BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

873 related articles for article (PubMed ID: 22004933)

  • 1. Physiologic and dosimetric considerations for limiting electric fields induced in the body by movement in a static magnetic field.
    Jokela K; Saunders RD
    Health Phys; 2011 Jun; 100(6):641-53. PubMed ID: 22004933
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computational estimation of magnetically induced electric fields in a rotating head.
    Ilvonen S; Laakso I
    Phys Med Biol; 2009 Jan; 54(2):341-51. PubMed ID: 19098349
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of complex EMF exposure situations including inhomogeneous field distribution.
    Jokela K
    Health Phys; 2007 Jun; 92(6):531-40. PubMed ID: 17495653
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computational dosimetry of induced electric fields during realistic movements in the vicinity of a 3 T MRI scanner.
    Laakso I; Kännälä S; Jokela K
    Phys Med Biol; 2013 Apr; 58(8):2625-40. PubMed ID: 23552657
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Children and adults exposed to low-frequency magnetic fields at the ICNIRP reference levels: theoretical assessment of the induced electric fields.
    Bakker JF; Paulides MM; Neufeld E; Christ A; Chen XL; Kuster N; van Rhoon GC
    Phys Med Biol; 2012 Apr; 57(7):1815-29. PubMed ID: 22411059
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of electric fields induced in a human subject due to natural movements in static magnetic fields or exposure to alternating magnetic field gradients.
    Glover PM; Bowtell R
    Phys Med Biol; 2008 Jan; 53(2):361-73. PubMed ID: 18184992
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Health effects of occupational exposure to static magnetic fields used in magnetic resonance imaging: a review].
    Franco G; Perduri R; Murolo A
    Med Lav; 2008; 99(1):16-28. PubMed ID: 18254536
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Occupational exposure measurements of static and pulsed gradient magnetic fields in the vicinity of MRI scanners.
    Kännälä S; Toivo T; Alanko T; Jokela K
    Phys Med Biol; 2009 Apr; 54(7):2243-57. PubMed ID: 19293469
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Numerical study of currents in workers induced by body-motion around high-ultrahigh field MRI magnets.
    ; Trakic A; Wang H; Liu F
    J Magn Reson Imaging; 2007 Nov; 26(5):1261-77. PubMed ID: 17969138
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of biological effects, dosimetric models, and exposure assessment related to ELF electric- and magnetic-field guidelines.
    Kavet R; Stuchly MA; Bailey WH; Bracken TD
    Appl Occup Environ Hyg; 2001 Dec; 16(12):1118-38. PubMed ID: 11783873
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Static fields: biological effects and mechanisms relevant to exposure limits.
    van Rongen E; Saunders RD; van Deventer ET; Repacholi MH
    Health Phys; 2007 Jun; 92(6):584-90. PubMed ID: 17495659
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Numerical dosimetry ELF: accuracy of the method, variability of models and parameters, and the implication for quantifying guidelines.
    Bahr A; Bolz T; Hennes C
    Health Phys; 2007 Jun; 92(6):521-30. PubMed ID: 17495652
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments.
    Fuentes MA; Trakic A; Wilson SJ; Crozier S
    IEEE Trans Biomed Eng; 2008 Apr; 55(4):1355-64. PubMed ID: 18390326
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Dosimetric Uncertainties: Magnetic Field Coupling to Peripheral Nerve.
    Kavet R
    Health Phys; 2015 Dec; 109(6):556-65. PubMed ID: 26509623
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Current densities in a pregnant woman model induced by simultaneous ELF electric and magnetic field exposure.
    Cech R; Leitgeb N; Pediaditis M
    Phys Med Biol; 2008 Jan; 53(1):177-86. PubMed ID: 18182695
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Guidelines for limiting exposure to electric fields induced by movement of the human body in a static magnetic field and by time-varying magnetic fields below 1 Hz.
    International Commission on Non-Ionizing Radiation Protection (ICNIRP)
    Health Phys; 2014 Mar; 106(3):418-25. PubMed ID: 25208018
    [No Abstract]   [Full Text] [Related]  

  • 17. Computational analysis of thresholds for magnetophosphenes.
    Laakso I; Hirata A
    Phys Med Biol; 2012 Oct; 57(19):6147-65. PubMed ID: 22971612
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electric field induced in the human body by uniform 50 Hz electric or magnetic fields: bibliography analysis and method for conservatively deriving measurable limits.
    Magne I; Deschamps F
    J Radiol Prot; 2016 Sep; 36(3):419-436. PubMed ID: 27340133
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Occupational exposure to intermediate frequency and extremely low frequency magnetic fields among personnel working near electronic article surveillance systems.
    Roivainen P; Eskelinen T; Jokela K; Juutilainen J
    Bioelectromagnetics; 2014 May; 35(4):245-50. PubMed ID: 24615825
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Different basic dosimetric quantities for the characterization of exposure to low-frequency electric and magnetic fields and the implication for practical exposure conditions and guidelines.
    Martens L
    Health Phys; 2007 Jun; 92(6):515-20. PubMed ID: 17495651
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 44.