These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 21931387)

  • 1. Two-dimensional gratings-based phase-contrast imaging using a conventional x-ray tube.
    Sato G; Kondoh T; Itoh H; Handa S; Yamaguchi K; Nakamura T; Nagai K; Ouchi C; Teshima T; Setomoto Y; Den T
    Opt Lett; 2011 Sep; 36(18):3551-3. PubMed ID: 21931387
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Two-dimensional grating-based X-ray phase-contrast imaging using Fourier transform phase retrieval.
    Itoh H; Nagai K; Sato G; Yamaguchi K; Nakamura T; Kondoh T; Ouchi C; Teshima T; Setomoto Y; Den T
    Opt Express; 2011 Feb; 19(4):3339-46. PubMed ID: 21369156
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Moiré deflectometry using the Talbot-Lau interferometer as refraction diagnostic for high energy density plasmas at energies below 10 keV.
    Valdivia MP; Stutman D; Finkenthal M
    Rev Sci Instrum; 2014 Jul; 85(7):073702. PubMed ID: 25085141
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sparse phase-stepping in two-dimensional x-ray phase contrast imaging.
    Kondoh T; Date T; Yamaguchi K; Nagai K; Sato G; Handa S; Den T; Itoh H; Nakamura T
    Appl Opt; 2014 Apr; 53(12):2602-10. PubMed ID: 24787585
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Laboratory-based X-ray phase-imaging scanner using Talbot-Lau interferometer for non-destructive testing.
    Bachche S; Nonoguchi M; Kato K; Kageyama M; Koike T; Kuribayashi M; Momose A
    Sci Rep; 2017 Jul; 7(1):6711. PubMed ID: 28751744
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A phase demodulation method for two-dimensional grating-based X-ray interferometry.
    Nagai K
    Philos Trans A Math Phys Eng Sci; 2014 Mar; 372(2010):20130034. PubMed ID: 24470416
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Four-dimensional X-ray phase tomography with Talbot interferometry and white synchrotron radiation: dynamic observation of a living worm.
    Momose A; Yashiro W; Harasse S; Kuwabara H
    Opt Express; 2011 Apr; 19(9):8423-32. PubMed ID: 21643093
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Projection angle dependence in grating-based X-ray dark-field imaging of ordered structures.
    Bayer F; Zabler S; Brendel C; Pelzer G; Rieger J; Ritter A; Weber T; Michel T; Anton G
    Opt Express; 2013 Aug; 21(17):19922-33. PubMed ID: 24105538
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Talbot-Lau x-ray deflectometry phase-retrieval methods for electron density diagnostics in high-energy density experiments.
    Valdivia MP; Stutman D; Stoeckl C; Mileham C; Begishev IA; Bromage J; Regan SP
    Appl Opt; 2018 Jan; 57(2):138-145. PubMed ID: 29328157
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Soft-tissue phase-contrast tomography with an x-ray tube source.
    Bech M; Jensen TH; Feidenhans'l R; Bunk O; David C; Pfeiffer F
    Phys Med Biol; 2009 May; 54(9):2747-53. PubMed ID: 19369710
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A sensitive x-ray phase contrast technique for rapid imaging using a single phase grid analyzer.
    Morgan KS; Modregger P; Irvine SC; Rutishauser S; Guzenko VA; Stampanoni M; David C
    Opt Lett; 2013 Nov; 38(22):4605-8. PubMed ID: 24322085
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The fractional Talbot effect in differential x-ray phase-contrast imaging for extended and polychromatic x-ray sources.
    Engelhardt M; Kottler C; Bunk O; David C; Schroer C; Baumann J; Schuster M; Pfeiffer F
    J Microsc; 2008 Oct; 232(1):145-57. PubMed ID: 19017212
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Grating interferometer based scanning setup for hard X-ray phase contrast imaging.
    Kottler C; Pfeiffer F; Bunk O; Grünzweig C; David C
    Rev Sci Instrum; 2007 Apr; 78(4):043710. PubMed ID: 17477673
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A preclinical Talbot-Lau prototype for x-ray dark-field imaging of human-sized objects.
    Hauke C; Bartl P; Leghissa M; Ritschl L; Sutter SM; Weber T; Zeidler J; Freudenberger J; Mertelmeier T; Radicke M; Michel T; Anton G; Meinel FG; Baehr A; Auweter S; Bondesson D; Gaass T; Dinkel J; Reiser M; Hellbach K
    Med Phys; 2018 Jun; 45(6):2565-2571. PubMed ID: 29582440
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Two dimensional x-ray phase imaging using single grating interferometer with embedded x-ray targets.
    Morimoto N; Fujino S; Yamazaki A; Ito Y; Hosoi T; Watanabe H; Shimura T
    Opt Express; 2015 Jun; 23(13):16582-8. PubMed ID: 26191670
    [TBL] [Abstract][Full Text] [Related]  

  • 16. X-ray bi-prism interferometry-A design study of proposed novel hardware.
    Gullberg GT; Shrestha U; Kim SJW; Seo Y; Fuller M
    Med Phys; 2021 Oct; 48(10):6508-6523. PubMed ID: 34554568
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube.
    Honda C; Ohara H
    Eur J Radiol; 2008 Dec; 68(3 Suppl):S69-72. PubMed ID: 18584984
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A phase demodulation method with high spatial resolution for two-dimensional single-shot X-ray Talbot interferometry.
    Nagai K; Sato G; Date T; Handa S; Yamaguchi K; Kondoh T; Nakamura T
    Opt Express; 2014 Feb; 22(4):4316-28. PubMed ID: 24663755
    [TBL] [Abstract][Full Text] [Related]  

  • 19. X-ray phase contrast imaging by compact Talbot-Lau interferometer with a single transmission grating.
    Morimoto N; Fujino S; Ohshima K; Harada J; Hosoi T; Watanabe H; Shimura T
    Opt Lett; 2014 Aug; 39(15):4297-300. PubMed ID: 25078161
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source.
    Donath T; Pfeiffer F; Bunk O; Groot W; Bednarzik M; Grünzweig C; Hempel E; Popescu S; Hoheisel M; David C
    Rev Sci Instrum; 2009 May; 80(5):053701. PubMed ID: 19485510
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.