These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
176 related articles for article (PubMed ID: 21997780)
1. The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles. Billi F; Benya P; Kavanaugh A; Adams J; Ebramzadeh E; McKellop H Clin Orthop Relat Res; 2012 Feb; 470(2):329-38. PubMed ID: 21997780 [TBL] [Abstract][Full Text] [Related]
2. The John Charnley Award: an accurate and extremely sensitive method to separate, display, and characterize wear debris: part 2: metal and ceramic particles. Billi F; Benya P; Kavanaugh A; Adams J; McKellop H; Ebramzadeh E Clin Orthop Relat Res; 2012 Feb; 470(2):339-50. PubMed ID: 21932105 [TBL] [Abstract][Full Text] [Related]
3. An easy technique to digest and isolate UHMWPE wear particles from a hip joint simulator. Affatato S; Emiliani D; Bersaglia G; Traina F; Toni A Int J Artif Organs; 2004 May; 27(5):424-32. PubMed ID: 15202822 [TBL] [Abstract][Full Text] [Related]
4. Comparison of three joint simulator wear debris isolation techniques: acid digestion, base digestion, and enzyme cleavage. Niedzwiecki S; Klapperich C; Short J; Jani S; Ries M; Pruitt L J Biomed Mater Res; 2001 Aug; 56(2):245-9. PubMed ID: 11340595 [TBL] [Abstract][Full Text] [Related]
5. Scanning Electron Microscopy and Energy-Dispersive X-Ray Spectroscopy as a Valuable Tool to Investigate the Ultra-High-Molecular-Weight Polyethylene Wear Mechanisms and Debris in Hip Implants. Schappo H; Gindri IM; Cubillos PO; Maru MM; Salmoria GV; Roesler CRM J Arthroplasty; 2018 Jan; 33(1):258-262. PubMed ID: 28844766 [TBL] [Abstract][Full Text] [Related]
6. Isolation and morphological characterisation of UHMWPE wear debris generated in vitro. Affatato S; Fernandes B; Tucci A; Esposito L; Toni A Biomaterials; 2001 Sep; 22(17):2325-31. PubMed ID: 11511029 [TBL] [Abstract][Full Text] [Related]
7. The performance of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: wear particle characteristics with isolation protocols. Affatato S; Bersaglia G; Emiliani D; Foltran I; Taddei P; Reggiani M; Ferrieri P; Toni A Biomaterials; 2003 Oct; 24(22):4045-55. PubMed ID: 12834600 [TBL] [Abstract][Full Text] [Related]
8. Isolation of predominantly submicron-sized UHMWPE wear particles from periprosthetic tissues. Campbell P; Ma S; Yeom B; McKellop H; Schmalzried TP; Amstutz HC J Biomed Mater Res; 1995 Jan; 29(1):127-31. PubMed ID: 7713952 [TBL] [Abstract][Full Text] [Related]
9. Wear behaviour of cross-linked polyethylene assessed in vitro under severe conditions. Affatato S; Bersaglia G; Rocchi M; Taddei P; Fagnano C; Toni A Biomaterials; 2005 Jun; 26(16):3259-67. PubMed ID: 15603821 [TBL] [Abstract][Full Text] [Related]
10. Grafting of poly(2-methacryloyloxyethyl phosphorylcholine) on polyethylene liner in artificial hip joints reduces production of wear particles. Moro T; Kyomoto M; Ishihara K; Saiga K; Hashimoto M; Tanaka S; Ito H; Tanaka T; Oshima H; Kawaguchi H; Takatori Y J Mech Behav Biomed Mater; 2014 Mar; 31():100-6. PubMed ID: 23651567 [TBL] [Abstract][Full Text] [Related]
11. Analysis of polyethylene particles produced in different wear conditions in vitro. Calonius O; Saikko V Clin Orthop Relat Res; 2002 Jun; (399):219-30. PubMed ID: 12011713 [TBL] [Abstract][Full Text] [Related]
17. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. McKellop H; Shen FW; Lu B; Campbell P; Salovey R J Orthop Res; 1999 Mar; 17(2):157-67. PubMed ID: 10221831 [TBL] [Abstract][Full Text] [Related]
18. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Goldsmith AA; Dowson D; Isaac GH; Lancaster JG Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049 [TBL] [Abstract][Full Text] [Related]
19. A novel method for isolation and recovery of ceramic nanoparticles and metal wear debris from serum lubricants at ultra-low wear rates. Lal S; Hall RM; Tipper JL Acta Biomater; 2016 Sep; 42():420-428. PubMed ID: 27395827 [TBL] [Abstract][Full Text] [Related]
20. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. Urban RM; Jacobs JJ; Tomlinson MJ; Gavrilovic J; Black J; Peoc'h M J Bone Joint Surg Am; 2000 Apr; 82(4):457-76. PubMed ID: 10761937 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]