These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

375 related articles for article (PubMed ID: 21940564)

  • 1. CT-guided lung biopsies: pleural blood patching reduces the rate of chest tube placement for postbiopsy pneumothorax.
    Wagner JM; Hinshaw JL; Lubner MG; Robbins JB; Kim DH; Pickhardt PJ; Lee FT
    AJR Am J Roentgenol; 2011 Oct; 197(4):783-8. PubMed ID: 21940564
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficacy of manual aspiration immediately after complicated pneumothorax in CT-guided lung biopsy.
    Yamagami T; Kato T; Iida S; Hirota T; Yoshimatsu R; Nishimura T
    J Vasc Interv Radiol; 2005 Apr; 16(4):477-83. PubMed ID: 15802447
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Risk factors influencing chest tube placement among patients with pneumothorax because of CT-guided needle biopsy of the lung.
    Nakamura M; Yoshizako T; Koyama S; Kitagaki H
    J Med Imaging Radiat Oncol; 2011 Oct; 55(5):474-8. PubMed ID: 22008165
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of intraparenchymal blood patch on rates of pneumothorax and pneumothorax requiring chest tube placement after percutaneous lung biopsy.
    Malone LJ; Stanfill RM; Wang H; Fahey KM; Bertino RE
    AJR Am J Roentgenol; 2013 Jun; 200(6):1238-43. PubMed ID: 23701059
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulmonary Intraparenchymal Blood Patching Decreases the Rate of Pneumothorax-Related Complications following Percutaneous CT-Guided Needle Biopsy.
    Graffy P; Loomis SB; Pickhardt PJ; Lubner MG; Kitchin DR; Lee FT; Hinshaw JL
    J Vasc Interv Radiol; 2017 Apr; 28(4):608-613.e1. PubMed ID: 28185770
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors.
    Laurent F; Michel P; Latrabe V; Tunon de Lara M; Marthan R
    AJR Am J Roentgenol; 1999 Apr; 172(4):1049-53. PubMed ID: 10587145
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Role of manual aspiration in treating pneumothorax after computed tomography-guided lung biopsy.
    Yamagami T; Terayama K; Yoshimatsu R; Matsumoto T; Miura H; Nishimura T
    Acta Radiol; 2009 Dec; 50(10):1126-33. PubMed ID: 19922309
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Effect of Needle Gauge on the Risk of Pneumothorax and Chest Tube Placement After Percutaneous Computed Tomographic (CT)-Guided Lung Biopsy.
    Kuban JD; Tam AL; Huang SY; Ensor JE; Philip AS; Chen GJ; Ahrar J; Murthy R; Avritscher R; Madoff DC; Mahvash A; Ahrar K; Wallace MJ; Nachiappan AC; Gupta S
    Cardiovasc Intervent Radiol; 2015 Dec; 38(6):1595-602. PubMed ID: 25920917
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Percutaneous Lung Biopsy with Pleural and Parenchymal Blood Patching: Results and Complications from 1,112 Core Biopsies.
    Zlevor AM; Mauch SC; Knott EA; Pickhardt PJ; Mankowski Gettle L; Mao L; Meyer CA; Hartung MP; Kim DH; Lubner MG; Hinshaw JL; Foltz ML; Ziemlewicz TJ; Lee FT
    J Vasc Interv Radiol; 2021 Sep; 32(9):1319-1327. PubMed ID: 34229043
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The effect of intraparenchymal blood patching on the rate of pneumothorax in patients undergoing percutaneous CT-guided core biopsy of the lung.
    Perl RM; Risse E; Hetzel J; Bösmüller H; Kloth C; Fritz J; Horger M
    Eur J Radiol; 2019 Jul; 116():14-20. PubMed ID: 31153555
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nonclotted Blood Patch Technique Reduces Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsies.
    Clayton JD; Elicker BM; Ordovas KG; Kohi MP; Nguyen J; Naeger DM
    J Thorac Imaging; 2016 Jul; 31(4):243-6. PubMed ID: 27105052
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tract embolization with gelatin sponge slurry for prevention of pneumothorax after percutaneous computed tomography-guided lung biopsy.
    Tran AA; Brown SB; Rosenberg J; Hovsepian DM
    Cardiovasc Intervent Radiol; 2014 Dec; 37(6):1546-53. PubMed ID: 24366313
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung.
    Kazerooni EA; Lim FT; Mikhail A; Martinez FJ
    Radiology; 1996 Feb; 198(2):371-5. PubMed ID: 8596834
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Efficacy of the tract embolization technique with gelatin sponge slurry to reduce pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy.
    Renier H; Gérard L; Lamborelle P; Cousin F
    Cardiovasc Intervent Radiol; 2020 Apr; 43(4):597-603. PubMed ID: 31792589
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Usefulness and limitation of manual aspiration immediately after pneumothorax complicating interventional radiological procedures with the transthoracic approach.
    Yamagami T; Kato T; Hirota T; Yoshimatsu R; Matsumoto T; Nishimura T
    Cardiovasc Intervent Radiol; 2006; 29(6):1027-33. PubMed ID: 16897262
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pneumothorax Incidence with Normal Saline Instillation for Sealing the Needle Track After Computed Tomography-Guided Percutaneous Lung Biopsy.
    Bourgeais G; Frampas E; Liberge R; Nicolas A; Defrance C; Blanc FX; Coudol S; Morla O
    Cardiovasc Intervent Radiol; 2024 May; 47(5):604-612. PubMed ID: 38263525
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax.
    Cox JE; Chiles C; McManus CM; Aquino SL; Choplin RH
    Radiology; 1999 Jul; 212(1):165-8. PubMed ID: 10405737
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Factors influencing pneumothorax rate at lung biopsy: are dwell time and angle of pleural puncture contributing factors?
    Ko JP; Shepard JO; Drucker EA; Aquino SL; Sharma A; Sabloff B; Halpern E; McLoud TC
    Radiology; 2001 Feb; 218(2):491-6. PubMed ID: 11161167
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors.
    Moreland A; Novogrodsky E; Brody L; Durack J; Erinjeri J; Getrajdman G; Solomon S; Yarmohammadi H; Maybody M
    Eur Radiol; 2016 Oct; 26(10):3483-91. PubMed ID: 26787605
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Outpatient management of postbiopsy pneumothorax with small-caliber chest tubes: factors affecting the need for prolonged drainage and additional interventions.
    Gupta S; Hicks ME; Wallace MJ; Ahrar K; Madoff DC; Murthy R
    Cardiovasc Intervent Radiol; 2008; 31(2):342-8. PubMed ID: 18074173
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.