These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 21974567)

  • 1. Optical scanning system for light-absorption measurement of deep biological tissue.
    Funane T; Atsumori H; Kiguchi M; Tanikawa Y; Okada E
    Rev Sci Instrum; 2011 Sep; 82(9):093101. PubMed ID: 21974567
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantitative evaluation of deep and shallow tissue layers' contribution to fNIRS signal using multi-distance optodes and independent component analysis.
    Funane T; Atsumori H; Katura T; Obata AN; Sato H; Tanikawa Y; Okada E; Kiguchi M
    Neuroimage; 2014 Jan; 85 Pt 1():150-65. PubMed ID: 23439443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optical absorption characteristics in the assessment of powder phosphor-based x-ray detectors: from nano- to micro-scale.
    Liaparinos PF
    Phys Med Biol; 2015 Nov; 60(22):8885-99. PubMed ID: 26553576
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optical absorption and scattering properties of bulk porcine muscle phantoms from interstitial radiance measurements in 650-900 nm range.
    Grabtchak S; Montgomery LG; Whelan WM
    Phys Med Biol; 2014 May; 59(10):2431-44. PubMed ID: 24743553
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Optical parameters of embedded abnormalities in tissues as determined by Monte Carlo simulation.
    Jeeva JB; Singh M
    Electromagn Biol Med; 2012 Sep; 31(3):204-12. PubMed ID: 22897401
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Light wavelength effects in submicrometer phosphor materials using Mie scattering and Monte Carlo simulation.
    Liaparinos PF
    Med Phys; 2013 Oct; 40(10):101911. PubMed ID: 24089913
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Implementation of a phase array diffuse optical tomographic imager.
    Rajan K; Vijayakumar V; Biswas SK; Vasu RM
    Rev Sci Instrum; 2008 Aug; 79(8):084301. PubMed ID: 19044366
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Localization and characterization of tissue changes by laser backscattering imaging and Monte Carlo simulation.
    Pandian PS; Singh M
    Indian J Exp Biol; 2010 Oct; 48(10):993-1001. PubMed ID: 21299042
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noncontact backscatter-mode near-infrared time-resolved imaging system: Preliminary study for functional brain mapping.
    Sase I; Takatsuki A; Seki J; Yanagida T; Seiyama A
    J Biomed Opt; 2006; 11(5):054006. PubMed ID: 17092155
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Numerical study of reflectance imaging using a parallel Monte Carlo method.
    Chen C; Lu JQ; Li K; Zhao S; Brock RS; Hu XH
    Med Phys; 2007 Jul; 34(7):2939-48. PubMed ID: 17822002
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optical Characterization of Tissue Phantoms Using a Silicon Integrated fdNIRS System on Chip.
    Sthalekar CC; Miao Y; Koomson VJ
    IEEE Trans Biomed Circuits Syst; 2017 Apr; 11(2):279-286. PubMed ID: 28113987
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quantification of fluorophore concentration in tissue-simulating media by fluorescence measurements with a single optical fiber.
    Diamond KR; Patterson MS; Farrell TJ
    Appl Opt; 2003 May; 42(13):2436-42. PubMed ID: 12737480
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.
    DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF
    Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Near-infrared optical imaging of tissue phantoms with measurement in the change of optical path lengths.
    Sevick EM; Burch CL; Chance B
    Adv Exp Med Biol; 1994; 345():815-23. PubMed ID: 8079791
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bio-optical model describing the distribution of irradiance at the sea surface resulting from a point source embedded in the ocean.
    Gordon HR
    Appl Opt; 1987 Oct; 26(19):4133-48. PubMed ID: 20490199
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Spatially resolved absolute diffuse reflectance measurements for noninvasive determination of the optical scattering and absorption coefficients of biological tissue.
    Kienle A; Lilge L; Patterson MS; Hibst R; Steiner R; Wilson BC
    Appl Opt; 1996 May; 35(13):2304-14. PubMed ID: 21085367
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Differential pathlength factor estimation for brain-like tissue from a single-layer Monte Carlo model.
    Chatterjee S; Phillips JP; Kyriacou PA
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():3279-82. PubMed ID: 26736992
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dynamic phantom with two stage-driven absorbers for mimicking hemoglobin changes in superficial and deep tissues.
    Funane T; Atsumori H; Kiguchi M; Tanikawa Y; Okada E
    J Biomed Opt; 2012 Apr; 17(4):047001. PubMed ID: 22559692
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Solid hemoglobin-polymer phantoms for evaluation of biophotonic systems.
    Jang H; Pfefer TJ; Chen Y
    Opt Lett; 2015 Sep; 40(18):4321-4. PubMed ID: 26371926
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Depth profile of diffuse reflectance near-infrared spectroscopy for measurement of water content in skin.
    Arimoto H; Egawa M; Yamada Y
    Skin Res Technol; 2005 Feb; 11(1):27-35. PubMed ID: 15691256
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.