These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 21934335)

  • 1. In vitro comparison of noise levels produced by different CPAP generators.
    Kirchner L; Wald M; Jeitler V; Pollak A
    Neonatology; 2012; 101(2):95-100. PubMed ID: 21934335
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Variety of expiratory resistance between different continuous positive airway pressure devices for preterm infants.
    Wald M; Kribs A; Jeitler V; Lirsch D; Pollak A; Kirchner L
    Artif Organs; 2011 Jan; 35(1):22-8. PubMed ID: 20618229
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Noise exposure is increased with neonatal helmet CPAP in comparison with conventional nasal CPAP.
    Trevisanuto D; Camiletti L; Doglioni N; Cavallin F; Udilano A; Zanardo V
    Acta Anaesthesiol Scand; 2011 Jan; 55(1):35-8. PubMed ID: 21077846
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Noise levels of neonatal high-flow nasal cannula devices--an in-vitro study.
    König K; Stock EL; Jarvis M
    Neonatology; 2013; 103(4):264-7. PubMed ID: 23466653
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effects of imposed resistance on tidal volume with 5 neonatal nasal continuous positive airway pressure systems.
    Cook SE; Fedor KL; Chatburn RL
    Respir Care; 2010 May; 55(5):544-8. PubMed ID: 20420723
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Return of neonatal CPAP resistance - the Medijet device family examined using in vitro flow simulations.
    Falk M; Donaldsson S; Jonsson B; Drevhammar T
    Acta Paediatr; 2017 Nov; 106(11):1760-1766. PubMed ID: 28715132
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of seven infant continuous positive airway pressure systems using simulated neonatal breathing.
    Drevhammar T; Nilsson K; Zetterström H; Jonsson B
    Pediatr Crit Care Med; 2012 Mar; 13(2):e113-9. PubMed ID: 21946854
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Are high flow nasal cannulae noisier than bubble CPAP for preterm infants?
    Roberts CT; Dawson JA; Alquoka E; Carew PJ; Donath SM; Davis PG; Manley BJ
    Arch Dis Child Fetal Neonatal Ed; 2014 Jul; 99(4):F291-5. PubMed ID: 24625433
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Which continuous positive airway pressure system is best for the preterm infant with respiratory distress syndrome?
    Jane Pillow J
    Clin Perinatol; 2012 Sep; 39(3):483-96. PubMed ID: 22954264
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Exposure to noise during continuous positive airway pressure: influence of interfaces and delivery systems.
    Cavaliere F; Conti G; Costa R; Spinazzola G; Proietti R; Sciuto A; Masieri S
    Acta Anaesthesiol Scand; 2008 Jan; 52(1):52-6. PubMed ID: 17996003
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noise levels during nCPAP are flow-dependent but not device-dependent.
    Karam O; Donatiello C; Van Lancker E; Chritin V; Pfister RE; Rimensberger PC
    Arch Dis Child Fetal Neonatal Ed; 2008 Mar; 93(2):F132-4. PubMed ID: 18089628
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nasal masks or binasal prongs for delivering continuous positive airway pressure in preterm neonates-a randomised trial.
    Chandrasekaran A; Thukral A; Jeeva Sankar M; Agarwal R; Paul VK; Deorari AK
    Eur J Pediatr; 2017 Mar; 176(3):379-386. PubMed ID: 28091776
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect on work of breathing of different continuous positive airway pressure devices evaluated in a premature neonatal lung model.
    Nikischin W; Petridis M; Noeske J; Spengler D; von Bismarck P
    Pediatr Crit Care Med; 2011 Nov; 12(6):e376-82. PubMed ID: 21499172
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Nursing Care Guidelines for prevention of nasal breakdown in neonates receiving nasal CPAP.
    McCoskey L
    Adv Neonatal Care; 2008 Apr; 8(2):116-24. PubMed ID: 18418209
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pharyngeal pressure value using two continuous positive airway pressure devices.
    Colnaghi M; Matassa PG; Fumagalli M; Messina D; Mosca F
    Arch Dis Child Fetal Neonatal Ed; 2008 Jul; 93(4):F302-4. PubMed ID: 18334615
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pharyngeal pressure in preterm infants receiving nasal continuous positive airway pressure.
    De Paoli AG; Lau R; Davis PG; Morley CJ
    Arch Dis Child Fetal Neonatal Ed; 2005 Jan; 90(1):F79-81. PubMed ID: 15613585
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A randomized controlled trial of post-extubation bubble continuous positive airway pressure versus Infant Flow Driver continuous positive airway pressure in preterm infants with respiratory distress syndrome.
    Gupta S; Sinha SK; Tin W; Donn SM
    J Pediatr; 2009 May; 154(5):645-50. PubMed ID: 19230906
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noise levels during neonatal helmet CPAP.
    Trevisanuto D; Camiletti L; Udilano A; Doglioni N; Zanardo V
    Arch Dis Child Fetal Neonatal Ed; 2008 Sep; 93(5):F396-7. PubMed ID: 18723784
    [No Abstract]   [Full Text] [Related]  

  • 19. Comparison of two flow generators with a noninvasive ventilator to deliver continuous positive airway pressure: a test lung study.
    Fu C; Caruso P; Lucatto JJ; de Paula Schettino GP; de Souza R; Carvalho CR
    Intensive Care Med; 2005 Nov; 31(11):1587-91. PubMed ID: 16222519
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The nursing care of the infant receiving bubble CPAP therapy.
    Bonner KM; Mainous RO
    Adv Neonatal Care; 2008 Apr; 8(2):78-95; quiz 96-7. PubMed ID: 18418205
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.