These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 22015124)

  • 1. Device entrapment: a rare complication of percutaneous coronary intervention.
    Rehman A; Khan JA; Sial JA; Baloch ZH
    J Coll Physicians Surg Pak; 2011 Oct; 21(10):620-2. PubMed ID: 22015124
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Delayed surgical retrieval of retained guidewire following percutaneous coronary intervention.
    Modi A; Zorinas A; Vohra HA; Kaarne M
    J Card Surg; 2011 Jan; 26(1):46-8. PubMed ID: 21039856
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [A case report of entrapment of PTCA balloon catheter caused by its rupture].
    Nishiwaki N; Kawano Y; Furukawa K; Nakayama Y
    Nihon Kyobu Geka Gakkai Zasshi; 1991 Aug; 39(8):1226-30. PubMed ID: 1940531
    [TBL] [Abstract][Full Text] [Related]  

  • 4. AngioSculpt PTCA Balloon Catheter entrapment and detachment managed with stent jailing.
    Pappy R; Gautam A; Abu-Fadel MS
    J Invasive Cardiol; 2010 Oct; 22(10):E208-10. PubMed ID: 20944201
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Potential contribution of open-cell stent design to balloon entrapment and review of techniques to recover.
    Cook JR; Haery C; Montoya A
    J Invasive Cardiol; 2011 Aug; 23(8):E183-7. PubMed ID: 21828403
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Entrapped coronary angioplasty stent balloon due to nondeflation: percutaneous retrieval by a simple technique.
    Girish MP; Gupta MD; Tyagi S
    Catheter Cardiovasc Interv; 2011 Jan; 77(1):58-61. PubMed ID: 20506291
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Successful retrieval of a frayed coronary stent using the peripheral crossover technique.
    Prasad A; Ilapakurti M; Ravandi A
    J Invasive Cardiol; 2011 Apr; 23(4):E69-71. PubMed ID: 21474855
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A rare instructive complication of balloon catheter fracture during percutaneous coronary intervention.
    Nomura T; Higuchi Y; Kato T; Keira N; Tatsumi T
    Cardiovasc Interv Ther; 2016 Jan; 31(1):70-4. PubMed ID: 25708708
    [TBL] [Abstract][Full Text] [Related]  

  • 9. How should I treat a patient to remove a fractured jailed side branch wire?
    Owens CG; Spence MS
    EuroIntervention; 2011 Aug; 7(4):520-7. PubMed ID: 21764672
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Infected coronary artery pseudoaneurysm after repeated percutaneous coronary intervention.
    Lim CP; Ho KL; Tan TT; Wong AS; Tan JW; Chua YL; Su JW
    Ann Thorac Surg; 2011 Feb; 91(2):e17-9. PubMed ID: 21256257
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Frequency, treatment, and consequences of device loss and entrapment in contemporary percutaneous coronary interventions.
    Iturbe JM; Abdel-Karim AR; Papayannis A; Mahmood A; Rangan BV; Banerjee S; Brilakis ES
    J Invasive Cardiol; 2012 May; 24(5):215-21. PubMed ID: 22562915
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous retrieval of entrapped partially inflated broken coronary angioplasty balloon by modified Fogarty technique.
    Girish MP; Gupta MD; Mittal A
    J Invasive Cardiol; 2011 Jul; 23(7):E173-6. PubMed ID: 21725135
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Coronary artery bypass as adequate treatment for entrapped coronary angioplasty catheter.
    Alwaqfi N; Ibrahim K; Kharashgah MN
    Thorac Cardiovasc Surg; 2011 Oct; 59(7):441-2. PubMed ID: 21695675
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Entrapped devices after PCI.
    Alomari I; Snider R; Ponce S; Ahmed B
    Cardiovasc Revasc Med; 2014 Apr; 15(3):182-5. PubMed ID: 24268640
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Retained Coronary Balloon Requiring Emergent Open Surgical Retrieval: An Uncommon Complication Requiring Individualized Management Strategies.
    Desai CK; Petrasko M; Steffen K; Stys T; Stys A
    Methodist Debakey Cardiovasc J; 2019; 15(1):81-85. PubMed ID: 31049154
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intracoronary guidewire emboli: a unique complication and retrieval of the wire.
    Demircan S; Yazici M; Durna K; Yasar E
    Cardiovasc Revasc Med; 2008; 9(4):278-80. PubMed ID: 18928955
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Coronary artery dissection by an oversized balloon.
    Yafi W; Jacquemin L
    BMJ Case Rep; 2014 Dec; 2014():. PubMed ID: 25479753
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Proximal balloon deflation technique: a novel method to retrieve retained or entrapped equipment from the coronary system.
    Ashikaga T; Inagaki H; Satoh Y; Isobe M
    Cardiovasc Revasc Med; 2012; 13(4):253-5. PubMed ID: 22591764
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Successful removal of an entrapped rotablation burr by extracting drive shaft sheath followed by balloon dilatation.
    Sakakura K; Ako J; Momomura S
    Catheter Cardiovasc Interv; 2011 Oct; 78(4):567-70. PubMed ID: 21780279
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Axial deformation during coronary stenting: an extreme case.
    De Caterina AR; Cuculi F; Banning AP
    J Invasive Cardiol; 2012 Jun; 24(6):E122-3. PubMed ID: 22684393
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.