BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 21945858)

  • 41. Evaluation and characterization of parallel plate microchamber's functionalities in small beam dosimetry.
    Lee HR; Pankuch M; Chu JC; Spokas JJ
    Med Phys; 2002 Nov; 29(11):2489-96. PubMed ID: 12462713
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Small fields output factors measurements and correction factors determination for several detectors for a CyberKnife® and linear accelerators equipped with microMLC and circular cones.
    Bassinet C; Huet C; Derreumaux S; Brunet G; Chéa M; Baumann M; Lacornerie T; Gaudaire-Josset S; Trompier F; Roch P; Boisserie G; Clairand I
    Med Phys; 2013 Jul; 40(7):071725. PubMed ID: 23822429
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Small field output correction factors of the microSilicon detector and a deeper understanding of their origin by quantifying perturbation factors.
    Weber C; Kranzer R; Weidner J; Kröninger K; Poppe B; Looe HK; Poppinga D
    Med Phys; 2020 Jul; 47(7):3165-3173. PubMed ID: 32196683
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Measurement and evaluation of inhomogeneity corrections and monitor unit verification for treatment planning.
    Saxena R; Higgins P
    Med Dosim; 2010; 35(1):19-27. PubMed ID: 19931010
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Output factor measurements with multiple detectors in CyberKnife
    Manavalan M; Durai M; Narayanasamy G; Stathakis S; Godson HF; Subramani V
    J Cancer Res Ther; 2021; 17(4):870-874. PubMed ID: 34528534
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Stereotactic fields shaped with a micro-multileaf collimator: systematic characterization of peripheral dose.
    Taylor ML; McDermott LN; Johnston PN; Haynes M; Ackerly T; Kron T; Franich RD
    Phys Med Biol; 2010 Feb; 55(3):873-81. PubMed ID: 20071767
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Head scatter factors for small MV photon fields. Part I: a comparison of phantom types and methodologies.
    McKerracher C; Thwaites DI
    Radiother Oncol; 2007 Nov; 85(2):277-85. PubMed ID: 17983677
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Total scatter factors of small beams: a multidetector and Monte Carlo study.
    Francescon P; Cora S; Cavedon C
    Med Phys; 2008 Feb; 35(2):504-13. PubMed ID: 18383671
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Implementation of in vivo dosimetry with Isorad semiconductor diodes in radiotherapy treatments of the pelvis.
    Rodríguez ML; Abrego E; Pineda A
    Med Dosim; 2008; 33(1):14-21. PubMed ID: 18262118
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code.
    Panettieri V; Duch MA; Jornet N; Ginjaume M; Carrasco P; Badal A; Ortega X; Ribas M
    Phys Med Biol; 2007 Jan; 52(1):303-16. PubMed ID: 17183143
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Field output factors for small fields: A large multicentre study.
    Dufreneix S; Bellec J; Josset S; Vieillevigne L
    Phys Med; 2021 Jan; 81():191-196. PubMed ID: 33465756
    [TBL] [Abstract][Full Text] [Related]  

  • 52. MOSFET detectors in quality assurance of tomotherapy treatments.
    Cherpak A; Studinski RC; Cygler JE
    Radiother Oncol; 2008 Feb; 86(2):242-50. PubMed ID: 18037519
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A practical and theoretical definition of very small field size for radiotherapy output factor measurements.
    Charles PH; Cranmer-Sargison G; Thwaites DI; Crowe SB; Kairn T; Knight RT; Kenny J; Langton CM; Trapp JV
    Med Phys; 2014 Apr; 41(4):041707. PubMed ID: 24694127
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Flattening filter free beams in SBRT and IMRT: dosimetric assessment of peripheral doses.
    Kragl G; Baier F; Lutz S; Albrich D; Dalaryd M; Kroupa B; Wiezorek T; Knöös T; Georg D
    Z Med Phys; 2011 May; 21(2):91-101. PubMed ID: 20888199
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Field size consistency of nominally matched linacs.
    Kairn T; Asena A; Charles PH; Hill B; Langton CM; Middlebrook ND; Moylan R; Trapp JV
    Australas Phys Eng Sci Med; 2015 Jun; 38(2):289-97. PubMed ID: 26025010
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Monte Carlo commissioning of clinical electron beams using large field measurements.
    O'Shea TP; Sawkey DL; Foley MJ; Faddegon BA
    Phys Med Biol; 2010 Jul; 55(14):4083-105. PubMed ID: 20601775
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The influence of a novel transmission detector on 6 MV x-ray beam characteristics.
    Venkataraman S; Malkoske KE; Jensen M; Nakonechny KD; Asuni G; McCurdy BM
    Phys Med Biol; 2009 May; 54(10):3173-83. PubMed ID: 19420428
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Characterization of small-field stereotactic radiosurgery beams with modern detectors.
    Tyler M; Liu PZ; Chan KW; Ralston A; McKenzie DR; Downes S; Suchowerska N
    Phys Med Biol; 2013 Nov; 58(21):7595-608. PubMed ID: 24107592
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Inter-institutional variability of small-field-dosimetry beams among HD120
    Akino Y; Mizuno H; Tanaka Y; Isono M; Masai N; Yamamoto T
    Phys Med Biol; 2018 Oct; 63(20):205018. PubMed ID: 30255847
    [TBL] [Abstract][Full Text] [Related]  

  • 60. SU-E-T-230: Field Factor Verification in Small Fields.
    Jia Y; Zhang H; Desrosiers C; Das I
    Med Phys; 2012 Jun; 39(6Part13):3756. PubMed ID: 28517344
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.