  • 1. Racial bias and reproducibility in pulse oximetry among medical and surgical inpatients in general care in the Veterans Health Administration 2013-19: multicenter, retrospective cohort study.
    Valbuena VSM; Seelye S; Sjoding MW; Valley TS; Dickson RP; Gay SE; Claar D; Prescott HC; Iwashyna TJ
    BMJ; 2022 Jul; 378():e069775. PubMed ID: 35793817
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characteristics of pulse oximetry and arterial blood gas in patients with fibrotic interstitial lung disease.
    Donaldson MA; Donohoe K; Assayag D; Durand C; Fisher JH; Johannson K; Kolb M; Lok SD; Manganas H; Marcoux V; Min B; Morisset J; Marinescu DC; Ryerson CJ
    BMJ Open Respir Res; 2024 Mar; 11(1):. PubMed ID: 38479819
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Does nurse use of a standardized flowsheet to document communication with advanced providers provide a mechanism to detect pulse oximetry failures? A retrospective study of electronic health record data.
    Gleason KT; Tran A; Fawzy A; Yan L; Farley H; Garibaldi B; Iwashyna TJ
    Int J Nurs Stud; 2024 Jul; 155():104770. PubMed ID: 38676990
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The incidence of hypoxemia in dogs recovering from general anesthesia detected with pulse-oximetry and related risk factors.
    Piemontese C; Stabile M; Di Bella C; Scardia A; Vicenti C; Acquafredda C; Crovace A; Lacitignola L; Staffieri F
    Vet J; 2024 Jun; 305():106135. PubMed ID: 38750813
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Discrepancy between arterial oxygen saturation and pulse oximetry measurement in a Chinese pediatric patient cohort.
    Chen QC; Shen JJ; Huang YL; Kong R; Xie YM; Wang SS
    Heliyon; 2024 Apr; 10(7):e28336. PubMed ID: 38560171
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pulse Oximetry and Race in Critically Ill Adults.
    Seitz KP; Wang L; Casey JD; Markus SA; Jackson KE; Qian ET; Self WH; Rice TW; Semler MW
    Crit Care Explor; 2022 Sep; 4(9):e0758. PubMed ID: 36128001
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of the predictors and frequency of silent hypoxemia in COVID-19 patients and the gap between pulse oximeter and arterial blood gas levels: A cross-sectional study.
    Fallahi MJ; Pezeshkian F; Ranjbar K; Javaheri R; Shahriarirad R
    Health Care Sci; 2024 Jun; 3(3):172-180. PubMed ID: 38947362
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pulse oximetry for hypoxemia: a warning to users and manufacturers.
    Fanconi S
    Intensive Care Med; 1989; 15(8):540-2. PubMed ID: 2691541
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Pulse oximetry: Role in the COVID-19 patient at home].
    Serrano-Cumplido A; Trillo Calvo E; García Matarín L; Del Río Herrero A; Gamir Ruiz FJ; Molina Escribano F; Velilla Zancada S
    Semergen; 2022; 48(1):70-77. PubMed ID: 33947594
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of pulse oximetry in the detection of hypoxia in liver transplant candidates.
    Mohammad Ali Ghayumi S; Nikeghbalian S; Kakaei F; Nejatollahi MR; Mohammad Taghi Ayatoliahi S
    Hepatogastroenterology; 2011; 58(110-111):1700-2. PubMed ID: 21940332
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Utility of pulse oximetry in the detection of arterial hypoxemia in liver transplant candidates.
    Abrams GA; Sanders MK; Fallon MB
    Liver Transpl; 2002 Apr; 8(4):391-6. PubMed ID: 11965585
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pulse oximeter oxygen saturation in prediction of arterial oxygen saturation in liver transplant candidates.
    Ghayumi SM; Khalafi-Nezhad A; Jowkar Z
    Hepat Mon; 2014 Apr; 14(4):e15449. PubMed ID: 24748894
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension.
    Kohyama T; Moriyama K; Kanai R; Kotani M; Uzawa K; Satoh T; Yorozu T
    PLoS One; 2015; 10(5):e0126979. PubMed ID: 25978517
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of pulse oximetry in the intensive care unit.
    Van de Louw A; Cracco C; Cerf C; Harf A; Duvaldestin P; Lemaire F; Brochard L
    Intensive Care Med; 2001 Oct; 27(10):1606-13. PubMed ID: 11685301
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The accuracy of pulse oximetry in the emergency department.
    Lee WW; Mayberry K; Crapo R; Jensen RL
    Am J Emerg Med; 2000 Jul; 18(4):427-31. PubMed ID: 10919532
    [TBL] [Abstract][Full Text] [Related]  

  • 16.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 17.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 18.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 19.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 2.