1278 related articles for article (PubMed ID: 21983370)
1. Effect of the bevel direction of puncture needle on success rate and complications during internal jugular vein catheterization.
Lim T; Ryu HG; Jung CW; Jeon Y; Bahk JH
Crit Care Med; 2012 Feb; 40(2):491-4. PubMed ID: 21983370
[TBL] [Abstract][Full Text] [Related]
2. Comparison of Needle Insertion and Guidewire Placement Techniques During Internal Jugular Vein Catheterization: The Thin-Wall Introducer Needle Technique Versus the Cannula-Over-Needle Technique.
Lee YH; Kim TK; Jung YS; Cho YJ; Yoon S; Seo JH; Jeon Y; Bahk JH; Hong DM
Crit Care Med; 2015 Oct; 43(10):2112-6. PubMed ID: 26121076
[TBL] [Abstract][Full Text] [Related]
3. Put the bevel down and visualize the needle tip when puncturing the internal jugular vein.
Fritsch G; Brunauer A; Dünser MW
Crit Care Med; 2012 Aug; 40(8):2533; author reply 2534. PubMed ID: 22809943
[No Abstract] [Full Text] [Related]
4. Ultrasound-guided external jugular vein cannulation for central venous access by inexperienced trainees.
Mitre CI; Golea A; Acalovschi I; Mocan T; Caea AM; Ruţă C; Mariana M
Eur J Anaesthesiol; 2010 Mar; 27(3):300-3. PubMed ID: 19935072
[TBL] [Abstract][Full Text] [Related]
5. Thumbs up for bevel down.
Gilchrist IC
Crit Care Med; 2012 Feb; 40(2):678-9. PubMed ID: 22249048
[No Abstract] [Full Text] [Related]
6. [Ultrasound-guided puncture of the jugular vein using a posterior approach].
Pérez Reyes JM; Bethencourt Muñoz S; Cabrejas Ibarz MT; Tejero García M; Valdivia Martín J; González Miranda F
Rev Esp Anestesiol Reanim; 2008 Dec; 55(10):616-20. PubMed ID: 19177863
[TBL] [Abstract][Full Text] [Related]
7. Anchoring of the internal jugular vein with a pilot needle to facilitate its puncture with a wide bore needle: a randomised, prospective, clinical study.
Tripathi M; Pandey M
Anaesthesia; 2006 Jan; 61(1):15-9. PubMed ID: 16409336
[TBL] [Abstract][Full Text] [Related]
8. US-guided placement of temporary internal jugular vein catheters: immediate technical success and complications in normal and high-risk patients.
Oguzkurt L; Tercan F; Kara G; Torun D; Kizilkilic O; Yildirim T
Eur J Radiol; 2005 Jul; 55(1):125-9. PubMed ID: 15950110
[TBL] [Abstract][Full Text] [Related]
9. [Application of ultrasonic surface location for internal jugular vein catheterization via central approach].
Zhang YL; Mi WD; Yu DJ; Fu Q; Feng XX
Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2011 Oct; 33(5):479-84. PubMed ID: 22338128
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of an ultrasound-guided technique for central venous access via the internal jugular vein in 493 patients.
Mey U; Glasmacher A; Hahn C; Gorschlüter M; Ziske C; Mergelsberg M; Sauerbruch T; Schmidt-Wolf IG
Support Care Cancer; 2003 Mar; 11(3):148-55. PubMed ID: 12618924
[TBL] [Abstract][Full Text] [Related]
11. Patient Factors But Not the Use of Novel Anticoagulants or Warfarin Are Associated With Internal Jugular Vein Access-Site Hematoma After Right Heart Catheterization.
Dasa O; Shafiq Q; Ruzieh M; Alhazmi L; Al-Dabbas M; Ammari Z; Khouri S; Moukarbel G
J Invasive Cardiol; 2017 Dec; 29(12):401-403. PubMed ID: 29207361
[TBL] [Abstract][Full Text] [Related]
12. Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization.
Brass P; Hellmich M; Kolodziej L; Schick G; Smith AF
Cochrane Database Syst Rev; 2015 Jan; 1(1):CD006962. PubMed ID: 25575244
[TBL] [Abstract][Full Text] [Related]
13. Is long-axis view superior to short-axis view in ultrasound-guided central venous catheterization?
Vogel JA; Haukoos JS; Erickson CL; Liao MM; Theoret J; Sanz GE; Kendall J
Crit Care Med; 2015 Apr; 43(4):832-9. PubMed ID: 25517477
[TBL] [Abstract][Full Text] [Related]
14. Central venous infusion port inserted via high versus low jugular venous approaches: retrospective comparison of outcome and complications.
Park HS; Kim YI; Lee SH; Kim JI; Seo H; Lee SM; Lee Y; Lim MK; Park YS
Eur J Radiol; 2009 Dec; 72(3):494-8. PubMed ID: 19200682
[TBL] [Abstract][Full Text] [Related]
15. Effects of four different positive airway pressures on right internal jugular vein catheterisation.
Zhou Q; Xiao W; An E; Zhou H; Yan M
Eur J Anaesthesiol; 2012 May; 29(5):223-8. PubMed ID: 22228239
[TBL] [Abstract][Full Text] [Related]
16. An unseen danger: frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance.
Blaivas M; Adhikari S
Crit Care Med; 2009 Aug; 37(8):2345-9; quiz 2359. PubMed ID: 19531950
[TBL] [Abstract][Full Text] [Related]
17. [Ultrasonography guided versus anatomically oriented puncture of the internal jugular vein for central venous catheterization].
Böck U; Möllhoff T; Förster R
Ultraschall Med; 1999 Jun; 20(3):98-103. PubMed ID: 10444779
[TBL] [Abstract][Full Text] [Related]
18. Feasibility of the Use of Transesophageal Echocardiography as a Surface Probe for Puncturing and Catheterization of the Internal Jugular Vein: A Randomized Controlled Pilot Study.
Teng Y; Ou M; Yu H
J Cardiothorac Vasc Anesth; 2018 Feb; 32(1):363-369. PubMed ID: 29132805
[TBL] [Abstract][Full Text] [Related]
19. Is a neutral head position as effective as head rotation during landmark-guided internal jugular vein cannulation? Results of a randomized controlled clinical trial.
Apiliogullari B; Kara I; Apiliogullari S; Arun O; Saltali A; Celik JB
J Cardiothorac Vasc Anesth; 2012 Dec; 26(6):985-8. PubMed ID: 22995458
[TBL] [Abstract][Full Text] [Related]
20. A randomized trial of ultrasound image-based skin surface marking versus real-time ultrasound-guided internal jugular vein catheterization in infants.
Hosokawa K; Shime N; Kato Y; Hashimoto S
Anesthesiology; 2007 Nov; 107(5):720-4. PubMed ID: 18073546
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]