179 related articles for article (PubMed ID: 21970982)
1. Use of minimal extracorporeal circulation circuit for left ventricular assist device implantation.
Anastasiadis K; Antonitsis P; Argiriadou H; Khayat A; Papakonstantinou C; Westaby S
ASAIO J; 2011; 57(6):547-9. PubMed ID: 21970982
[TBL] [Abstract][Full Text] [Related]
2. Minimal extracorporeal circulation circuit standby for "off-pump" left ventricular assist device implantation.
Anastasiadis K; Westaby S; Antonitsis P; Argiriadou H; Karapanagiotidis G; Pigott D; Papakonstantinou C
Artif Organs; 2010 Dec; 34(12):1156-8. PubMed ID: 20545669
[TBL] [Abstract][Full Text] [Related]
3. Tentacles: a novel device for exposing the heart for the insertion of left apical assist device cannulae.
Schmauss D; Kaczmarek I; Beiras-Fernandez A; Bigdeli AK; Eifert S; Christ F; Reichart B; Vicol C
Heart Surg Forum; 2009 Apr; 12(2):E116-8. PubMed ID: 19383586
[TBL] [Abstract][Full Text] [Related]
4. Use of minimized extracorporeal circulation system in noncoronary and valve cardiac surgical procedures-a case series.
Anastasiadis K; Chalvatzoulis O; Antonitsis P; Deliopoulos A; Argiriadou H; Karapanagiotidis G; Kambouroglou D; Papakonstantinou C
Artif Organs; 2011 Oct; 35(10):960-3. PubMed ID: 21501191
[TBL] [Abstract][Full Text] [Related]
5. Implantation of the Jarvik 2000® left ventricular assist device using the miniaturized extracorporeal circulation system - a case report.
Formica F; Bamodu OA; Mariani S; Caruso R; Sangalli F; Paolini G
Perfusion; 2016 Sep; 31(6):518-20. PubMed ID: 26791274
[TBL] [Abstract][Full Text] [Related]
6. Ventricular assist device implantation in patients on percutaneous extracorporeal life support without switching to conventional cardiopulmonary bypass system.
Haneya A; Philipp A; Puehler T; Ried M; Hilker M; Zink W; Hirt SW; Schmid C
Eur J Cardiothorac Surg; 2012 Jun; 41(6):1366-70. PubMed ID: 22228845
[TBL] [Abstract][Full Text] [Related]
7. Off-pump implant of the Jarvik 2000 ventricular assist device through median sternotomy.
Anyanwu AC; Fischer GW; Plotkina I; Pinney S; Adams DH
Ann Thorac Surg; 2007 Oct; 84(4):1405-7. PubMed ID: 17889020
[TBL] [Abstract][Full Text] [Related]
8. Less invasive surgical and perfusion technique for implantation of the Jarvik 2000 left ventricular assist device.
Gerosa G; Gallo M; Tarzia V; Di Gregorio G; Zanella F; Bottio T
Ann Thorac Surg; 2013 Aug; 96(2):712-4. PubMed ID: 23910126
[TBL] [Abstract][Full Text] [Related]
9. Successful Implantation of a Left Ventricular Assist Device After Treatment With the Paracor HeartNet.
Schweiger M; Stepanenko A; Potapov E; Drews T; Hetzer R; Krabatsch T
ASAIO J; 2010; 56(5):457-9. PubMed ID: 20595889
[TBL] [Abstract][Full Text] [Related]
10. Off-pump implantation of the HeartWare HVAD left ventricular assist device through minimally invasive incisions.
Cheung A; Lamarche Y; Kaan A; Munt B; Doyle A; Bashir J; Janz P
Ann Thorac Surg; 2011 Apr; 91(4):1294-6. PubMed ID: 21440172
[TBL] [Abstract][Full Text] [Related]
11. Viennese approach to minimize the invasiveness of ventricular assist device implantation†.
Haberl T; Riebandt J; Mahr S; Laufer G; Rajek A; Schima H; Zimpfer D
Eur J Cardiothorac Surg; 2014 Dec; 46(6):991-6; discussion 996. PubMed ID: 24623170
[TBL] [Abstract][Full Text] [Related]
12. Successful use of a percutaneous miniaturized extracorporeal life support system as a bridge and assistance to left ventricular assist device implantation in a patient with severe refractory cardiogenic shock.
Haneya A; Philipp A; Puehler T; Camboni D; Hilker M; Hirt SW; Schmid C
Perfusion; 2012 Jan; 27(1):18-20. PubMed ID: 21859786
[TBL] [Abstract][Full Text] [Related]
13. Reinforcement of left ventricular assist device outflow grafts to prevent kinking.
Cohn WE; Gregoric ID; Frazier OH
Ann Thorac Surg; 2007 Jul; 84(1):301-2. PubMed ID: 17588447
[TBL] [Abstract][Full Text] [Related]
14. Thoratec implantable ventricular assist device: the Papworth experience.
Berman M; Parameshwar J; Jenkins DP; Dhital K; Lewis C; Dempster K; Lincoln P; Sudarshan C; Large SR; Dunning J; Tsui SS
J Thorac Cardiovasc Surg; 2010 Feb; 139(2):466-73. PubMed ID: 19833355
[TBL] [Abstract][Full Text] [Related]
15. Use of the percutaneous left ventricular assist device in patients with severe refractory cardiogenic shock as a bridge to long-term left ventricular assist device implantation.
Idelchik GM; Simpson L; Civitello AB; Loyalka P; Gregoric ID; Delgado R; Kar B
J Heart Lung Transplant; 2008 Jan; 27(1):106-11. PubMed ID: 18187095
[TBL] [Abstract][Full Text] [Related]
16. Successful treatment of a Novacor LVAD malfunction without repeat sternotomy.
Hammel D; Tjan DT; Scheld HH; Schmid C; Loick M; Deng MC
Thorac Cardiovasc Surg; 1998 Jun; 46(3):154-6. PubMed ID: 9714492
[TBL] [Abstract][Full Text] [Related]
17. Extracorporeal membrane oxygenation as perioperative right ventricular support in patients with biventricular failure undergoing left ventricular assist device implantation.
Scherer M; Sirat AS; Moritz A; Martens S
Eur J Cardiothorac Surg; 2011 Jun; 39(6):939-44; discussion 944. PubMed ID: 21071240
[TBL] [Abstract][Full Text] [Related]
18. Biventricular circulatory support with two miniaturized implantable assist devices.
Krabatsch T; Potapov E; Stepanenko A; Schweiger M; Kukucka M; Huebler M; Hennig E; Hetzer R
Circulation; 2011 Sep; 124(11 Suppl):S179-86. PubMed ID: 21911810
[TBL] [Abstract][Full Text] [Related]
19. Clinical application of BVS5000 left ventricular assist device in heart failure patients.
Luo XJ; Hu SS; Sun HS; Xu JP; Liu P; Zheng Z; Ma WG; Zhang Y
Chin Med J (Engl); 2008 May; 121(10):877-80. PubMed ID: 18706199
[TBL] [Abstract][Full Text] [Related]
20. Ventricular assist device outflow-graft site: effect on myocardial blood flow.
Tuzun E; Narin C; Gregoric ID; Cohn WE; Frazier OH
J Surg Res; 2011 Nov; 171(1):71-5. PubMed ID: 20605602
[TBL] [Abstract][Full Text] [Related]