. PubMed ID: 25515229
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cortical and trabecular load sharing in the human vertebral body.
    Eswaran SK; Gupta A; Adams MF; Keaveny TM
    J Bone Miner Res; 2006 Feb; 21(2):307-14. PubMed ID: 16418787
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Finite element modeling of the human thoracolumbar spine.
    Liebschner MA; Kopperdahl DL; Rosenberg WS; Keaveny TM
    Spine (Phila Pa 1976); 2003 Mar; 28(6):559-65. PubMed ID: 12642762
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of the intervertebral disc on vertebral bone strength prediction: a finite-element study.
    Anitha DP; Baum T; Kirschke JS; Subburaj K
    Spine J; 2020 Apr; 20(4):665-671. PubMed ID: 31841703
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calibration of the mechanical properties in a finite element model of a lumbar vertebra under dynamic compression up to failure.
    Garo A; Arnoux PJ; Wagnac E; Aubin CE
    Med Biol Eng Comput; 2011 Dec; 49(12):1371-9. PubMed ID: 21947796
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Restoring geometric and loading alignment of the thoracic spine with a vertebral compression fracture: effects of balloon (bone tamp) inflation and spinal extension.
    Gaitanis IN; Carandang G; Phillips FM; Magovern B; Ghanayem AJ; Voronov LI; Havey RM; Zindrick MR; Hadjipavlou AG; Patwardhan AG
    Spine J; 2005; 5(1):45-54. PubMed ID: 15653084
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prediction of vertebral strength under loading conditions occurring in activities of daily living using a computed tomography-based nonlinear finite element method.
    Matsumoto T; Ohnishi I; Bessho M; Imai K; Ohashi S; Nakamura K
    Spine (Phila Pa 1976); 2009 Jun; 34(14):1464-9. PubMed ID: 19525837
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High resolution quantitative computed tomography-based assessment of trabecular microstructure and strength estimates by finite-element analysis of the spine, but not DXA, reflects vertebral fracture status in men with glucocorticoid-induced osteoporosis.
    Graeff C; Marin F; Petto H; Kayser O; Reisinger A; Peña J; Zysset P; Glüer CC
    Bone; 2013 Feb; 52(2):568-77. PubMed ID: 23149277
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fabric-based Tsai-Wu yield criteria for vertebral trabecular bone in stress and strain space.
    Wolfram U; Gross T; Pahr DH; Schwiedrzik J; Wilke HJ; Zysset PK
    J Mech Behav Biomed Mater; 2012 Nov; 15():218-28. PubMed ID: 23159819
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A probabilistic finite element analysis of the stresses in the augmented vertebral body after vertebroplasty.
    Rohlmann A; Boustani HN; Bergmann G; Zander T
    Eur Spine J; 2010 Sep; 19(9):1585-95. PubMed ID: 20361339
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Apparent- and Tissue-Level Yield Behaviors of L4 Vertebral Trabecular Bone and Their Associations with Microarchitectures.
    Gong H; Wang L; Fan Y; Zhang M; Qin L
    Ann Biomed Eng; 2016 Apr; 44(4):1204-23. PubMed ID: 26104807
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Specimen-specific vertebral fracture modeling: a feasibility study using the extended finite element method.
    Giambini H; Qin X; Dragomir-Daescu D; An KN; Nassr A
    Med Biol Eng Comput; 2016 Apr; 54(4):583-93. PubMed ID: 26239163
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intrinsic mechanical properties of trabecular calcaneus determined by finite-element models using 3D synchrotron microtomography.
    Follet H; Peyrin F; Vidal-Salle E; Bonnassie A; Rumelhart C; Meunier PJ
    J Biomech; 2007; 40(10):2174-83. PubMed ID: 17196599
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of Augmentation Material Stiffness on Adjacent Vertebrae after Osteoporotic Vertebroplasty Using Finite Element Analysis with Different Loading Methods.
    Cho AR; Cho SB; Lee JH; Kim KH
    Pain Physician; 2015 Nov; 18(6):E1101-10. PubMed ID: 26606023
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.