40 related articles for article (PubMed ID: 21997977)
1. Variable bright-darkfield-contrast, a new illumination technique for improved visualizations of complex structured transparent specimens.
Piper T; Piper J
Microsc Res Tech; 2012 Apr; 75(4):537-54. PubMed ID: 21997977
[TBL] [Abstract][Full Text] [Related]
2. Planar photonic chips with tailored angular transmission for high-contrast-imaging devices.
Kuai Y; Chen J; Fan Z; Zou G; Lakowicz JR; Zhang D
Nat Commun; 2021 Nov; 12(1):6835. PubMed ID: 34824261
[TBL] [Abstract][Full Text] [Related]
3. Applications of reflection-contrast microscopy, including the sensitive detection of the results of in situ hybridisation a review.
Ploem J
J Microsc; 2019 May; 274(2):79-86. PubMed ID: 30720204
[TBL] [Abstract][Full Text] [Related]
4. An apparatus for qualitative assessment of the shading ratio of oblique illumination and real-time high-contrast imaging.
Shao M; Wang K; Wang Z; Peng T; Zhang S; Zhang J; Fang S; Wang F; Zhang S; Zhong MC; Wang Y; Zhong Z; Zhou J
J Biophotonics; 2022 Dec; 15(12):e202200122. PubMed ID: 36029217
[TBL] [Abstract][Full Text] [Related]
5. Cost-effective side-illumination darkfield nanoplasmonic marker microscopy.
Qi M; Darviot C; Patskovsky S; Meunier M
Analyst; 2019 Feb; 144(4):1303-1308. PubMed ID: 30560253
[TBL] [Abstract][Full Text] [Related]
6. LED array reflectance microscopy for scattering-based multi-contrast imaging.
Song W; Matlock A; Fu S; Qin X; Feng H; Gabel CV; Tian L; Yi J
Opt Lett; 2020 Apr; 45(7):1647-1650. PubMed ID: 32235964
[TBL] [Abstract][Full Text] [Related]
7. ROCS microscopy with distinct zero-order blocking.
Mahmud MS; Ruh D; Rohrbach A
Opt Express; 2022 Dec; 30(25):44339-44349. PubMed ID: 36522860
[TBL] [Abstract][Full Text] [Related]
8. Use of topical methylene blue to image nuclear morphometry with a low-cost scanning darkfield microendoscope.
Hou H; Carns J; Schwarz RA; Gillenwater AM; Anandasabapathy S; Richards-Kortum RR
J Biomed Opt; 2024 May; 29(5):050501. PubMed ID: 38774711
[TBL] [Abstract][Full Text] [Related]
9. Three-dimensional real-time darkfield imaging through Fourier lightfield microscopy.
Scrofani G; Saavedra G; Martínez-Corral M; Sánchez-Ortiga E
Opt Express; 2020 Oct; 28(21):30513-30519. PubMed ID: 33115051
[TBL] [Abstract][Full Text] [Related]
10. Scanning darkfield high-resolution microendoscope for label-free microvascular imaging.
Hou H; Tang Y; Coole JB; Kortum A; Schwarz RA; Carns J; Gillenwater AM; Ramalingam P; Milbourne A; Salcedo MP; Schmeler KM; Richards-Kortum RR
Biomed Opt Express; 2023 Oct; 14(10):5097-5112. PubMed ID: 37854554
[TBL] [Abstract][Full Text] [Related]
11. Robust full-pose-parameter estimation for the LED array in Fourier ptychographic microscopy.
Zheng C; Zhang S; Yang D; Zhou G; Hu Y; Hao Q
Biomed Opt Express; 2022 Aug; 13(8):4468-4482. PubMed ID: 36032585
[TBL] [Abstract][Full Text] [Related]
12. Luminescent Surfaces with Tailored Angular Emission for Compact Dark-Field Imaging Devices.
Chazot CAC; Nagelberg S; Rowlands CJ; Scherer MRJ; Coropceanu I; Broderick K; Kim Y; Bawendi MG; So P; Kolle M
Nat Photonics; 2020 May; 14(5):310-315. PubMed ID: 33584848
[TBL] [Abstract][Full Text] [Related]
13. Image simulation for biological microscopy: microlith.
Mehta SB; Oldenbourg R
Biomed Opt Express; 2014 Jun; 5(6):1822-38. PubMed ID: 24940543
[TBL] [Abstract][Full Text] [Related]
14. Single-objective selective-volume illumination microscopy enables high-contrast light-field imaging.
Madaan S; Keomanee-Dizon K; Jones M; Zhong C; Nadtochiy A; Luu P; Fraser SE; Truong TV
Opt Lett; 2021 Jun; 46(12):2860-2863. PubMed ID: 34129559
[TBL] [Abstract][Full Text] [Related]
15. Principal component analysis-based quantitative differential interference contrast microscopy.
Wei Q; Li Y; Vargas J; Wang J; Gong Q; Kong Y; Jiang Z; Xue L; Liu C; Liu F; Wang S
Opt Lett; 2019 Jan; 44(1):45-48. PubMed ID: 30645544
[TBL] [Abstract][Full Text] [Related]
16. Reflection light-field microscope with a digitally tunable aperture by single-pixel imaging.
Yao M; Cheng J; Huang Z; Zhang Z; Li S; Peng J; Zhong J
Opt Express; 2019 Nov; 27(23):33040-33050. PubMed ID: 31878378
[TBL] [Abstract][Full Text] [Related]
17. Acceptance Angle Control for Improved Transmission Imaging in an SEM.
Holm J; Keller RR
Micros Today; 2017 Mar; 25(2):12-19. PubMed ID: 29375278
[TBL] [Abstract][Full Text] [Related]
18. Fabrication and validation of an LED array microscope for multimodal, quantitative imaging.
Moustafa TE; Polanco ER; Belote RL; Judson-Torres RL; Zangle TA
HardwareX; 2023 Mar; 13():e00399. PubMed ID: 36756350
[TBL] [Abstract][Full Text] [Related]
19. Adaptive phase contrast microscopy to compensate for the meniscus effect.
Nienhaus F; Piotrowski T; Nießing B; König N; Schmitt RH
Sci Rep; 2023 Apr; 13(1):5785. PubMed ID: 37031241
[TBL] [Abstract][Full Text] [Related]
20. AbsorbanceQ: An App for Generating Absorbance Images from Brightfield Images.
Zimmerman SM; Simon CG; Babakhanova G
J Res Natl Inst Stand Technol; 2021; 126():126039. PubMed ID: 36475084
[No Abstract] [Full Text] [Related]
[Next] [New Search]