These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

169 related articles for article (PubMed ID: 21938526)

  • 1. An evaluation and comparison of intraventricular, intraparenchymal, and fluid-coupled techniques for intracranial pressure monitoring in patients with severe traumatic brain injury.
    Vender J; Waller J; Dhandapani K; McDonnell D
    J Clin Monit Comput; 2011 Aug; 25(4):231-6. PubMed ID: 21938526
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo accuracy of two intraparenchymal intracranial pressure monitors.
    Lescot T; Reina V; Le Manach Y; Boroli F; Chauvet D; Boch AL; Puybasset L
    Intensive Care Med; 2011 May; 37(5):875-9. PubMed ID: 21359608
    [TBL] [Abstract][Full Text] [Related]  

  • 3. External Ventricular Drains versus Intraparenchymal Intracranial Pressure Monitors in Traumatic Brain Injury: A Prospective Observational Study.
    Liu H; Wang W; Cheng F; Yuan Q; Yang J; Hu J; Ren G
    World Neurosurg; 2015 May; 83(5):794-800. PubMed ID: 25541084
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Discrepancy Between Internal and External Intracranial Pressure Transducers: Quantification of an Old Source of Error in EVDs?
    Darrow D; Lee-Norris A; Larson A; Samadani U; Netoff TI
    World Neurosurg; 2020 Jan; 133():e18-e25. PubMed ID: 31394360
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Association Patterns of Simultaneous Intraventricular and Intraparenchymal Intracranial Pressure Measurements.
    Mahdavi ZK; Olson DM; Figueroa SA
    Neurosurgery; 2016 Oct; 79(4):561-7. PubMed ID: 27244464
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cerebral intraparenchymal pressure monitoring in non-traumatic coma: clinical evaluation of a new fibreoptic device.
    Tasker RC; Matthew DJ
    Neuropediatrics; 1991 Feb; 22(1):47-9. PubMed ID: 2038429
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Regional pressure and temperature variations across the injured human brain: comparisons between paired intraparenchymal and ventricular measurements.
    Childs C; Shen L
    Crit Care; 2015 Jun; 19(1):267. PubMed ID: 26100266
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical comparison of the Spiegelberg parenchymal transducer and ventricular fluid pressure.
    Chambers IR; Siddique MS; Banister K; Mendelow AD
    J Neurol Neurosurg Psychiatry; 2001 Sep; 71(3):383-5. PubMed ID: 11511715
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intracranial pressure-monitoring systems in children with traumatic brain injury: combining therapeutic and diagnostic tools.
    Exo J; Kochanek PM; Adelson PD; Greene S; Clark RS; Bayir H; Wisniewski SR; Bell MJ
    Pediatr Crit Care Med; 2011 Sep; 12(5):560-5. PubMed ID: 20625341
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Inductive passive sensor for intraparenchymal and intraventricular monitoring of intracranial pressure.
    Behfar MH; Abada E; Sydanheimo L; Goldman K; Fleischman AJ; Gupta N; Ukkonen L; Roy S
    Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():1950-1954. PubMed ID: 28268710
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [SIMULTANEOUS MEASUREMENT OF INTRAVENTRICULAR AND PARENCHYMAL INTRACRANIAL PRESSURE IN PATIENTS WITH SEVERE TRAUMA BRAIN INJURY].
    Oshorov AV; Popugaev KA; Savin IA; Potapov AA
    Anesteziol Reanimatol; 2016; 61(1):37-9. PubMed ID: 27192853
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pressure-controlled drainage of cerebrospinal fluid: clinical experience with a new type of ventricular catheter (Ventcontrol MTC)and an integrated Piezo-resistive sensor at its tip: technical note.
    Piek J; Raes P
    Neurosurgery; 1996 Jan; 38(1):216-8. PubMed ID: 8747976
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intracranial pressure monitoring techniques.
    Ghajar J
    New Horiz; 1995 Aug; 3(3):395-9. PubMed ID: 7496747
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of Intracranial Pressure and Pressure Reactivity Index Obtained Through Pressure Measurements in the Ventricle and in the Parenchyma During and Outside Cerebrospinal Fluid Drainage Episodes in a Manipulation-Free Patient Setting.
    Klein SP; Bruyninckx D; Callebaut I; Depreitere B
    Acta Neurochir Suppl; 2018; 126():287-290. PubMed ID: 29492576
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automated intracranial pressure-controlled cerebrospinal fluid external drainage with LiquoGuard.
    Linsler S; Schmidtke M; Steudel WI; Kiefer M; Oertel J
    Acta Neurochir (Wien); 2013 Aug; 155(8):1589-94; discussion 1594-5. PubMed ID: 23188469
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The Brain Trauma Foundation. The American Association of Neurological Surgeons. The Joint Section on Neurotrauma and Critical Care. Recommendations for intracranial pressure monitoring technology.
    J Neurotrauma; 2000; 17(6-7):497-506. PubMed ID: 10937892
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experimental evaluation of the Spiegelberg intracranial pressure and intracranial compliance monitor. Technical note.
    Yau YH; Piper IR; Clutton RE; Whittle IR
    J Neurosurg; 2000 Dec; 93(6):1072-7. PubMed ID: 11117854
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ventricular Drainage Catheters versus Intracranial Parenchymal Catheters for Intracranial Pressure Monitoring-Based Management of Traumatic Brain Injury: A Systematic Review and Meta-Analysis.
    Volovici V; Huijben JA; Ercole A; Stocchetti N; Dirven CMF; van der Jagt M; Steyerberg EW; Lingsma HF; Menon DK; Maas AIR; Haitsma IK
    J Neurotrauma; 2019 Apr; 36(7):988-995. PubMed ID: 30251919
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraparenchymal vs extracranial ventricular drain intracranial pressure monitors in traumatic brain injury: less is more?
    Kasotakis G; Michailidou M; Bramos A; Chang Y; Velmahos G; Alam H; King D; de Moya MA
    J Am Coll Surg; 2012 Jun; 214(6):950-7. PubMed ID: 22541986
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of a novel noninvasive ICP monitoring device in patients undergoing invasive ICP monitoring: preliminary results.
    Ganslandt O; Mourtzoukos S; Stadlbauer A; Sommer B; Rammensee R
    J Neurosurg; 2018 Jun; 128(6):1653-1660. PubMed ID: 28784032
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.