124 related articles for article (PubMed ID: 21945858)
21. A methodological approach to reporting corrected small field relative outputs.
Cranmer-Sargison G; Charles PH; Trapp JV; Thwaites DI
Radiother Oncol; 2013 Dec; 109(3):350-5. PubMed ID: 24183867
[TBL] [Abstract][Full Text] [Related]
22. Implementation and experimental validation of the high dose rate stereotactic treatment mode at Varian accelerators.
Hoffmann L
Acta Oncol; 2009; 48(2):201-8. PubMed ID: 18759143
[TBL] [Abstract][Full Text] [Related]
23. Monte Carlo simulation of the dynamic micro-multileaf collimator of a LINAC Elekta Precise using PENELOPE.
González W; Lallena AM; Alfonso R
Phys Med Biol; 2011 Jun; 56(11):3417-31. PubMed ID: 21572185
[TBL] [Abstract][Full Text] [Related]
24. Calculation of k(Q(clin),Q(msr) ) (f(clin),f(msr) ) for several small detectors and for two linear accelerators using Monte Carlo simulations.
Francescon P; Cora S; Satariano N
Med Phys; 2011 Dec; 38(12):6513-27. PubMed ID: 22149834
[TBL] [Abstract][Full Text] [Related]
25. Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.
Qin Y; Zhong H; Wen N; Snyder K; Huang Y; Chetty IJ
J Appl Clin Med Phys; 2016 Nov; 17(6):379-391. PubMed ID: 27929510
[TBL] [Abstract][Full Text] [Related]
26. A virtual photon source model of an Elekta linear accelerator with integrated mini MLC for Monte Carlo based IMRT dose calculation.
Sikora M; Dohm O; Alber M
Phys Med Biol; 2007 Aug; 52(15):4449-63. PubMed ID: 17634643
[TBL] [Abstract][Full Text] [Related]
27. Evaluation of the IAEA-TRS 483 protocol for the dosimetry of small fields (square and stereotactic cones) using multiple detectors.
Smith CL; Montesari A; Oliver CP; Butler DJ
J Appl Clin Med Phys; 2020 Feb; 21(2):98-110. PubMed ID: 31886615
[TBL] [Abstract][Full Text] [Related]
28. Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system.
Cheng JY; Ning H; Arora BC; Zhuge Y; Miller RW
J Appl Clin Med Phys; 2016 May; 17(3):100-110. PubMed ID: 27167266
[TBL] [Abstract][Full Text] [Related]
29. Determination of zero-field size percent depth doses and tissue maximum ratios for stereotactic radiosurgery and IMRT dosimetry: comparison between experimental measurements and Monte Carlo simulation.
Cheng CW; Cho SH; Taylor M; Das IJ
Med Phys; 2007 Aug; 34(8):3149-57. PubMed ID: 17879776
[TBL] [Abstract][Full Text] [Related]
30. Energy and field size dependence of a silicon diode designed for small-field dosimetry.
Yarahmadi M; Wegener S; Sauer OA
Med Phys; 2017 May; 44(5):1958-1964. PubMed ID: 28273357
[TBL] [Abstract][Full Text] [Related]
31. Small field measurements with a novel silicon position sensitive diode array.
Manolopoulos S; Wojnecki C; Hugtenburg R; Jaafar Sidek MA; Chalmers G; Heyes G; Green S
Phys Med Biol; 2009 Feb; 54(3):485-95. PubMed ID: 19124947
[TBL] [Abstract][Full Text] [Related]
32. Effect of electron contamination of a 6 MV x-ray beam on near surface diode dosimetry.
Edwards CR; Mountford PJ; Moloney AJ
Phys Med Biol; 2006 Dec; 51(24):6471-82. PubMed ID: 17148830
[TBL] [Abstract][Full Text] [Related]
33. [Experimental determination of correction factors of four detectors used in small field radiotherapy].
Ben Salem L; Essadok A; Saidani I; Mahdouani M; Benna M; Mahjoubi K; Besbes M; Benna F
Cancer Radiother; 2018 Feb; 22(1):45-51. PubMed ID: 29290555
[TBL] [Abstract][Full Text] [Related]
34. Density compensated diodes for small field dosimetry: comprehensive testing and implications for design.
Georgiou G; Kumar S; Würfel JU; Underwood TSA; Thompson JM; Hill MA; Rowbottom CG; Fenwick JD
Phys Med Biol; 2020 Aug; 65(15):155011. PubMed ID: 32392539
[TBL] [Abstract][Full Text] [Related]
35. Correction factor measurements for multiple detectors used in small field dosimetry on the Varian Edge radiosurgery system.
Tanny S; Sperling N; Parsai EI
Med Phys; 2015 Sep; 42(9):5370-6. PubMed ID: 26328986
[TBL] [Abstract][Full Text] [Related]
36. Development of a Monte Carlo model for the Brainlab microMLC.
Belec J; Patrocinio H; Verhaegen F
Phys Med Biol; 2005 Mar; 50(5):787-99. PubMed ID: 15798255
[TBL] [Abstract][Full Text] [Related]
37. Monitoring linear accelerator output constancy using the PTW Linacheck.
McDermott GM; Buckle AH
Med Dosim; 2011; 36(1):71-4. PubMed ID: 20346645
[TBL] [Abstract][Full Text] [Related]
38. Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator.
Veselsky T; Novotny J; Pastykova V; Koniarova I
Phys Med; 2017 Dec; 44():66-71. PubMed ID: 29254593
[TBL] [Abstract][Full Text] [Related]
39. Monte Carlo simulated correction factors for output factor measurement with the CyberKnife system-results for new detectors and correction factor dependence on measurement distance and detector orientation.
Francescon P; Kilby W; Satariano N
Phys Med Biol; 2014 Mar; 59(6):N11-7. PubMed ID: 24594929
[TBL] [Abstract][Full Text] [Related]
40. Experimental determination of peripheral doses for different IMRT techniques delivered by a Siemens linear accelerator.
Wiezorek T; Voigt A; Metzger N; Georg D; Schwedas M; Salz H; Wendt TG
Strahlenther Onkol; 2008 Feb; 184(2):73-9. PubMed ID: 18259698
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]