357 related articles for article (PubMed ID: 22005864)
1. Cemented all-polyethylene and metal-backed polyethylene tibial components used for primary total knee arthroplasty: a systematic review of the literature and meta-analysis of randomized controlled trials involving 1798 primary total knee implants.
Voigt J; Mosier M
J Bone Joint Surg Am; 2011 Oct; 93(19):1790-8. PubMed ID: 22005864
[TBL] [Abstract][Full Text] [Related]
2. All-polyethylene versus metal-backed tibial component in total knee arthroplasty.
Longo UG; Ciuffreda M; D'Andrea V; Mannering N; Locher J; Denaro V
Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3620-3636. PubMed ID: 27209191
[TBL] [Abstract][Full Text] [Related]
3. All-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register.
Gudnason A; Hailer NP; W-Dahl A; Sundberg M; Robertsson O
J Bone Joint Surg Am; 2014 Jun; 96(12):994-999. PubMed ID: 24951734
[TBL] [Abstract][Full Text] [Related]
4. A randomized comparison of all-polyethylene and metal-backed tibial components.
Gioe TJ; Bowman KR
Clin Orthop Relat Res; 2000 Nov; (380):108-15. PubMed ID: 11064980
[TBL] [Abstract][Full Text] [Related]
5. All-polyethylene vs. metal-backed tibial component in total knee arthroplasty-a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components: part 1. Horizontally cemented components: AP better fixated than MB.
Hyldahl H; Regnér L; Carlsson L; Kärrholm J; Weidenhielm L
Acta Orthop; 2005 Dec; 76(6):769-77. PubMed ID: 16470428
[TBL] [Abstract][Full Text] [Related]
6. All-polyethylene compared with metal-backed tibial components in total knee arthroplasty at ten years. A prospective, randomized controlled trial.
Bettinson KA; Pinder IM; Moran CG; Weir DJ; Lingard EA
J Bone Joint Surg Am; 2009 Jul; 91(7):1587-94. PubMed ID: 19571080
[TBL] [Abstract][Full Text] [Related]
7. A Meta-Analysis Comparing All-Polyethylene Tibial Component to Metal-Backed Tibial Component in Total Knee Arthroplasty: Assessing Survivorship and Functional Outcomes.
Voss B; El-Othmani MM; Schnur AK; Botchway A; Mihalko WM; Saleh KJ
J Arthroplasty; 2016 Nov; 31(11):2628-2636. PubMed ID: 27538714
[TBL] [Abstract][Full Text] [Related]
8. All-polyethylene vs. metal-backed tibial component in total knee arthroplasty-a randomized RSA study comparing early fixation of horizontally and completely cemented tibial components: part 2. Completely cemented components: MB not superior to AP components.
Hyldahl H; Regnér L; Carlsson L; Kärrholm J; Weidenhielm L
Acta Orthop; 2005 Dec; 76(6):778-84. PubMed ID: 16470429
[TBL] [Abstract][Full Text] [Related]
9. Metal-Backed Tibial Components Do Not Reduce Risk of Early Aseptic Loosening in Unicompartmental Knee Arthroplasty: A Systematic Review and Meta-Analysis.
Costa GG; Lo Presti M; Grassi A; Agrò G; Cialdella S; Mosca M; Caravelli S; Zaffagnini S
J Knee Surg; 2020 Feb; 33(2):180-189. PubMed ID: 30650439
[TBL] [Abstract][Full Text] [Related]
10. All-polyethylene versus metal-backed tibial components in total knee arthroplasty: a meta-analysis of randomized controlled trials.
Elmhiregh A; Abuodeh Y; Alzobi O; Zikria B; Alkhayarin M; Morrey BF
Eur J Orthop Surg Traumatol; 2023 Dec; 33(8):3611-3622. PubMed ID: 37249643
[TBL] [Abstract][Full Text] [Related]
11. Comparative Survivorship of Different Tibial Designs in Primary Total Knee Arthroplasty.
Kremers HM; Sierra RJ; Schleck CD; Berry DJ; Cabanela ME; Hanssen AD; Pagnano MW; Trousdale RT; Lewallen DG
J Bone Joint Surg Am; 2014 Jul; 96(14):e121. PubMed ID: 25031383
[TBL] [Abstract][Full Text] [Related]
12. Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty.
Van Hamersveld KT; Marang-Van De Mheen PJ; Nelissen RGHH; Toksvig-Larsen S
Acta Orthop; 2018 Aug; 89(4):412-417. PubMed ID: 29714073
[TBL] [Abstract][Full Text] [Related]
13. All-polyethylene tibial components in modern total knee arthroplasty.
Browne JA; Gall Sims SE; Giuseffi SA; Trousdale RT
J Am Acad Orthop Surg; 2011 Sep; 19(9):527-35. PubMed ID: 21885698
[TBL] [Abstract][Full Text] [Related]
14. All-polyethylene tibial components are equal to metal-backed components: systematic review and meta-regression.
Nouta KA; Verra WC; Pijls BG; Schoones JW; Nelissen RG
Clin Orthop Relat Res; 2012 Dec; 470(12):3549-59. PubMed ID: 22972656
[TBL] [Abstract][Full Text] [Related]
15. Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty.
Cheng T; Zhang G; Zhang X
Acta Orthop; 2011 Oct; 82(5):589-95. PubMed ID: 21895503
[TBL] [Abstract][Full Text] [Related]
16. Hydroxyapatite (HA) coating appears to be of benefit for implant durability of tibial components in primary total knee arthroplasty.
Voigt JD; Mosier M
Acta Orthop; 2011 Aug; 82(4):448-59. PubMed ID: 21657975
[TBL] [Abstract][Full Text] [Related]
17. All-polyethylene tibial components generate higher stress and micromotions than metal-backed tibial components in total knee arthroplasty.
Brihault J; Navacchia A; Pianigiani S; Labey L; De Corte R; Pascale V; Innocenti B
Knee Surg Sports Traumatol Arthrosc; 2016 Aug; 24(8):2550-9. PubMed ID: 25957612
[TBL] [Abstract][Full Text] [Related]
18. Metal or Modularity: Why Do Metal-Backed Tibias Have Inferior Outcomes to All-Polyethylene Tibial Components in Patients With Osteoarthritis.
Houdek MT; Watts CD; Wyles CC; Martin JR; Trousdale RT; Taunton MJ
J Arthroplasty; 2017 Mar; 32(3):836-842. PubMed ID: 27816367
[TBL] [Abstract][Full Text] [Related]
19. Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?
Cheng T; Pan X; Liu T; Zhang X
Knee Surg Sports Traumatol Arthrosc; 2012 Aug; 20(8):1438-49. PubMed ID: 21971938
[TBL] [Abstract][Full Text] [Related]
20. A randomised controlled trial of the clinical effectiveness and cost-effectiveness of different knee prostheses: the Knee Arthroplasty Trial (KAT).
Murray DW; MacLennan GS; Breeman S; Dakin HA; Johnston L; Campbell MK; Gray AM; Fiddian N; Fitzpatrick R; Morris RW; Grant AM;
Health Technol Assess; 2014 Mar; 18(19):1-235, vii-viii. PubMed ID: 24679222
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]