127 related articles for article (PubMed ID: 21992363)
1. Extraction of depth-dependent perturbation factors for silicon diodes using a plastic scintillation detector.
Lacroix F; Guillot M; McEwen M; Gingras L; Beaulieu L
Med Phys; 2011 Oct; 38(10):5441-7. PubMed ID: 21992363
[TBL] [Abstract][Full Text] [Related]
2. Extraction of depth-dependent perturbation factors for parallel-plate chambers in electron beams using a plastic scintillation detector.
Lacroix F; Guillot M; McEwen M; Cojocaru C; Gingras L; Beddar AS; Beaulieu L
Med Phys; 2010 Aug; 37(8):4331-42. PubMed ID: 20879593
[TBL] [Abstract][Full Text] [Related]
3. A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: the case of the CyberKnife.
Morin J; Beliveau-Nadeau D; Chung E; Seuntjens J; Theriault D; Archambault L; Beddar S; Beaulieu L
Med Phys; 2013 Jan; 40(1):011719. PubMed ID: 23298089
[TBL] [Abstract][Full Text] [Related]
4. Effective point of measurement for parallel plate and cylindrical ion chambers in megavoltage electron beams.
von Voigts-Rhetz P; Czarnecki D; Zink K
Z Med Phys; 2014 Sep; 24(3):216-23. PubMed ID: 24418322
[TBL] [Abstract][Full Text] [Related]
5. Spectral perturbations from silicon diode detector encapsulation and shielding in photon fields.
Eklund K; Ahnesjö A
Med Phys; 2010 Nov; 37(11):6055-60. PubMed ID: 21158317
[TBL] [Abstract][Full Text] [Related]
6. Design and experimental testing of air slab caps which convert commercial electron diodes into dual purpose, correction-free diodes for small field dosimetry.
Charles PH; Cranmer-Sargison G; Thwaites DI; Kairn T; Crowe SB; Pedrazzini G; Aland T; Kenny J; Langton CM; Trapp JV
Med Phys; 2014 Oct; 41(10):101701. PubMed ID: 25281940
[TBL] [Abstract][Full Text] [Related]
7. The use of 0.5r
Anusionwu PC; Alpuche Aviles JE; Pistorius S
J Appl Clin Med Phys; 2020 Jan; 21(1):117-126. PubMed ID: 31898872
[TBL] [Abstract][Full Text] [Related]
8. Spectral distribution of particle fluence in small field detectors and its implication on small field dosimetry.
Benmakhlouf H; Andreo P
Med Phys; 2017 Feb; 44(2):713-724. PubMed ID: 28032369
[TBL] [Abstract][Full Text] [Related]
9. Determination of the KQclinfclin,Qmsr fmsr correction factors for detectors used with an 800 MU/min CyberKnife(®) system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method.
Moignier C; Huet C; Makovicka L
Med Phys; 2014 Jul; 41(7):071702. PubMed ID: 24989371
[TBL] [Abstract][Full Text] [Related]
10. Limitations of silicon diodes for clinical electron dosimetry.
Song H; Ahmad M; Deng J; Chen Z; Yue NJ; Nath R
Radiat Prot Dosimetry; 2006; 120(1-4):56-9. PubMed ID: 16772305
[TBL] [Abstract][Full Text] [Related]
11. Interface perturbation effects in high-energy electron beams.
Verhaegen F
Phys Med Biol; 2003 Mar; 48(6):687-705. PubMed ID: 12699189
[TBL] [Abstract][Full Text] [Related]
12. Characterizing the response of miniature scintillation detectors when irradiated with proton beams.
Archambault L; Polf JC; Beaulieu L; Beddar S
Phys Med Biol; 2008 Apr; 53(7):1865-76. PubMed ID: 18364543
[TBL] [Abstract][Full Text] [Related]
13. Monte Carlo calculations of electron beam quality conversion factors for several ion chamber types.
Muir BR; Rogers DW
Med Phys; 2014 Nov; 41(11):111701. PubMed ID: 25370615
[TBL] [Abstract][Full Text] [Related]
14. Effective point of measurement of thimble ion chambers in megavoltage photon beams.
Tessier F; Kawrakow I
Med Phys; 2010 Jan; 37(1):96-107. PubMed ID: 20175470
[TBL] [Abstract][Full Text] [Related]
15. Silicon diodes as an alternative to diamond detectors for depth dose curves and profile measurements of photon and electron radiation.
Scherf C; Peter C; Moog J; Licher J; Kara E; Zink K; Rödel C; Ramm U
Strahlenther Onkol; 2009 Aug; 185(8):530-6. PubMed ID: 19652937
[TBL] [Abstract][Full Text] [Related]
16. Monte Carlo study of the depth-dependent fluence perturbation in parallel-plate ionization chambers in electron beams.
Zink K; Czarnecki D; Looe HK; von Voigts-Rhetz P; Harder D
Med Phys; 2014 Nov; 41(11):111707. PubMed ID: 25370621
[TBL] [Abstract][Full Text] [Related]
17. Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams.
Tzedakis A; Damilakis JE; Mazonakis M; Stratakis J; Varveris H; Gourtsoyiannis N
Med Phys; 2004 Apr; 31(4):907-13. PubMed ID: 15125009
[TBL] [Abstract][Full Text] [Related]
18. Monte Carlo simulation of backscatter from lead for clinical electron beams using EGSnrc.
Chow JC; Grigorov GN
Med Phys; 2008 Apr; 35(4):1241-50. PubMed ID: 18491516
[TBL] [Abstract][Full Text] [Related]
19. On the effective point of measurement in megavoltage photon beams.
Kawrakow I
Med Phys; 2006 Jun; 33(6):1829-39. PubMed ID: 16872090
[TBL] [Abstract][Full Text] [Related]
20. Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation.
Wang LL; Rogers DW
Med Phys; 2008 May; 35(5):1747-55. PubMed ID: 18561649
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]