BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

522 related articles for article (PubMed ID: 21992396)

  • 1. Development of activity pencil beam algorithm using measured distribution data of positron emitter nuclei generated by proton irradiation of targets containing (12)C, (16)O, and (40)Ca nuclei in preparation of clinical application.
    Miyatake A; Nishio T; Ogino T
    Med Phys; 2011 Oct; 38(10):5818-29. PubMed ID: 21992396
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Application of activity pencil beam algorithm using measured distribution data of positron emitter nuclei for therapeutic SOBP proton beam.
    Miyatake A; Nishio T
    Med Phys; 2013 Sep; 40(9):091709. PubMed ID: 24007142
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Measurement and verification of positron emitter nuclei generated at each treatment site by target nuclear fragment reactions in proton therapy.
    Miyatake A; Nishio T; Ogino T; Saijo N; Esumi H; Uesaka M
    Med Phys; 2010 Aug; 37(8):4445-55. PubMed ID: 20879603
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Distributions of beta+ decayed nuclei generated in the CH2 and H2O targets by the target nuclear fragment reaction using therapeutic MONO and SOBP proton beam.
    Nishio T; Sato T; Kitamura H; Murakami K; Ogino T
    Med Phys; 2005 Apr; 32(4):1070-82. PubMed ID: 15895592
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The development and clinical use of a beam ON-LINE PET system mounted on a rotating gantry port in proton therapy.
    Nishio T; Miyatake A; Ogino T; Nakagawa K; Saijo N; Esumi H
    Int J Radiat Oncol Biol Phys; 2010 Jan; 76(1):277-86. PubMed ID: 20005459
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dose-volume delivery guided proton therapy using beam on-line PET system.
    Nishio T; Ogino T; Nomura K; Uchida H
    Med Phys; 2006 Nov; 33(11):4190-7. PubMed ID: 17153398
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An analytical dose-averaged LET calculation algorithm considering the off-axis LET enhancement by secondary protons for spot-scanning proton therapy.
    Hirayama S; Matsuura T; Ueda H; Fujii Y; Fujii T; Takao S; Miyamoto N; Shimizu S; Fujimoto R; Umegaki K; Shirato H
    Med Phys; 2018 Jul; 45(7):3404-3416. PubMed ID: 29788552
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Very high-energy electron dose calculation using the Fermi-Eyges theory of multiple scattering and a simplified pencil beam model.
    Ronga MG; Deut U; Bonfrate A; De Marzi L
    Med Phys; 2023 Dec; 50(12):8009-8022. PubMed ID: 37730956
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Experimental evaluation of a spatial resampling technique to improve the accuracy of pencil-beam dose calculation in proton therapy.
    Egashira Y; Nishio T; Matsuura T; Kameoka S; Uesaka M
    Med Phys; 2012 Jul; 39(7):4104-14. PubMed ID: 22830743
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A pencil beam algorithm for helium ion beam therapy.
    Fuchs H; Strobele J; Schreiner T; Hirtl A; Georg D
    Med Phys; 2012 Nov; 39(11):6726-37. PubMed ID: 23127066
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries.
    Westerly DC; Mo X; Tomé WA; Mackie TR; DeLuca PM
    Med Phys; 2013 Jun; 40(6):061706. PubMed ID: 23718585
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of the influence of double and triple Gaussian proton kernel models on accuracy of dose calculations for spot scanning technique.
    Hirayama S; Takayanagi T; Fujii Y; Fujimoto R; Fujitaka S; Umezawa M; Nagamine Y; Hosaka M; Yasui K; Omachi C; Toshito T
    Med Phys; 2016 Mar; 43(3):1437-50. PubMed ID: 26936728
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Oblique incidence for broad monoenergetic proton beams.
    Jette D; Yuan J; Chen W
    Med Phys; 2010 Nov; 37(11):5683-90. PubMed ID: 21158280
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A proton dose calculation algorithm for conformal therapy simulations based on Molière's theory of lateral deflections.
    Deasy JO
    Med Phys; 1998 Apr; 25(4):476-83. PubMed ID: 9571613
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of a pencil-beam dose calculation technique for charged particle radiotherapy.
    Petti PL
    Int J Radiat Oncol Biol Phys; 1996 Jul; 35(5):1049-57. PubMed ID: 8751415
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental verification of the utility of positron emitter nuclei generated by photonuclear reactions for X-ray beam monitoring in a phantom.
    Nishio T; Inaniwa T; Inoue K; Miyatake A; Nakagawa K; Yoda K; Ogino T
    Radiat Med; 2007 Dec; 25(10):516-22. PubMed ID: 18085402
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A fourier analysis on the maximum acceptable grid size for discrete proton beam dose calculation.
    Li HS; Romeijn HE; Dempsey JF
    Med Phys; 2006 Sep; 33(9):3508-18. PubMed ID: 17022247
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Proton loss model for therapeutic beam dose calculations.
    Sandison GA; Chvetsov AV
    Med Phys; 2000 Sep; 27(9):2133-45. PubMed ID: 11011743
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a golden beam data set for the commissioning of a proton double-scattering system in a pencil-beam dose calculation algorithm.
    Slopsema RL; Lin L; Flampouri S; Yeung D; Li Z; McDonough JE; Palta J
    Med Phys; 2014 Sep; 41(9):091710. PubMed ID: 25186385
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pencil-beam redefinition algorithm for electron dose distributions.
    Shiu AS; Hogstrom KR
    Med Phys; 1991; 18(1):7-18. PubMed ID: 2008174
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.