  • 21. Effect of different repair techniques on the accuracy of repositioning the fractured denture base.
    Goiato MC; Pesqueira AA; Vedovatto E; dos Santos DM; Gennari Filho H
    Gerodontology; 2009 Sep; 26(3):237-41. PubMed ID: 19702821
    [TBL] [Abstract][Full Text] [Related]  

  • 22. An investigation on the influence of tin foil substitute contamination on bond strength between resin denture teeth and the denture base: an in vitro study.
    Bhaskaran S; Hallikerimath RB
    Indian J Dent Res; 2012; 23(4):556. PubMed ID: 23257500
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of the dimensional accuracy of injection-molded denture base materials to that of conventional pressure-pack acrylic resin.
    Parvizi A; Lindquist T; Schneider R; Williamson D; Boyer D; Dawson DV
    J Prosthodont; 2004 Jun; 13(2):83-9. PubMed ID: 15210003
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Efficacy of conventional and experimental techniques for denture repair.
    Rached RN; Powers JM; Del Bel Cury AA
    J Oral Rehabil; 2004 Nov; 31(11):1130-8. PubMed ID: 15525393
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Laboratory fabrication of gold occlusal surfaces for removable and implant-supported prostheses.
    Lloyd PM
    J Prosthodont; 2003 Mar; 12(1):8-12. PubMed ID: 12677605
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Pressure transmission and distribution under impact load using artificial denture teeth made of different materials.
    Phunthikaphadr T; Takahashi H; Arksornnukit M
    J Prosthet Dent; 2009 Nov; 102(5):319-27. PubMed ID: 19853174
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Wear of two denture teeth materials in vivo-2-year results.
    Heintze SD; Zellweger G; Sbicego S; Rousson V; Muñoz-Viveros C; Stober T
    Dent Mater; 2013 Sep; 29(9):e191-204. PubMed ID: 23746749
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effects of the position of artificial teeth and load levels on stress in the complete maxillary denture.
    Prombonas A; Vlissidis D
    J Prosthet Dent; 2002 Oct; 88(4):415-22. PubMed ID: 12447219
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The effect of relining on the accuracy and stability of maxillary complete dentures--an in vitro and in vivo study.
    Barco MT; Moore BK; Swartz ML; Boone ME; Dykema RW; Phillips RW
    J Prosthet Dent; 1979 Jul; 42(1):17-22. PubMed ID: 379306
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of Cast Modification on Denture Base Adaptation Following Maxillary Complete Denture Processing.
    Sayed ME; Porwal A; Ehrenberg D; Weiner S
    J Prosthodont; 2019 Jan; 28(1):e6-e12. PubMed ID: 28102940
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Using acrylic resin tooth veneers in patients with an abnormal jaw relationship: a case report.
    Yang TC; Lan YH; Wang TM; Tu CY; Lin LD
    Int J Prosthodont; 2014; 27(6):570-2. PubMed ID: 25390873
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of different curing temperatures on the distortion at the posterior peripheral seal: an in vitro study.
    Pasam N; Hallikerimath RB; Arora A; Gilra S
    Indian J Dent Res; 2012; 23(3):301-4. PubMed ID: 23059563
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Comparison of the linear dimensional accuracy of denture bases cured the by conventional method and by the new press technique.
    Abby A; Kumar R; Shibu J; Chakravarthy R
    Indian J Dent Res; 2011; 22(2):200-4. PubMed ID: 21891885
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Shear bond strength of denture teeth to two chemically different denture base resins after various surface treatments.
    Akin H; Tugut F; Guney U; Akar T
    J Prosthodont; 2014 Feb; 23(2):152-6. PubMed ID: 23889780
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing.
    Hwang HJ; Lee SJ; Park EJ; Yoon HI
    J Prosthet Dent; 2019 Jan; 121(1):110-117. PubMed ID: 30006217
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparative bond strengths of plastic teeth to microwave-curing, heat-curing and 4-META containing denture base resins.
    Yamauchi M; Iwahori M; Sakai M; Koda T; Kawano J; Maeno T
    Gifu Shika Gakkai Zasshi; 1989 Dec; 16(2):542-50. PubMed ID: 2489448
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of monomer treatment and polymerisation methods on the bond strength of resin teeth to denture base material.
    Barbosa DB; Monteiro DR; Barão VA; Pero AC; Compagnoni MA
    Gerodontology; 2009 Sep; 26(3):225-31. PubMed ID: 19702820
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Reinforcement of a mandibular complete denture with internal metal framework.
    Balch JH; Smith PD; Marin MA; Cagna DR
    J Prosthet Dent; 2013 Mar; 109(3):202-5. PubMed ID: 23522371
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Three-dimensional processing deformation of three denture base materials.
    Artopoulos A; Juszczyk AS; Rodriguez JM; Clark RK; Radford DR
    J Prosthet Dent; 2013 Dec; 110(6):481-7. PubMed ID: 24189112
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques.
    Goodacre BJ; Goodacre CJ; Baba NZ; Kattadiyil MT
    J Prosthet Dent; 2016 Aug; 116(2):249-56. PubMed ID: 27112416
    [TBL] [Abstract][Full Text] [Related]  