These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
111 related articles for article (PubMed ID: 21952982)
1. Brain temperature measurement: A study of in vitro accuracy and stability of smart catheter temperature sensors. Li C; Wu PM; Wu Z; Ahn CH; LeDoux D; Shutter LA; Hartings JA; Narayan RK Biomed Microdevices; 2012 Feb; 14(1):109-18. PubMed ID: 21952982 [TBL] [Abstract][Full Text] [Related]
2. Brain tissue oxygen monitoring: a study of in vitro accuracy and stability of Neurovent-PTO and Licox sensors. Purins K; Enblad P; Sandhagen B; Lewén A Acta Neurochir (Wien); 2010 Apr; 152(4):681-8. PubMed ID: 19826757 [TBL] [Abstract][Full Text] [Related]
3. Accuracy and stability of temperature probes for intracranial application. Alessandri B; Hoelper BM; Behr R; Kempski O J Neurosci Methods; 2004 Oct; 139(2):161-5. PubMed ID: 15488228 [TBL] [Abstract][Full Text] [Related]
4. Micromachined lab-on-a-tube sensors for simultaneous brain temperature and cerebral blood flow measurements. Li C; Wu PM; Hartings JA; Wu Z; Cheyuo C; Wang P; LeDoux D; Shutter LA; Ramaswamy BR; Ahn CH; Narayan RK Biomed Microdevices; 2012 Aug; 14(4):759-68. PubMed ID: 22552801 [TBL] [Abstract][Full Text] [Related]
5. The new Licox combined brain tissue oxygen and brain temperature monitor: assessment of in vitro accuracy and clinical experience in severe traumatic brain injury. Stewart C; Haitsma I; Zador Z; Hemphill JC; Morabito D; Manley G; Rosenthal G Neurosurgery; 2008 Dec; 63(6):1159-64; discussion 1164-5. PubMed ID: 19057329 [TBL] [Abstract][Full Text] [Related]
6. Temperature measurement: comparison of non-invasive methods used in adult critical care. Farnell S; Maxwell L; Tan S; Rhodes A; Philips B J Clin Nurs; 2005 May; 14(5):632-9. PubMed ID: 15840078 [TBL] [Abstract][Full Text] [Related]
7. Clinical evaluation of a new multiparameter neuromonitoring device: measurement of brain tissue oxygen, brain temperature, and intracranial pressure. Huschak G; Hoell T; Hohaus C; Kern C; Minkus Y; Meisel HJ J Neurosurg Anesthesiol; 2009 Apr; 21(2):155-60. PubMed ID: 19295395 [TBL] [Abstract][Full Text] [Related]
8. Characterization of measurement artefacts in fluoroptic temperature sensors: implications for laser thermal therapy at 810 nm. Davidson SR; Vitkin IA; Sherar MD; Whelan WM Lasers Surg Med; 2005 Apr; 36(4):297-306. PubMed ID: 15786482 [TBL] [Abstract][Full Text] [Related]
9. Temporal artery versus bladder thermometry during perioperative and intensive care unit monitoring. Kimberger O; Cohen D; Illievich U; Lenhardt R Anesth Analg; 2007 Oct; 105(4):1042-7, table of contents. PubMed ID: 17898385 [TBL] [Abstract][Full Text] [Related]
10. Measurement of body temperature in adult patients: comparative study of accuracy, reliability and validity of different devices. Rubia-Rubia J; Arias A; Sierra A; Aguirre-Jaime A Int J Nurs Stud; 2011 Jul; 48(7):872-80. PubMed ID: 21145551 [TBL] [Abstract][Full Text] [Related]
11. Toward real-time continuous brain glucose and oxygen monitoring with a smart catheter. Li C; Ahn CH; Shutter LA; Narayan RK Biosens Bioelectron; 2009 Sep; 25(1):173-8. PubMed ID: 19625179 [TBL] [Abstract][Full Text] [Related]
12. Comparison of three methods of temperature measurement in hypothermic, euthermic, and hyperthermic dogs. Greer RJ; Cohn LA; Dodam JR; Wagner-Mann CC; Mann FA J Am Vet Med Assoc; 2007 Jun; 230(12):1841-8. PubMed ID: 17571987 [TBL] [Abstract][Full Text] [Related]
13. Comparing mercury-in-glass, tympanic and disposable thermometers in measuring body temperature in healthy young people. Khorshid L; Eşer I; Zaybak A; Yapucu U J Clin Nurs; 2005 Apr; 14(4):496-500. PubMed ID: 15807757 [TBL] [Abstract][Full Text] [Related]
14. Esophageal luminal temperature measurement underestimates esophageal tissue temperature during radiofrequency ablation within the canine left atrium: comparison between 8 mm tip and open irrigation catheters. Cummings JE; Barrett CD; Litwak KN; DI Biase L; Chowdhury P; Oh S; Ching CK; Saliba WI; Schweikert RA; Burkhardt JD; DE Marco S; Armaganijan L; Natale A J Cardiovasc Electrophysiol; 2008 Jun; 19(6):641-4. PubMed ID: 18373604 [TBL] [Abstract][Full Text] [Related]
15. Temperature measurement in critically ill adults: a comparison of tympanic and oral methods. Giuliano KK; Giuliano AJ; Scott SS; MacLachlan E; Pysznik E; Elliot S; Woytowicz D Am J Crit Care; 2000 Jul; 9(4):254-61. PubMed ID: 10888148 [TBL] [Abstract][Full Text] [Related]
16. Reliability of an infrared forehead skin thermometer for core temperature measurements. Kistemaker JA; Den Hartog EA; Daanen HA J Med Eng Technol; 2006; 30(4):252-61. PubMed ID: 16864237 [TBL] [Abstract][Full Text] [Related]
17. [Body temperature measurement. A comparison of rectal measurement using a mercury thermometer with oral axillary measurement using a new electronic thermometer]. Fretheim R; Mosvold J Tidsskr Nor Laegeforen; 1990 Jan; 110(3):369-71. PubMed ID: 2309182 [TBL] [Abstract][Full Text] [Related]
18. Reliability issues in human brain temperature measurement. Childs C; Machin G Crit Care; 2009; 13(4):R106. PubMed ID: 19573241 [TBL] [Abstract][Full Text] [Related]
19. Brain oxygen monitoring: in-vitro accuracy, long-term drift and response-time of Licox- and Neurotrend sensors. Hoelper BM; Alessandri B; Heimann A; Behr R; Kempski O Acta Neurochir (Wien); 2005 Jul; 147(7):767-74; discussion 774. PubMed ID: 15889319 [TBL] [Abstract][Full Text] [Related]
20. Development of a new method for the noninvasive measurement of deep body temperature without a heater. Kitamura K; Zhu X; Chen W; Nemoto T Med Eng Phys; 2010 Jan; 32(1):1-6. PubMed ID: 19906554 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]