These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 21945858)

  • 61. Monte Carlo calculated correction factors for the PTW microDiamond detector in the Gamma Knife-Model C.
    Barrett JC; Knill C
    Med Phys; 2016 Mar; 43(3):1035-44. PubMed ID: 26936691
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Multi-site evaluation of the Razor stereotactic diode for CyberKnife small field relative dosimetry.
    Russo S; Masi L; Francescon P; Dicarolo P; De Martin E; Frassanito C; Redaelli I; Vigorito S; Stasi M; Mancosu P
    Phys Med; 2019 Sep; 65():40-45. PubMed ID: 31430585
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Evaluating the output stability of LINAC with a reference detector using 3D water phantom.
    Shimozato T; Kojima T; Sakamoto M; Hata Y; Sasaki K; Araki N
    Igaku Butsuri; 2012; 32(4):176-81. PubMed ID: 24568022
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Can small field diode correction factors be applied universally?
    Liu PZ; Suchowerska N; McKenzie DR
    Radiother Oncol; 2014 Sep; 112(3):442-6. PubMed ID: 25441057
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Small field output factors evaluation with a microDiamond detector over 30 Italian centers.
    Russo S; Reggiori G; Cagni E; Clemente S; Esposito M; Falco MD; Fiandra C; Giglioli FR; Marinelli M; Marino C; Masi L; Pimpinella M; Stasi M; Strigari L; Talamonti C; Villaggi E; Mancosu P
    Phys Med; 2016 Dec; 32(12):1644-1650. PubMed ID: 27839775
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Small field detector correction factors kQclin,Qmsr (fclin,fmsr) for silicon-diode and diamond detectors with circular 6 MV fields derived using both empirical and numerical methods.
    O'Brien DJ; León-Vintró L; McClean B
    Med Phys; 2016 Jan; 43(1):411. PubMed ID: 26745934
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Clinical use of diodes and micro-chambers to obtain accurate small field output factor measurements.
    Kairn T; Charles PH; Cranmer-Sargison G; Crowe SB; Langton CM; Thwaites DI; Trapp JV
    Australas Phys Eng Sci Med; 2015 Jun; 38(2):357-67. PubMed ID: 25744538
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Dosimetric characteristics of the small diameter BrainLab™ cones used for stereotactic radiosurgery.
    Khelashvili G; Chu J; Diaz A; Turian J
    J Appl Clin Med Phys; 2012 Jan; 13(1):3610. PubMed ID: 22231212
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Small field diode correction factors derived using an air core fibre optic scintillation dosimeter and EBT2 film.
    Ralston A; Liu P; Warrener K; McKenzie D; Suchowerska N
    Phys Med Biol; 2012 May; 57(9):2587-602. PubMed ID: 22505592
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Small field in-air output factors: the role of miniphantom design and dosimeter type.
    Warrener K; Hug B; Liu P; Ralston A; Ebert MA; McKenzie DR; Suchowerska N
    Med Phys; 2014 Feb; 41(2):021723. PubMed ID: 24506614
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Direct detection of 6 MV x-rays from a medical linear accelerator using a semiconducting polymer diode.
    Mills CA; Chan YF; Intaniwet A; Shkunov M; Nisbet A; Keddie JL; Sellin PJ
    Phys Med Biol; 2013 Jul; 58(13):4471-82. PubMed ID: 23760010
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Verification of representative data for output factors of SRS cones utilizing IAEA TRS 483 recommendations.
    Irmen P; Reft C; Fitzherbert C; Solin L; Hand C
    Phys Med Biol; 2019 Nov; 64(21):215011. PubMed ID: 31556402
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Characterization of an inorganic scintillator for small-field dosimetry in MR-guided radiotherapy.
    Cusumano D; Placidi L; D'Agostino E; Boldrini L; Menna S; Valentini V; De Spirito M; Azario L
    J Appl Clin Med Phys; 2020 Sep; 21(9):244-251. PubMed ID: 32841500
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Measurement of output factors for small photon beams.
    Sauer OA; Wilbert J
    Med Phys; 2007 Jun; 34(6):1983-8. PubMed ID: 17654901
    [TBL] [Abstract][Full Text] [Related]  

  • 75. A multi-institutional evaluation of small field output factor determination following the recommendations of IAEA/AAPM TRS-483.
    Lechner W; Alfonso R; Arib M; Huq MS; Ismail A; Kinhikar R; Lárraga-Gutiérrez JM; Mani KR; Maphumulo N; Sauer OA; Shoeir S; Suriyapee S; Christaki K
    Med Phys; 2022 Aug; 49(8):5537-5550. PubMed ID: 35717637
    [TBL] [Abstract][Full Text] [Related]  

  • 76. [Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector].
    Araki F; Kubo HD; Yang C; Ikegami T; Ishidoya T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Jan; 60(1):67-8. PubMed ID: 15041907
    [TBL] [Abstract][Full Text] [Related]  

  • 77. Study of commercial detector responses in non-equilibrium small photon fields of a 1000MU/min CyberKnife system.
    Huet C; Moignier C; Barraux V; Loiseau C; Sebe-Mercier K; Batalla A; Clairand I
    Phys Med; 2016 Jun; 32(6):818-25. PubMed ID: 27229368
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Characterization of a new unshielded diode for small field dosimetry under flattening filter free beams.
    Reggiori G; Mancosu P; Suchowerska N; Lobefalo F; Stravato A; Tomatis S; Scorsetti M
    Phys Med; 2016 Feb; 32(2):408-13. PubMed ID: 26948386
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Small field correction factors for the IBA Razor.
    Liu PZ; Reggiori G; Lobefalo F; Mancosu P; Tomatis S; McKenzie DR; Suchowerska N
    Phys Med; 2016 Aug; 32(8):1025-9. PubMed ID: 27497923
    [TBL] [Abstract][Full Text] [Related]  

  • 80. The dose response of high-resolution diode-type detectors and the role of their structural components in strong magnetic field.
    Tekin T; Blum I; Delfs B; Schönfeld AB; Kapsch RP; Poppe B; Looe HK
    Med Phys; 2020 Dec; 47(12):6509-6518. PubMed ID: 33074591
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.