800 related articles for article (PubMed ID: 21956055)
21. Are MRI-based, patient matched cutting jigs as accurate as the tibial guides?
Conteduca F; Iorio R; Mazza D; Caperna L; Bolle G; Argento G; Ferretti A
Int Orthop; 2012 Aug; 36(8):1589-93. PubMed ID: 22426932
[TBL] [Abstract][Full Text] [Related]
22. [Evaluation and analysis of the tibial coronal alignment after total knee replacement with the extramedullary tibial cutting guided by the tibial tubercle and anterior tibial tendon in Chinese patients].
Zhao MW; Tian H; Zeng L; Li BG; Zhang FL; Li LY
Beijing Da Xue Xue Bao Yi Xue Ban; 2016 Apr; 48(2):351-5. PubMed ID: 27080295
[TBL] [Abstract][Full Text] [Related]
23. Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation.
Schotanus MGM; Thijs E; Boonen B; Kerens B; Jong B; Kort NP
Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1656-1661. PubMed ID: 28785788
[TBL] [Abstract][Full Text] [Related]
24. Comparison of robot-assisted and conventional total knee arthroplasty: a controlled cadaver study using multiparameter quantitative three-dimensional CT assessment of alignment.
Moon YW; Ha CW; Do KH; Kim CY; Han JH; Na SE; Lee CH; Kim JG; Park YS
Comput Aided Surg; 2012; 17(2):86-95. PubMed ID: 22348661
[TBL] [Abstract][Full Text] [Related]
25. Comparison of extramedullary versus intramedullary referencing for tibial component alignment in total ankle arthroplasty.
Adams SB; Demetracopoulos CA; Viens NA; DeOrio JK; Easley ME; Queen RM; Nunley JA
Foot Ankle Int; 2013 Dec; 34(12):1624-8. PubMed ID: 24043353
[TBL] [Abstract][Full Text] [Related]
26. Improving tibial component coronal alignment during total knee arthroplasty with use of a tibial planing device.
Patil S; D'Lima DD; Fait JM; Colwell CW
J Bone Joint Surg Am; 2007 Feb; 89(2):381-7. PubMed ID: 17272454
[TBL] [Abstract][Full Text] [Related]
27. Conventional or navigated total knee arthroplasty affects sagittal component alignment.
Sugama R; Minoda Y; Kobayashi A; Iwaki H; Ikebuchi M; Takaoka K; Nakamura H
Knee Surg Sports Traumatol Arthrosc; 2012 Dec; 20(12):2454-9. PubMed ID: 22261992
[TBL] [Abstract][Full Text] [Related]
28. Imageless navigation system does not improve component rotational alignment in total knee arthroplasty.
Cheng T; Zhang G; Zhang X
J Surg Res; 2011 Dec; 171(2):590-600. PubMed ID: 21176919
[TBL] [Abstract][Full Text] [Related]
29. Accelerometer-based computer navigation for performing the distal femoral resection in total knee arthroplasty.
Nam D; Nawabi DH; Cross MB; Heyse TJ; Mayman DJ
J Arthroplasty; 2012 Oct; 27(9):1717-22. PubMed ID: 22440228
[TBL] [Abstract][Full Text] [Related]
30. Radiological outcomes of pinless navigation in total knee arthroplasty: a randomized controlled trial.
Chen JY; Chin PL; Li Z; Yew AK; Tay DK; Chia SL; Lo NN; Yeo SJ
Knee Surg Sports Traumatol Arthrosc; 2015 Dec; 23(12):3556-62. PubMed ID: 25119055
[TBL] [Abstract][Full Text] [Related]
31. Differences between extramedullary, intramedullary, and computer-aided surgery tibial alignment techniques for total knee arthroplasty.
Mihalko WM; Krackow KA
J Knee Surg; 2006 Jan; 19(1):33-6. PubMed ID: 16468492
[TBL] [Abstract][Full Text] [Related]
32. Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty.
Rosenberger RE; Hoser C; Quirbach S; Attal R; Hennerbichler A; Fink C
Knee Surg Sports Traumatol Arthrosc; 2008 Mar; 16(3):249-57. PubMed ID: 18157493
[TBL] [Abstract][Full Text] [Related]
33. Alignments and clinical results in conventional and navigated total knee arthroplasty.
Ensini A; Catani F; Leardini A; Romagnoli M; Giannini S
Clin Orthop Relat Res; 2007 Apr; 457():156-62. PubMed ID: 17195810
[TBL] [Abstract][Full Text] [Related]
34. Surgical Navigation Improves the Precision and Accuracy of Tibial Component Alignment in Canine Total Knee Replacement.
Peters KM; Hutter E; Siston RA; Bertran J; Allen MJ
Vet Surg; 2016 Jan; 45(1):52-9. PubMed ID: 26731596
[TBL] [Abstract][Full Text] [Related]
35. Accuracy of A Handheld Accelerometer-Based Navigation System for Femoral and Tibial Resection in Total Knee Arthroplasty.
Huang EH; Copp SN; Bugbee WD
J Arthroplasty; 2015 Nov; 30(11):1906-10. PubMed ID: 26165954
[TBL] [Abstract][Full Text] [Related]
36. Navigated total knee arthroplasty: is it error-free?
Chua KH; Chen Y; Lingaraj K
Knee Surg Sports Traumatol Arthrosc; 2014 Mar; 22(3):643-9. PubMed ID: 24061715
[TBL] [Abstract][Full Text] [Related]
37. Comparison of radiographic alignment of imageless computer-assisted surgery vs conventional instrumentation in primary total knee arthroplasty.
Barrett WP; Mason JB; Moskal JT; Dalury DF; Oliashirazi A; Fisher DA
J Arthroplasty; 2011 Dec; 26(8):1273-1284.e1. PubMed ID: 21723703
[TBL] [Abstract][Full Text] [Related]
38. Current Role of Computer Navigation in Total Knee Arthroplasty.
Jones CW; Jerabek SA
J Arthroplasty; 2018 Jul; 33(7):1989-1993. PubMed ID: 29506932
[TBL] [Abstract][Full Text] [Related]
39. Twice cutting method reduces tibial cutting error in unicompartmental knee arthroplasty.
Inui H; Taketomi S; Yamagami R; Sanada T; Tanaka S
Knee; 2016 Jan; 23(1):173-6. PubMed ID: 25982299
[TBL] [Abstract][Full Text] [Related]
40. The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty.
Han HS; Kang SB; Jo CH; Kim SH; Lee JH
Knee Surg Sports Traumatol Arthrosc; 2010 Oct; 18(10):1334-8. PubMed ID: 20454779
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]