BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

301 related articles for article (PubMed ID: 21928653)

  • 1. Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate.
    Bertelsen A; Lorenzen EL; Brink C
    Med Phys; 2011 Aug; 38(8):4802-10. PubMed ID: 21928653
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The impact of continuously-variable dose rate VMAT on beam stability, MLC positioning, and overall plan dosimetry.
    Boylan C; McWilliam A; Johnstone E; Rowbottom C
    J Appl Clin Med Phys; 2012 Nov; 13(6):4023. PubMed ID: 23149797
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis of direct clinical consequences of MLC positional errors in volumetric-modulated arc therapy using 3D dosimetry system.
    Nithiyanantham K; Mani GK; Subramani V; Mueller L; Palaniappan KK; Kataria T
    J Appl Clin Med Phys; 2015 Sep; 16(5):296–305. PubMed ID: 26699311
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of MLC leaf positioning accuracy for static and dynamic IMRT treatments using DAVID in vivo dosimetric system.
    Karagoz G; Zorlu F; Yeginer M; Yildiz D; Ozyigit G
    J Appl Clin Med Phys; 2016 Mar; 17(2):14-23. PubMed ID: 27074451
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Commissioning of volumetric modulated arc therapy (VMAT).
    Bedford JL; Warrington AP
    Int J Radiat Oncol Biol Phys; 2009 Feb; 73(2):537-45. PubMed ID: 19147018
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Single Arc Volumetric Modulated Arc Therapy of head and neck cancer.
    Bertelsen A; Hansen CR; Johansen J; Brink C
    Radiother Oncol; 2010 May; 95(2):142-8. PubMed ID: 20188427
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures.
    Mavroidis P; Ferreira BC; Shi C; Lind BK; Papanikolaou N
    Phys Med Biol; 2007 Jul; 52(13):3817-36. PubMed ID: 17664579
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Interplay effect on a 6-MV flattening-filter-free linear accelerator with high dose rate and fast multi-leaf collimator motion treating breast and lung phantoms.
    Netherton T; Li Y; Nitsch P; Shaitelman S; Balter P; Gao S; Klopp A; Muruganandham M; Court L
    Med Phys; 2018 Jun; 45(6):2369-2376. PubMed ID: 29611210
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A generalized inverse planning tool for volumetric-modulated arc therapy.
    Cao D; Afghan MK; Ye J; Chen F; Shepard DM
    Phys Med Biol; 2009 Nov; 54(21):6725-38. PubMed ID: 19841516
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT.
    Nelms BE; Opp D; Zhang G; Moros E; Feygelman V
    Med Phys; 2014 Jun; 41(6):061704. PubMed ID: 24877799
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Electromagnetic guided couch and multileaf collimator tracking on a TrueBeam accelerator.
    Hansen R; Ravkilde T; Worm ES; Toftegaard J; Grau C; Macek K; Poulsen PR
    Med Phys; 2016 May; 43(5):2387. PubMed ID: 27147350
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of three commercial dosimetric systems in detecting clinically significant VMAT delivery errors.
    Arumugam S; Xing A; Young T; Thwaites D; Holloway L
    Phys Med; 2016 Oct; 32(10):1238-1244. PubMed ID: 27717741
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the Impact of the Linac MLC and Gantry Sag in volumetric modulated arc therapy.
    Milan T; Grogan G; Ebert MA; Rowshanfarzad P
    Med Phys; 2019 May; 46(5):1984-1994. PubMed ID: 30870581
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Time-resolved dose distributions to moving targets during volumetric modulated arc therapy with and without dynamic MLC tracking.
    Ravkilde T; Keall PJ; Grau C; Høyer M; Poulsen PR
    Med Phys; 2013 Nov; 40(11):111723. PubMed ID: 24320431
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging.
    Zwan BJ; Barnes MP; Hindmarsh J; Lim SB; Lovelock DM; Fuangrod T; O'Connor DJ; Keall PJ; Greer PB
    Med Phys; 2017 Aug; 44(8):3909-3922. PubMed ID: 28564208
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of leaf motion constraints on IMAT plan quality, deliver accuracy, and efficiency.
    Chen F; Rao M; Ye JS; Shepard DM; Cao D
    Med Phys; 2011 Nov; 38(11):6106-18. PubMed ID: 22047375
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A novel method for routine quality assurance of volumetric-modulated arc therapy.
    Wang Q; Dai J; Zhang K
    Med Phys; 2013 Oct; 40(10):101712. PubMed ID: 24089902
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the Elekta Agility MLC performance using high-resolution log files.
    Kabat CN; Defoor DL; Myers P; Kirby N; Rasmussen K; Saenz DL; Mavroidis P; Papanikolaou N; Stathakis S
    Med Phys; 2019 Mar; 46(3):1397-1407. PubMed ID: 30702748
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Texture analysis on the fluence map to evaluate the degree of modulation for volumetric modulated arc therapy.
    Park SY; Kim IH; Ye SJ; Carlson J; Park JM
    Med Phys; 2014 Nov; 41(11):111718. PubMed ID: 25370632
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Time-resolved dose reconstruction by motion encoding of volumetric modulated arc therapy fields delivered with and without dynamic multi-leaf collimator tracking.
    Ravkilde T; Keall PJ; Grau C; Høyer M; Poulsen PR
    Acta Oncol; 2013 Oct; 52(7):1497-503. PubMed ID: 23984811
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.