These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

490 related articles for article (PubMed ID: 21981983)

  • 1. Evaluation of an alternative HIV diagnostic algorithm using specimens from seroconversion panels and persons with established HIV infections.
    Masciotra S; McDougal JS; Feldman J; Sprinkle P; Wesolowski L; Owen SM
    J Clin Virol; 2011 Dec; 52 Suppl 1():S17-22. PubMed ID: 21981983
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Performance of an alternative laboratory-based algorithm for diagnosis of HIV infection utilizing a third generation immunoassay, a rapid HIV-1/HIV-2 differentiation test and a DNA or RNA-based nucleic acid amplification test in persons with established HIV-1 infection and blood donors.
    Wesolowski LG; Delaney KP; Hart C; Dawson C; Owen SM; Candal D; Meyer WA; Ethridge SF; Branson BM
    J Clin Virol; 2011 Dec; 52 Suppl 1():S45-9. PubMed ID: 21995934
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance of an alternative laboratory-based algorithm for HIV diagnosis in a high-risk population.
    Delaney KP; Heffelfinger JD; Wesolowski LG; Owen SM; Meyer WA; Kennedy S; Uniyal A; Kerndt PR; Branson BM
    J Clin Virol; 2011 Dec; 52 Suppl 1():S5-10. PubMed ID: 22019251
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Multispot EIA with Western blot for confirmatory serodiagnosis of HIV.
    Torian LV; Forgione LA; Punsalang AE; Pirillo RE; Oleszko WR
    J Clin Virol; 2011 Dec; 52 Suppl 1():S41-4. PubMed ID: 21995935
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the performance of the Abbott ARCHITECT HIV Ag/Ab Combo Assay.
    Chavez P; Wesolowski L; Patel P; Delaney K; Owen SM
    J Clin Virol; 2011 Dec; 52 Suppl 1():S51-5. PubMed ID: 21983253
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of an alternative supplemental testing strategy for HIV diagnosis by retrospective analysis of clinical HIV testing data.
    Styer LM; Sullivan TJ; Parker MM
    J Clin Virol; 2011 Dec; 52 Suppl 1():S35-40. PubMed ID: 22018662
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative evaluation of Aptima HIV-1 Qualitative RNA assay performance using plasma and serum specimens from persons with established HIV-1 infection.
    Ethridge SF; Wesolowski LG; Nasrullah M; Kennedy MS; Delaney KP; Candal D; Owen SM
    J Clin Virol; 2011 Dec; 52 Suppl 1():S63-6. PubMed ID: 21995932
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of alternative interpretive criteria for the HIV-1 Western blot and results of the Multispot HIV-1/HIV-2 Rapid Test for classifying HIV-1 and HIV-2 infections.
    Nasrullah M; Ethridge SF; Delaney KP; Wesolowski LG; Granade TC; Schwendemann J; Boromisa RD; Heffelfinger JD; Owen SM; Branson BM
    J Clin Virol; 2011 Dec; 52 Suppl 1():S23-7. PubMed ID: 21993309
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of supplemental testing with the Multispot HIV-1/HIV-2 Rapid Test and APTIMA HIV-1 RNA Qualitative Assay to resolve specimens with indeterminate or negative HIV-1 Western blots.
    Linley L; Ethridge SF; Oraka E; Owen SM; Wesolowski LG; Wroblewski K; Landgraf KM; Parker MM; Brinson M; Branson BM
    J Clin Virol; 2013 Dec; 58 Suppl 1():e108-12. PubMed ID: 24342469
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Performance evaluation of the Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA, a 4th generation HIV assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma.
    Bentsen C; McLaughlin L; Mitchell E; Ferrera C; Liska S; Myers R; Peel S; Swenson P; Gadelle S; Shriver MK
    J Clin Virol; 2011 Dec; 52 Suppl 1():S57-61. PubMed ID: 21995929
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of the new HIV-1/2 diagnostic algorithm in Florida's public health testing population: a review of the first five months of utilization.
    Bennett B; Neumann D; Fordan S; Villaraza R; Crowe S; Gillis L
    J Clin Virol; 2013 Dec; 58 Suppl 1():e29-33. PubMed ID: 24342476
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Costs and outcomes of laboratory diagnostic algorithms for the detection of HIV.
    Hutchinson AB; Ethridge SF; Wesolowski LG; Shrestha RK; Pentella M; Bennett B; Farnham PG; Sullivan T; Patel P; Branson BM
    J Clin Virol; 2013 Dec; 58 Suppl 1():e2-7. PubMed ID: 24342475
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of the CDC proposed laboratory HIV testing algorithm among men who have sex with men (MSM) from five US metropolitan statistical areas using specimens collected in 2011.
    Masciotra S; Smith AJ; Youngpairoj AS; Sprinkle P; Miles I; Sionean C; Paz-Bailey G; Johnson JA; Owen SM
    J Clin Virol; 2013 Dec; 58 Suppl 1(Suppl 1):e8-e12. PubMed ID: 24342483
    [TBL] [Abstract][Full Text] [Related]  

  • 14. HIV single staging algorithm: integration and maximization of resources by reducing time between HIV diagnosis and treatment.
    Bennett B; Hardy B; Fordan S; Haddock-Morilla L; Rowlinson MC; Crowe S
    J Clin Virol; 2013 Dec; 58 Suppl 1():e34-7. PubMed ID: 23993447
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detecting acute human immunodeficiency virus infection using 3 different screening immunoassays and nucleic acid amplification testing for human immunodeficiency virus RNA, 2006-2008.
    Patel P; Mackellar D; Simmons P; Uniyal A; Gallagher K; Bennett B; Sullivan TJ; Kowalski A; Parker MM; LaLota M; Kerndt P; Sullivan PS;
    Arch Intern Med; 2010 Jan; 170(1):66-74. PubMed ID: 20065201
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of turnaround time and total cost of HIV testing before and after implementation of the 2014 CDC/APHL Laboratory Testing Algorithm for diagnosis of HIV infection.
    Chen DJ; Yao JD
    J Clin Virol; 2017 Jun; 91():69-72. PubMed ID: 28461133
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative evaluation of the Bio-Rad Geenius HIV-1/2 Confirmatory Assay and the Bio-Rad Multispot HIV-1/2 Rapid Test as an alternative differentiation assay for CLSI M53 algorithm-I.
    Malloch L; Kadivar K; Putz J; Levett PN; Tang J; Hatchette TF; Kadkhoda K; Ng D; Ho J; Kim J
    J Clin Virol; 2013 Dec; 58 Suppl 1():e85-91. PubMed ID: 24342484
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the Bio-Rad Multispot HIV-1/HIV-2 Rapid Test as an alternative to Western blot for confirmation of HIV infection.
    Cárdenas AM; Baughan E; Hodinka RL
    J Clin Virol; 2013 Dec; 58 Suppl 1():e97-e103. PubMed ID: 24113294
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays.
    Kwon JA; Yoon SY; Lee CK; Lim CS; Lee KN; Sung HJ; Brennan CA; Devare SG
    J Virol Methods; 2006 Apr; 133(1):20-6. PubMed ID: 16313975
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of six commercial enzyme immunoassays and two alternative HIV-testing algorithms for the diagnosis of HIV-1 infection in Kisumu, Western Kenya.
    Zeh C; Oyaro B; Vandenhoudt H; Amornkul P; Kasembeli A; Bondo P; Mwaengo D; Thomas TK; Hart C; Laserson KF; Ondoa P; Nkengasong JN
    J Virol Methods; 2011 Sep; 176(1-2):24-31. PubMed ID: 21635920
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 25.