These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Rapid single-scan T2*-mapping using exponential excitation pulses and image-based correction for linear background gradients. Baudrexel S; Volz S; Preibisch C; Klein JC; Steinmetz H; Hilker R; Deichmann R Magn Reson Med; 2009 Jul; 62(1):263-8. PubMed ID: 19353655 [TBL] [Abstract][Full Text] [Related]
5. Limitations of skipping echoes for exponential T McPhee KC; Wilman AH J Magn Reson Imaging; 2018 Nov; 48(5):1432-1440. PubMed ID: 29687931 [TBL] [Abstract][Full Text] [Related]
6. Improving T2 -weighted imaging at high field through the use of kT -points. Eggenschwiler F; O'Brien KR; Gruetter R; Marques JP Magn Reson Med; 2014 Apr; 71(4):1478-88. PubMed ID: 23788025 [TBL] [Abstract][Full Text] [Related]
7. Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium single-pulse observation of T1 and T2. Deoni SC Magn Reson Med; 2011 Apr; 65(4):1021-35. PubMed ID: 21413066 [TBL] [Abstract][Full Text] [Related]
8. Influence of RF spoiling on the stability and accuracy of T1 mapping based on spoiled FLASH with varying flip angles. Preibisch C; Deichmann R Magn Reson Med; 2009 Jan; 61(1):125-35. PubMed ID: 19097220 [TBL] [Abstract][Full Text] [Related]
9. Fast 3D radiofrequency field mapping using echo-planar imaging. Jiru F; Klose U Magn Reson Med; 2006 Dec; 56(6):1375-9. PubMed ID: 17089359 [TBL] [Abstract][Full Text] [Related]
10. Transverse relaxation and flip angle mapping: Evaluation of simultaneous and independent methods using multiple spin echoes. McPhee KC; Wilman AH Magn Reson Med; 2017 May; 77(5):2057-2065. PubMed ID: 27367906 [TBL] [Abstract][Full Text] [Related]
11. Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast. Busse RF; Hariharan H; Vu A; Brittain JH Magn Reson Med; 2006 May; 55(5):1030-7. PubMed ID: 16598719 [TBL] [Abstract][Full Text] [Related]
12. Simple recipe for accurate T(2) quantification with multi spin-echo acquisitions. Neumann D; Blaimer M; Jakob PM; Breuer FA MAGMA; 2014 Dec; 27(6):567-77. PubMed ID: 24643838 [TBL] [Abstract][Full Text] [Related]
14. Noise robust spatially regularized myelin water fraction mapping with the intrinsic B1-error correction based on the linearized version of the extended phase graph model. Kumar D; Siemonsen S; Heesen C; Fiehler J; Sedlacik J J Magn Reson Imaging; 2016 Apr; 43(4):800-17. PubMed ID: 26477610 [TBL] [Abstract][Full Text] [Related]
15. Retrospective image correction in the presence of nonlinear temporal magnetic field changes using multichannel navigator echoes. Versluis MJ; Sutton BP; de Bruin PW; Börnert P; Webb AG; van Osch MJ Magn Reson Med; 2012 Dec; 68(6):1836-45. PubMed ID: 22362637 [TBL] [Abstract][Full Text] [Related]
16. Measurement and correction of transmitter and receiver induced nonuniformities in vivo. Wang J; Qiu M; Yang QX; Smith MB; Constable RT Magn Reson Med; 2005 Feb; 53(2):408-17. PubMed ID: 15678526 [TBL] [Abstract][Full Text] [Related]
17. Effects of B1 inhomogeneity correction for three-dimensional variable flip angle T1 measurements in hip dGEMRIC at 3 T and 1.5 T. Siversson C; Chan J; Tiderius CJ; Mamisch TC; Jellus V; Svensson J; Kim YJ Magn Reson Med; 2012 Jun; 67(6):1776-81. PubMed ID: 22135218 [TBL] [Abstract][Full Text] [Related]
18. Exponential excitation pulses for improved water content mapping in the presence of background gradients. Preibisch C; Volz S; Anti S; Deichmann R Magn Reson Med; 2008 Oct; 60(4):908-16. PubMed ID: 18816811 [TBL] [Abstract][Full Text] [Related]
19. Method of generalized projections algorithm for image-based reduction of artifacts in radial imaging. Lee KJ; Paley MN; Griffiths PD; Wild JM Magn Reson Med; 2005 Jul; 54(1):246-50. PubMed ID: 15968656 [TBL] [Abstract][Full Text] [Related]
20. Phase-sensitive, dual-acquisition, single-slab, 3D, turbo-spin-echo pulse sequence for simultaneous T2-weighted and fluid-attenuated whole-brain imaging. Park J; Park S; Kim EY; Suh JS Magn Reson Med; 2010 May; 63(5):1422-30. PubMed ID: 20432315 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]