BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 22020017)

  • 1. Impact of air distribution on efficiency of dust capture from metal grinding--bench test method.
    Jankowski T
    Ind Health; 2011; 49(6):735-45. PubMed ID: 22020017
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficiency of a tool-mounted local exhaust ventilation system for controlling dust exposure during metal grinding operations.
    Ojima J
    Ind Health; 2007 Dec; 45(6):817-9. PubMed ID: 18212477
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effectiveness of dust control methods for crystalline silica and respirable suspended particulate matter exposure during manual concrete surface grinding.
    Akbar-Khanzadeh F; Milz SA; Wagner CD; Bisesi MS; Ames AL; Khuder S; Susi P; Akbar-Khanzadeh M
    J Occup Environ Hyg; 2010 Dec; 7(12):700-11. PubMed ID: 21058155
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Metal dust exposure and control in hand-held grinding operation].
    Ojima J
    Sangyo Eiseigaku Zasshi; 2007 Jan; 49(1):9-11. PubMed ID: 17303933
    [No Abstract]   [Full Text] [Related]  

  • 5. Designing, construction, assessment, and efficiency of local exhaust ventilation in controlling crystalline silica dust and particles, and formaldehyde in a foundry industry plant.
    Morteza MM; Hossein K; Amirhossein M; Naser H; Gholamhossein H; Hossein F
    Arh Hig Rada Toksikol; 2013; 64(1):123-31. PubMed ID: 23585164
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Control of Dust Dispersion From an Enclosed Renovation Site Into Adjacent Areas by Using Local Exhaust Ventilation.
    Kokkonen A; Linnainmaa M; Säämänen A; Kanerva T; Sorvari J; Kolehmainen M; Lappalainen V; Pasanen P
    Ann Work Expo Health; 2019 Apr; 63(4):468-479. PubMed ID: 30877765
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Task-specific noise exposure during manual concrete surface grinding in enclosed areas-influence of operation variables and dust control methods.
    Akbar-Khanzadeh F; Ames AL; Milz SA; Akbar-Khanzadeh M
    J Occup Environ Hyg; 2013; 10(9):478-86. PubMed ID: 23926952
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Dust emission and efficiency of local exhaust ventilation during cast iron grinding.
    Gliński M
    Int J Occup Saf Ergon; 2002; 8(1):95-105. PubMed ID: 11895585
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Laboratory evaluation to reduce respirable crystalline silica dust when cutting concrete roofing tiles using a masonry saw.
    Carlo RV; Sheehy J; Feng HA; Sieber WK
    J Occup Environ Hyg; 2010 Apr; 7(4):245-51. PubMed ID: 20169490
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Reduction of dust during manual grinding of cast iron].
    Gliński M
    Med Pr; 2002; 53(1):89-93. PubMed ID: 12051159
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Crystalline silica dust and respirable particulate matter during indoor concrete grinding - wet grinding and ventilated grinding compared with uncontrolled conventional grinding.
    Akbar-Khanzadeh F; Milz S; Ames A; Susi PP; Bisesi M; Khuder SA; Akbar-Khanzadeh M
    J Occup Environ Hyg; 2007 Oct; 4(10):770-9. PubMed ID: 17763068
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Worker's exposure and dust control in metal grinding operations].
    Ojima J
    Sangyo Eiseigaku Zasshi; 2005 May; 47(3):119-21. PubMed ID: 15977593
    [No Abstract]   [Full Text] [Related]  

  • 13. Evaluation of a Dust Control for a Small Slab-Riding Dowel Drill for Concrete Pavement.
    Echt A; Mead K
    Ann Occup Hyg; 2016 May; 60(4):519-24. PubMed ID: 26826033
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Metals in dust fractions emitted at mechanical workstations.
    Kondej D; Gawęda E
    Int J Occup Saf Ergon; 2012; 18(4):453-60. PubMed ID: 23294651
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Exposure to airborne metals in the manufacture and maintenance of hard metal and stellite blades.
    Linnainmaa M; Kangas J; Kalliokoski P
    Am Ind Hyg Assoc J; 1996 Feb; 57(2):196-201. PubMed ID: 8615327
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An evaluation of on-tool shrouds for controlling respirable crystalline silica in restoration stone work.
    Healy CB; Coggins MA; Van Tongeren M; MacCalman L; McGowan P
    Ann Occup Hyg; 2014 Nov; 58(9):1155-67. PubMed ID: 25261456
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reducing silica and dust exposures in construction during use of powered concrete-cutting hand tools: efficacy of local exhaust ventilation on hammer drills.
    Shepherd S; Woskie SR; Holcroft C; Ellenbecker M
    J Occup Environ Hyg; 2009 Jan; 6(1):42-51. PubMed ID: 19005968
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Reduction of dustiness at non-stationary work stations].
    Gliński M
    Med Pr; 2000; 51(4):401-10. PubMed ID: 11059414
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Local exhaust ventilation for the control of welding fumes in the construction industry--a literature review.
    Flynn MR; Susi P
    Ann Occup Hyg; 2012 Aug; 56(7):764-76. PubMed ID: 22459321
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Application of local exhaust ventilation system and integrated collectors for control of air pollutants in mining company.
    Ghorbani Shahna F; Bahrami A; Farasati F
    Ind Health; 2012; 50(5):450-7. PubMed ID: 22878358
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.