BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

573 related articles for article (PubMed ID: 22011631)

  • 1. Infection after spanning external fixation for high-energy tibial plateau fractures: is pin site-plate overlap a problem?
    Laible C; Earl-Royal E; Davidovitch R; Walsh M; Egol KA
    J Orthop Trauma; 2012 Feb; 26(2):92-7. PubMed ID: 22011631
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Is the proximity of external fixator pins to eventual definitive fixation implants related to the risk of deep infection in the staged management of tibial pilon fractures?
    Potter JM; van der Vliet QMJ; Esposito JG; McTague MF; Weaver M; Heng M
    Injury; 2019 Nov; 50(11):2103-2107. PubMed ID: 31530380
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Is Definitive Plate Fixation Overlap With External Fixator Pin Sites a Risk Factor for Infection in Pilon Fractures?
    Dombrowsky A; Abyar E; McGwin G; Johnson M
    J Orthop Trauma; 2021 Jan; 35(1):e7-e12. PubMed ID: 32618814
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Definitive plates overlapping provisional external fixator pin sites: is the infection risk increased?
    Shah CM; Babb PE; McAndrew CM; Brimmo O; Badarudeen S; Tornetta P; Ricci WM; Gardner MJ
    J Orthop Trauma; 2014 Sep; 28(9):518-22. PubMed ID: 24531389
    [TBL] [Abstract][Full Text] [Related]  

  • 5. External fixator pin placement during initial management of tibial plateau fractures: are there parameters to minimize pin-plate overlap?
    Haase DR; Haase LR; Moon TJ; Trotter M; Napora JK; Wise BT
    Eur J Orthop Surg Traumatol; 2023 Jul; 33(5):1827-1833. PubMed ID: 35982192
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Does Early versus Delayed Spanning External Fixation Impact Complication Rates for High-energy Tibial Plateau and Plafond Fractures?
    Haller JM; Holt D; Rothberg DL; Kubiak EN; Higgins TF
    Clin Orthop Relat Res; 2016 Jun; 474(6):1436-44. PubMed ID: 26481122
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Is pin-plate overlap in tibial plateau fractures associated with increased infection rates?
    Haase LR; Haase DR; Moon TJ; Clary SJ; Nelson GB; Ochenjele G; Wise BT; Napora JK
    Injury; 2022 Apr; 53(4):1504-1509. PubMed ID: 35067341
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Comparison study on locking compress plate external fixator and standard external fixator for treatment of tibial open fractures].
    Wu G; Luo X; Tan L; Lin X; Wu C; Guo Y; Zhong Z
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Nov; 27(11):1291-5. PubMed ID: 24501884
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Metaphyseal locking plate as a definitive external fixator for treating open tibial fractures--clinical outcome and a finite element study.
    Ma CH; Wu CH; Tu YK; Lin TS
    Injury; 2013 Aug; 44(8):1097-101. PubMed ID: 23706173
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Risk factors of infection after ORIF of bicondylar tibial plateau fractures.
    Morris BJ; Unger RZ; Archer KR; Mathis SL; Perdue AM; Obremskey WT
    J Orthop Trauma; 2013 Sep; 27(9):e196-200. PubMed ID: 23287757
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Does external fixator pin site distance from definitive implant affect infection rate in pilon fractures?
    Hadeed MM; Evans CL; Werner BC; Novicoff WM; Weiss DB
    Injury; 2019 Feb; 50(2):503-507. PubMed ID: 30409731
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome.
    Kim JW; Oh CW; Oh JK; Kyung HS; Park KH; Kim HJ; Jung JW; Jung YS
    Injury; 2017 Jun; 48(6):1190-1193. PubMed ID: 28320508
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Locking plate as a definitive external fixator for treating tibial fractures with compromised soft tissue envelop.
    Qiu XS; Yuan H; Zheng X; Wang JF; Xiong J; Chen YX
    Arch Orthop Trauma Surg; 2014 Mar; 134(3):383-8. PubMed ID: 24362495
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Do number and location of plates impact infection rates after definitive fixation of high energy tibial plateau fractures?
    Moon TJ; Haase L; Haase D; Ochenjele G; Wise B; Napora J
    Eur J Orthop Surg Traumatol; 2023 Jul; 33(5):1841-1847. PubMed ID: 35984517
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Retrospective review of tibial plateau fractures treated by two methods without staging.
    Conserva V; Vicenti G; Allegretti G; Filipponi M; Monno A; Picca G; Moretti B
    Injury; 2015 Oct; 46(10):1951-6. PubMed ID: 26243524
    [TBL] [Abstract][Full Text] [Related]  

  • 16. External Fixation Using a Locking Plate: A Reliable Way in Treating Distal Tibial Fractures.
    Zhang J; Ebraheim NA; Li M; He X; Liu J; Zhu L; Yu Y; Siddiqui S
    J Orthop Trauma; 2015 Nov; 29(11):e454-8. PubMed ID: 26492454
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Complications of high-energy bicondylar tibial plateau fractures treated with dual plating through 2 incisions.
    Ruffolo MR; Gettys FK; Montijo HE; Seymour RB; Karunakar MA
    J Orthop Trauma; 2015 Feb; 29(2):85-90. PubMed ID: 25050747
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Risk Factors for Deep Infection Following Plate Fixation of Proximal Tibial Fractures.
    Parkkinen M; Madanat R; Lindahl J; Mäkinen TJ
    J Bone Joint Surg Am; 2016 Aug; 98(15):1292-7. PubMed ID: 27489320
    [TBL] [Abstract][Full Text] [Related]  

  • 19. External fixation using femoral less invasive stabilization system plate in tibial proximal metaphyseal fracture.
    Zhang J; Ebraheim N; Li M; He X; Liu J; Zhu L; Yu Y
    Clin Orthop Surg; 2015 Mar; 7(1):8-14. PubMed ID: 25729513
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Metaphyseal locking plate as an external fixator for open tibial fracture: Clinical outcomes and biomechanical assessment.
    Ma CH; Wu CH; Jiang JR; Tu YK; Lin TS
    Injury; 2017 Feb; 48(2):501-505. PubMed ID: 27919511
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.