These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 22015124)

  • 21. Surgical retrieval of entrapped coronary angioplasty guidewire from the aorta.
    Ahmad T; Chithiraichelvan S; Patil TA; Jawali V
    Asian Cardiovasc Thorac Ann; 2016 Jan; 24(1):81-4. PubMed ID: 25069851
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Successful fenestration using a chronic total occlusion-dedicated guidewire in a patient with catheter-induced dissection of the right coronary artery.
    Taniguchi N; Takahashi A; Sakamoto S
    J Invasive Cardiol; 2011 Feb; 23(2):84-6. PubMed ID: 21297207
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Retrieval of a detached partially expanded stent using the SpideRX and EnSnare devices--a first report.
    Hussain F; Rusnak B; Tam J
    J Invasive Cardiol; 2008 Feb; 20(2):E44-7. PubMed ID: 18252977
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Troubleshooting and treating the balloon that fails to deflate.
    Gilchrist IC
    Catheter Cardiovasc Interv; 2011 Jan; 77(1):62. PubMed ID: 21181971
    [No Abstract]   [Full Text] [Related]  

  • 25. Retrieving a deformed stent during transradial intervention: an alternative femoral approach using guide catheter shortening.
    Trehan VK; Jain G; Kathuria S; Pandit BN
    Indian Heart J; 2013; 65(3):323-6. PubMed ID: 23809390
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Surgical removal of entrapped and broken percutaneous transluminal coronary angioplasty balloon catheter.
    Singh J; Thingnam SK; Das D; Singh H; Sharma R; Vijayvergia R
    Interact Cardiovasc Thorac Surg; 2007 Feb; 6(1):94-6. PubMed ID: 17669780
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Successful emergent surgical revascularization and retrieval of entrapped drug eluting stent.
    Bruschi G; Colombo P; Piccalò G; Trunfio S; Colombo T; Vitali E
    J Cardiovasc Med (Hagerstown); 2008 Feb; 9(2):182-3. PubMed ID: 18192812
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Removal of a ruptured, detached, and entrapped angioplasty balloon after coronary stenting.
    Madronero JL; Hein F; Bergbauer M
    J Invasive Cardiol; 2000 Feb; 12(2):102-4. PubMed ID: 10731273
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Successful rescue of stuck rotablator burr entrapment using a Kiwami straight catheter.
    Kanazawa T; Kadota K; Mitsudo K
    Catheter Cardiovasc Interv; 2015 Nov; 86(5):942-5. PubMed ID: 25712486
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Consequences and treatment of guidewire entrapment and fracture during percutaneous coronary intervention.
    Danek BA; Karatasakis A; Brilakis ES
    Cardiovasc Revasc Med; 2016 Mar; 17(2):129-33. PubMed ID: 26826011
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Novel use of a local drug delivery catheter for coronary perforation.
    Habara M; Kinoshita Y; Suzuki T
    J Invasive Cardiol; 2011 Jan; 23(1):E236-9. PubMed ID: 21183772
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Surgical removal of guidewire entrapped within stent struts during percutaneous coronary angioplasty.
    Oruc OA; Aksüt M; Bakirci EM; Ekren H; Erkut B
    Heart Surg Forum; 2015 Jun; 18(3):E106-8. PubMed ID: 26115154
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Retrieval of impacted broken balloon by balloon inflation in guiding catheter.
    Mehta V; Pandit BN; Yusuf J; Mukhopadhyay S; Trehan V; Tyagi S
    Cardiovasc Interv Ther; 2014 Jul; 29(3):252-5. PubMed ID: 24178859
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Successful collapse vessel treatment with a syringe for thrombus-aspiration after the guidewire-induced coronary artery perforation.
    Yasuoka Y; Sasaki T
    Cardiovasc Revasc Med; 2010; 11(4):263.e1-3. PubMed ID: 20934662
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Percutaneous retrieval of a fractured guide catheter using contralateral snaring.
    Michael TT; Banerjee S; Brilakis ES
    J Invasive Cardiol; 2012 Aug; 24(8):E176-8. PubMed ID: 22865321
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Stent dislodgement in left anterior descending coronary artery and successful deployment with two parallel wires and a small balloon.
    Ngow H
    Kardiol Pol; 2009 Sep; 67(9):1040-2 discussion 1043. PubMed ID: 19838965
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Fracture, inflation and floatation embolisation of PTCA balloon.
    O'Neill L; Sowbhaga V; Owens P
    BMJ Case Rep; 2015 Jan; 2015():. PubMed ID: 25576524
    [TBL] [Abstract][Full Text] [Related]  

  • 38. An unusual case of guide wire fractured during primary percutaneous coronary intervention, and two year follow-up.
    Kaplan S; Kaplan ST; Kutlu M
    Kardiol Pol; 2010 Nov; 68(11):1291-3. PubMed ID: 21108216
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Percutaneous evacuation of detached hydrophilic coating of jailed guidewire.
    Pawlowski K; Dorniak W; Klaudel J
    J Invasive Cardiol; 2010 Nov; 22(11):E193-5. PubMed ID: 21041863
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An avoidable complication of percutaneous coronary intervention-entrapment of stent and disconnected balloon catheter.
    Lin TH; Chiu CC; Chen HM; Su HM; Voon WC; Lai WT; Sheu SH; Lin YT
    Kaohsiung J Med Sci; 2006 Apr; 22(4):184-8. PubMed ID: 16679300
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.