BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

182 related articles for article (PubMed ID: 22000575)

  • 21. Cementless total hip arthroplasty with large diameter metal-on-metal heads: short-term survivorship of 8059 hips from the Finnish Arthroplasty Register.
    Mokka J; Mäkelä KT; Virolainen P; Remes V; Pulkkinen P; Eskelinen A
    Scand J Surg; 2013; 102(2):117-23. PubMed ID: 23820688
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Early results of total hip replacement with the Metasul metal-on-metal cementless prosthesis.
    Vigler M; Greental A; Kaminsky AJ; Shauer L; Salai M; Soudry M
    Bull NYU Hosp Jt Dis; 2010; 68(1):11-4. PubMed ID: 20345355
    [TBL] [Abstract][Full Text] [Related]  

  • 23. High rate of revision and a high incidence of radiolucent lines around Metasul metal-on-metal total hip replacements: results from a randomised controlled trial of three bearings after seven years.
    Bjorgul K; Novicoff WN; Andersen ST; Ahlund OR; Bunes A; Wiig M; Brevig K
    Bone Joint J; 2013 Jul; 95-B(7):881-6. PubMed ID: 23814237
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Poor short term outcome with a metal-on-metal total hip arthroplasty.
    Levy YD; Ezzet KA
    J Arthroplasty; 2013 Aug; 28(7):1212-7. PubMed ID: 23538122
    [TBL] [Abstract][Full Text] [Related]  

  • 25. An analysis of stably fixed femoral components retained during revision total hip arthroplasty.
    Cho HJ; Han SB; Park JH; Park SW
    J Arthroplasty; 2011 Dec; 26(8):1239-44. PubMed ID: 21435820
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Total hip arthroplasty with a cemented, polished, collared femoral stem and a cementless acetabular component. A follow-up study at a minimum of ten years.
    Firestone DE; Callaghan JJ; Liu SS; Goetz DD; Sullivan PM; Vittetoe DA; Johnston RC
    J Bone Joint Surg Am; 2007 Jan; 89(1):126-32. PubMed ID: 17200319
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Long-term results of the CLS acetabular cup in primary total hip replacement].
    Rozkydal Z; Janícek P; Tomás T; Florian Z
    Acta Chir Orthop Traumatol Cech; 2009 Apr; 76(2):90-7. PubMed ID: 19439127
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Outcomes of the Recalled Articular Surface Replacement Metal-on-Metal Hip Implant System: A Systematic Review.
    Laaksonen I; Donahue GS; Madanat R; Makela KT; Malchau H
    J Arthroplasty; 2017 Jan; 32(1):341-346. PubMed ID: 27546469
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Revision total hip arthroplasty for ceramic head fracture: a long-term follow-up.
    Sharma V; Ranawat AS; Rasquinha VJ; Weiskopf J; Howard H; Ranawat CS
    J Arthroplasty; 2010 Apr; 25(3):342-7. PubMed ID: 20347713
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A well-fixed femoral stem facing a failed acetabular component: to exchange or not? A 5- to 15-year follow-up study.
    de Thomasson E; Conso C; Mazel C
    Orthop Traumatol Surg Res; 2012 Feb; 98(1):24-9. PubMed ID: 22245150
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Is metal-on-metal squeaking related to acetabular angle of inclination?
    Bernasek T; Fisher D; Dalury D; Levering M; Dimitris K
    Clin Orthop Relat Res; 2011 Sep; 469(9):2577-82. PubMed ID: 21512812
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Gender is a significant factor for failure of metal-on-metal total hip arthroplasty.
    Latteier MJ; Berend KR; Lombardi AV; Ajluni AF; Seng BE; Adams JB
    J Arthroplasty; 2011 Sep; 26(6 Suppl):19-23. PubMed ID: 21641761
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Femoral revision in hip resurfacing compared with large-bearing metal-on-metal hip arthroplasty.
    Garrett SJ; Bolland BJ; Yates PJ; Gardner EM; Latham JM
    J Arthroplasty; 2011 Dec; 26(8):1214-8. PubMed ID: 21414749
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Radiographically undetectable periprosthetic osteolysis with ASR implants: the implication of blood metal ions.
    Randelli F; Banci L; Favilla S; Maglione D; Aliprandi A
    J Arthroplasty; 2013 Sep; 28(8):1259-64. PubMed ID: 23528557
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Radiographic evaluation of midterm failure rates following metal-on-metal hip resurfacing.
    Rylander LS; Milbrandt JC; Wallace AB; Allan DG
    J Arthroplasty; 2011 Sep; 26(6):897-902. PubMed ID: 21131164
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Total hip arthroplasty with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis.
    Wu LD; Jin LB; Yan SG; Yang QS; Dai XS; Wang XH
    Chin J Traumatol; 2004 Oct; 7(5):280-5. PubMed ID: 15363221
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Long-term results of the ABG-1 hydroxyapatite coated total hip arthroplasty: analysis of 111 cases with a minimum follow-up of 10 years.
    Bidar R; Kouyoumdjian P; Munini E; Asencio G
    Orthop Traumatol Surg Res; 2009 Dec; 95(8):579-87. PubMed ID: 19926546
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty. Apropos of 106 cases.
    Beldame J; Carreras F; Oger P; Beaufils P
    Orthop Traumatol Surg Res; 2009 Nov; 95(7):478-90. PubMed ID: 19801209
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Metal-on-metal hip resurfacing compared with 28-mm diameter metal-on-metal total hip replacement: a randomised study with six to nine years' follow-up.
    Vendittoli PA; Rivière C; Roy AG; Barry J; Lusignan D; Lavigne M
    Bone Joint J; 2013 Nov; 95-B(11):1464-73. PubMed ID: 24151264
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Osteolysis with a cementless second generation metal-on-metal cup in total hip replacement.
    Holloway I; Walter WL; Zicat B; Walter WK
    Int Orthop; 2009 Dec; 33(6):1537-42. PubMed ID: 18985349
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.