BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

861 related articles for article (PubMed ID: 21992382)

  • 1. Region-of-interest material decomposition from truncated energy-resolved CT.
    Schmidt TG; Pektas F
    Med Phys; 2011 Oct; 38(10):5657-66. PubMed ID: 21992382
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A neural network-based method for spectral distortion correction in photon counting x-ray CT.
    Touch M; Clark DP; Barber W; Badea CT
    Phys Med Biol; 2016 Aug; 61(16):6132-53. PubMed ID: 27469292
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photon counting spectral CT: improved material decomposition with K-edge-filtered x-rays.
    Shikhaliev PM
    Phys Med Biol; 2012 Mar; 57(6):1595-615. PubMed ID: 22398007
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CT energy weighting in the presence of scatter and limited energy resolution.
    Schmidt TG
    Med Phys; 2010 Mar; 37(3):1056-67. PubMed ID: 20384241
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Energy-resolved computed tomography: first experimental results.
    Shikhaliev PM
    Phys Med Biol; 2008 Oct; 53(20):5595-613. PubMed ID: 18799830
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Photon counting x-ray imaging with K-edge filtered x-rays: A simulation study.
    Atak H; Shikhaliev PM
    Med Phys; 2016 Mar; 43(3):1385-400. PubMed ID: 26936723
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Synthetic CT: simulating low dose single and dual energy protocols from a dual energy scan.
    Wang AS; Pelc NJ
    Med Phys; 2011 Oct; 38(10):5551-62. PubMed ID: 21992373
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Constrained one-step material decomposition reconstruction of head CT data from a silicon photon-counting prototype.
    Schmidt TG; Sidky EY; Pan X; Barber RF; Grönberg F; Sjölin M; Danielsson M
    Med Phys; 2023 Oct; 50(10):6008-6021. PubMed ID: 37523258
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Sensitivity of photon-counting based K-edge imaging in X-ray computed tomography.
    Roessl E; Brendel B; Engel KJ; Schlomka JP; Thran A; Proksa R
    IEEE Trans Med Imaging; 2011 Sep; 30(9):1678-90. PubMed ID: 21507770
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A general framework of noise suppression in material decomposition for dual-energy CT.
    Petrongolo M; Dong X; Zhu L
    Med Phys; 2015 Aug; 42(8):4848-62. PubMed ID: 26233212
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Image-based spectral distortion correction for photon-counting x-ray detectors.
    Ding H; Molloi S
    Med Phys; 2012 Apr; 39(4):1864-76. PubMed ID: 22482608
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Iterative image-domain decomposition for dual-energy CT.
    Niu T; Dong X; Petrongolo M; Zhu L
    Med Phys; 2014 Apr; 41(4):041901. PubMed ID: 24694132
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultralow-dose chest computed tomography for pulmonary nodule detection: first performance evaluation of single energy scanning with spectral shaping.
    Gordic S; Morsbach F; Schmidt B; Allmendinger T; Flohr T; Husarik D; Baumueller S; Raupach R; Stolzmann P; Leschka S; Frauenfelder T; Alkadhi H
    Invest Radiol; 2014 Jul; 49(7):465-73. PubMed ID: 24598443
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Monte Carlo simulation study of the effect of energy windows in computed tomography images based on an energy-resolved photon counting detector.
    Lee SW; Choi YN; Cho HM; Lee YJ; Ryu HJ; Kim HJ
    Phys Med Biol; 2012 Aug; 57(15):4931-49. PubMed ID: 22800966
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimal "image-based" weighting for energy-resolved CT.
    Schmidt TG
    Med Phys; 2009 Jul; 36(7):3018-27. PubMed ID: 19673201
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Eigenvector decomposition of full-spectrum x-ray computed tomography.
    Gonzales BJ; Lalush DS
    Phys Med Biol; 2012 Mar; 57(5):1309-23. PubMed ID: 22343097
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization.
    Dong X; Niu T; Zhu L
    Med Phys; 2014 May; 41(5):051909. PubMed ID: 24784388
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography.
    Schlomka JP; Roessl E; Dorscheid R; Dill S; Martens G; Istel T; Bäumer C; Herrmann C; Steadman R; Zeitler G; Livne A; Proksa R
    Phys Med Biol; 2008 Aug; 53(15):4031-47. PubMed ID: 18612175
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Implementation of dual- and triple-energy cone-beam micro-CT for postreconstruction material decomposition.
    Granton PV; Pollmann SI; Ford NL; Drangova M; Holdsworth DW
    Med Phys; 2008 Nov; 35(11):5030-42. PubMed ID: 19070237
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computed tomography with energy-resolved detection: a feasibility study.
    Shikhaliev PM
    Phys Med Biol; 2008 Mar; 53(5):1475-95. PubMed ID: 18296774
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 44.