These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

734 related articles for article (PubMed ID: 21963124)

  • 1. Vacuum-assisted socket suspension compared with pin suspension for lower extremity amputees: effect on fit, activity, and limb volume.
    Klute GK; Berge JS; Biggs W; Pongnumkul S; Popovic Z; Curless B
    Arch Phys Med Rehabil; 2011 Oct; 92(10):1570-5. PubMed ID: 21963124
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Residual limb wounds or ulcers heal in transtibial amputees using an active suction socket system. A randomized controlled study.
    Traballesi M; Delussu AS; Fusco A; Iosa M; Averna T; Pellegrini R; Brunelli S
    Eur J Phys Rehabil Med; 2012 Dec; 48(4):613-23. PubMed ID: 22641248
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transtibial prosthetic socket pistoning: static evaluation of Seal-In(®) X5 and Dermo(®) Liner using motion analysis system.
    Gholizadeh H; Osman NA; Kamyab M; Eshraghi A; Abas WA; Azam MN
    Clin Biomech (Bristol); 2012 Jan; 27(1):34-9. PubMed ID: 21794965
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison between the suction suspension system and the hypobaric Iceross Seal-In® X5 in transtibial amputees.
    Brunelli S; Delussu AS; Paradisi F; Pellegrini R; Traballesi M
    Prosthet Orthot Int; 2013 Dec; 37(6):436-44. PubMed ID: 23436696
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Transfemoral sockets with vacuum-assisted suspension comparison of hip kinematics, socket position, contact pressure, and preference: ischial containment versus brimless.
    Kahle JT; Highsmith MJ
    J Rehabil Res Dev; 2013; 50(9):1241-52. PubMed ID: 24458964
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Axial bone-socket displacement for persons with a traumatic transtibial amputation: The effect of elevated vacuum suspension at progressive body-weight loads.
    Darter BJ; Sinitski K; Wilken JM
    Prosthet Orthot Int; 2016 Oct; 40(5):552-7. PubMed ID: 26423107
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An experimental study of the interface pressure profile during level walking of a new suspension system for lower limb amputees.
    Eshraghi A; Abu Osman NA; Gholizadeh H; Ali S; Sævarsson SK; Wan Abas WA
    Clin Biomech (Bristol); 2013 Jan; 28(1):55-60. PubMed ID: 23157843
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets.
    Beil TL; Street GM; Covey SJ
    J Rehabil Res Dev; 2002; 39(6):693-700. PubMed ID: 17943671
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantitative and qualitative comparison of a new prosthetic suspension system with two existing suspension systems for lower limb amputees.
    Eshraghi A; Abu Osman NA; Karimi MT; Gholizadeh H; Ali S; Wan Abas WA
    Am J Phys Med Rehabil; 2012 Dec; 91(12):1028-38. PubMed ID: 23168378
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The authors respond: vacuum-assisted socket suspension systems for lower extremity amputees: effect on fit, activity, and limb volume.
    Klute GK; Berge JS; Biggs W; Pongnumkul S; Popovic Z; Curless B
    Arch Phys Med Rehabil; 2012 May; 93(5):922-3. PubMed ID: 22541317
    [No Abstract]   [Full Text] [Related]  

  • 11. A comparison of trans-tibial amputee suction and vacuum socket conditions.
    Board WJ; Street GM; Caspers C
    Prosthet Orthot Int; 2001 Dec; 25(3):202-9. PubMed ID: 11860094
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Elevated vacuum suspension preserves residual-limb skin health in people with lower-limb amputation: Randomized clinical trial.
    Rink C; Wernke MM; Powell HM; Gynawali S; Schroeder RM; Kim JY; Denune JA; Gordillo GM; Colvin JM; Sen CK
    J Rehabil Res Dev; 2016; 53(6):1121-1132. PubMed ID: 28355039
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The benefits of using a vacuum-assisted socket system to improve balance and gait in elderly transtibial amputees.
    Samitier CB; Guirao L; Costea M; Camós JM; Pleguezuelos E
    Prosthet Orthot Int; 2016 Feb; 40(1):83-8. PubMed ID: 25261489
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effectiveness of elevated vacuum and suction prosthetic suspension systems in managing daily residual limb fluid volume change in people with transtibial amputation.
    Youngblood RT; Brzostowski JT; Hafner BJ; Czerniecki JM; Allyn KJ; Foster RL; Sanders JE
    Prosthet Orthot Int; 2020 Jun; 44(3):155-163. PubMed ID: 32186238
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The evidence-base for elevated vacuum in lower limb prosthetics: Literature review and professional feedback.
    Gholizadeh H; Lemaire ED; Eshraghi A
    Clin Biomech (Bristol); 2016 Aug; 37():108-116. PubMed ID: 27423025
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of activity intensity, time, and intermittent doffing on daily limb fluid volume change in people with transtibial amputation.
    Youngblood RT; Hafner BJ; Allyn KJ; Cagle JC; Hinrichs P; Redd C; Vamos AC; Ciol MA; Bean N; Sanders JE
    Prosthet Orthot Int; 2019 Feb; 43(1):28-38. PubMed ID: 30010494
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Prosthesis management of residual-limb perspiration with subatmospheric vacuum pressure.
    Klute GK; Bates KJ; Berge JS; Biggs W; King C
    J Rehabil Res Dev; 2016; 53(6):721-728. PubMed ID: 27997669
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Gait biomechanics of individuals with transtibial amputation: effect of suspension system.
    Eshraghi A; Abu Osman NA; Karimi M; Gholizadeh H; Soodmand E; Wan Abas WA
    PLoS One; 2014; 9(5):e96988. PubMed ID: 24865351
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dynamic interface pressure distributions of two transtibial prosthetic socket concepts.
    Dumbleton T; Buis AW; McFadyen A; McHugh BF; McKay G; Murray KD; Sexton S
    J Rehabil Res Dev; 2009; 46(3):405-15. PubMed ID: 19675992
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A new approach for the pistoning measurement in transtibial prosthesis.
    Gholizadeh H; Abu Osman NA; Lúvíksdóttir Á; Eshraghi A; Kamyab M; Wan Abas WA
    Prosthet Orthot Int; 2011 Dec; 35(4):360-4. PubMed ID: 21975850
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 37.