106 related articles for article (PubMed ID: 21939215)
1. Variable volume loading method: a convenient and rapid method for measuring the initial emittable concentration and partition coefficient of formaldehyde and other aldehydes in building materials.
Xiong J; Yan W; Zhang Y
Environ Sci Technol; 2011 Dec; 45(23):10111-6. PubMed ID: 21939215
[TBL] [Abstract][Full Text] [Related]
2. C-history method: rapid measurement of the initial emittable concentration, diffusion and partition coefficients for formaldehyde and VOCs in building materials.
Xiong J; Yao Y; Zhang Y
Environ Sci Technol; 2011 Apr; 45(8):3584-90. PubMed ID: 21428433
[TBL] [Abstract][Full Text] [Related]
3. Impact of temperature on the initial emittable concentration of formaldehyde in building materials: experimental observation.
Xiong J; Zhang Y
Indoor Air; 2010 Dec; 20(6):523-9. PubMed ID: 21070377
[TBL] [Abstract][Full Text] [Related]
4. A rapid and accurate method, ventilated chamber C-history method, of measuring the emission characteristic parameters of formaldehyde/VOCs in building materials.
Huang S; Xiong J; Zhang Y
J Hazard Mater; 2013 Oct; 261():542-9. PubMed ID: 23994652
[TBL] [Abstract][Full Text] [Related]
5. Comparison of analytical techniques for the determination of aldehydes in test chambers.
Salthammer T; Mentese S
Chemosphere; 2008 Nov; 73(8):1351-6. PubMed ID: 18722643
[TBL] [Abstract][Full Text] [Related]
6. Estimates of parameters for formaldehyde emission model from plywood panel under various temperature and relative humidity conditions.
Su C; Ming H; Yang Y; Ma W; Li H; Li L
J Environ Sci Health A Tox Hazard Subst Environ Eng; 2019; 54(1):48-55. PubMed ID: 30230958
[TBL] [Abstract][Full Text] [Related]
7. Impact of temperature on the ratio of initial emittable concentration to total concentration for formaldehyde in building materials: theoretical correlation and validation.
Huang S; Xiong J; Zhang Y
Environ Sci Technol; 2015 Feb; 49(3):1537-44. PubMed ID: 25563933
[TBL] [Abstract][Full Text] [Related]
8. A new method for determining the initial mobile formaldehyde concentrations, partition coefficients, and diffusion coefficients of dry building materials.
Wang X; Zhang Y
J Air Waste Manag Assoc; 2009 Jul; 59(7):819-25. PubMed ID: 19645266
[TBL] [Abstract][Full Text] [Related]
9. A study on VOC source and sink behavior in porous building materials - analytical model development and assessment.
Lee CS; Haghighat F; Ghaly WS
Indoor Air; 2005 Jun; 15(3):183-96. PubMed ID: 15865618
[TBL] [Abstract][Full Text] [Related]
10. Formaldehyde emission behavior of building materials: on-site measurements and modeling approach to predict indoor air pollution.
Bourdin D; Mocho P; Desauziers V; Plaisance H
J Hazard Mater; 2014 Sep; 280():164-73. PubMed ID: 25151239
[TBL] [Abstract][Full Text] [Related]
11. A rapid and robust method to determine the key parameters of formaldehyde emissions from building and vehicle cabin materials: Principle, multi-source application and exposure assessment.
Wang H; Wang H; Xiong J; Huang S; Koutrakis P
J Hazard Mater; 2022 May; 430():128422. PubMed ID: 35149496
[TBL] [Abstract][Full Text] [Related]
12. Comparison of formaldehyde emission from building finishing materials at various temperatures in under heating system; ONDOL.
Kim S; Kim HJ
Indoor Air; 2005 Oct; 15(5):317-25. PubMed ID: 16108904
[TBL] [Abstract][Full Text] [Related]
13. [Measurement of emission rate of formaldehyde and volatile organic compounds(VOCs) from building materials by the small chamber method].
Hori H; Morita I; Otoguro T; Higashi T
J UOEH; 2003 Sep; 25(3):283-94. PubMed ID: 14503040
[TBL] [Abstract][Full Text] [Related]
14. A novel method for measuring the diffusion, partition and convective mass transfer coefficients of formaldehyde and VOC in building materials.
Xiong J; Huang S; Zhang Y
PLoS One; 2012; 7(11):e49342. PubMed ID: 23145156
[TBL] [Abstract][Full Text] [Related]
15. 3D-CFD analysis of diffusion and emission of VOCs in a FLEC cavity.
Zhu Q; Kato S; Murakami S; Ito K
Indoor Air; 2007 Jun; 17(3):178-88. PubMed ID: 17542831
[TBL] [Abstract][Full Text] [Related]
16. Differences in source emission rates of volatile organic compounds in inner-city residences of New York City and Los Angeles.
Sax SN; Bennett DH; Chillrud SN; Kinney PL; Spengler JD
J Expo Anal Environ Epidemiol; 2004; 14 Suppl 1():S95-109. PubMed ID: 15118751
[TBL] [Abstract][Full Text] [Related]
17. Volatile organic compounds concentrations during the construction process in newly-built timber-frame houses: source identification and emission kinetics.
Plaisance H; Vignau-Laulhere J; Mocho P; Sauvat N; Raulin K; Desauziers V
Environ Sci Process Impacts; 2017 May; 19(5):696-710. PubMed ID: 28387778
[TBL] [Abstract][Full Text] [Related]
18. Study of effect of adsorptive building material on formaldehyde concentrations: development of measuring methods and modeling of adsorption phenomena.
Ataka Y; Kato S; Murakami S; Zhu Q; Ito K; Yokota T
Indoor Air; 2004; 14 Suppl 8():51-64. PubMed ID: 15663460
[TBL] [Abstract][Full Text] [Related]
19. [Formaldehyde--public health related aspects of building construction regarding toxicology].
Wegner J; Schlüter G
Schriftenr Ver Wasser Boden Lufthyg; 1995; 95():59-80. PubMed ID: 7777818
[No Abstract] [Full Text] [Related]
20. A simple method for screening emission sources of carbonyl compounds in indoor air.
Yamashita S; Kume K; Horiike T; Honma N; Fusaya M; Ohura T; Amagai T
J Hazard Mater; 2010 Jun; 178(1-3):370-6. PubMed ID: 20149530
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]