352 related articles for article (PubMed ID: 22025111)
1. Preparation, certification and interlaboratory analysis of workplace air filters spiked with high-fired beryllium oxide.
Oatts TJ; Hicks CE; Adams AR; Brisson MJ; Youmans-McDonald LD; Hoover MD; Ashley K
J Environ Monit; 2012 Feb; 14(2):391-401. PubMed ID: 22025111
[TBL] [Abstract][Full Text] [Related]
2. Interlaboratory evaluation of a standardized inductively coupled plasma mass spectrometry method for the determination of trace beryllium in air filter samples.
Ashley K; Brisson MJ; Howe AM; Bartley DL
J Occup Environ Hyg; 2009 Dec; 6(12):745-50. PubMed ID: 19894175
[TBL] [Abstract][Full Text] [Related]
3. Extraction of beryllium from refractory beryllium oxide with dilute ammonium bifluoride and determination by fluorescence: a multiparameter performance evaluation.
Goldcamp MJ; Goldcamp DM; Ashley K; Fernback JE; Agrawal A; Millson M; Marlow D; Harrison K
J Occup Environ Hyg; 2009 Dec; 6(12):735-44. PubMed ID: 19894174
[TBL] [Abstract][Full Text] [Related]
4. Certification of beryllium mass fraction in SRM 1877 Beryllium Oxide Powder using high-performance inductively coupled plasma optical emission spectrometry with exact matching.
Winchester MR; Turk GC; Butler TA; Oatts TJ; Coleman C; Nadratowski D; Sud R; Hoover MD; Stefaniak AB
Anal Chem; 2009 Mar; 81(6):2208-17. PubMed ID: 19209906
[TBL] [Abstract][Full Text] [Related]
5. Interlaboratory evaluation of trace element determination in workplace air filter samples by inductively coupled plasma mass spectrometry.
Ashley K; Shulman SA; Brisson MJ; Howe AM
J Environ Monit; 2012 Feb; 14(2):360-7. PubMed ID: 22038017
[TBL] [Abstract][Full Text] [Related]
6. Validation of a standardized portable fluorescence method for determining trace beryllium in workplace air and wipe samples.
Agrawal A; Cronin J; Tonazzi J; Mark McCleskey T; Ehler DS; Minogue EM; Whitney G; Brink C; Burrell AK; Warner B; Goldcamp MJ; Schlecht PC; Sonthalia P; Ashley K
J Environ Monit; 2006 Jun; 8(6):619-24. PubMed ID: 16767228
[TBL] [Abstract][Full Text] [Related]
7. Interlaboratory evaluation of an extraction and fluorescence method for the determination of trace beryllium in soils.
Cronin JP; Agrawal A; Adams L; Tonazzi JC; Brisson MJ; White KT; Marlow D; Ashley K
J Environ Monit; 2008 Aug; 10(8):955-60. PubMed ID: 18688465
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of a portable X-ray fluorescence instrument for the determination of lead in workplace air samples.
Morley JC; Clark CS; Deddens JA; Ashley K; Roda S
Appl Occup Environ Hyg; 1999 May; 14(5):306-16. PubMed ID: 10446483
[TBL] [Abstract][Full Text] [Related]
9. Ultra-trace determination of beryllium in occupational hygiene samples by ammonium bifluoride extraction and fluorescence detection using hydroxybenzoquinoline sulfonate.
Ashley K; Agrawal A; Cronin J; Tonazzi J; McCleskey TM; Burrell AK; Ehler DS
Anal Chim Acta; 2007 Feb; 584(2):281-6. PubMed ID: 17386616
[TBL] [Abstract][Full Text] [Related]
10. Interlaboratory evaluation of cellulosic acid-soluble internal air sampling capsules for multi-element analysis.
Andrews RN; Feng HA; Ashley K
J Occup Environ Hyg; 2016; 13(1):40-7. PubMed ID: 26308974
[TBL] [Abstract][Full Text] [Related]
11. Lessons learned in preparing method 29 filters for compliance testing audits.
Martz RF; McCartney JE; Bursey JT; Riley CE
Qual Assur; 2000; 8(3-4):161-7. PubMed ID: 12008884
[TBL] [Abstract][Full Text] [Related]
12. Evaluation of a standardized method for determining soluble silver in workplace air samples.
Drake PL; Dale Marcy A; Ashley K
J Environ Monit; 2006 Jan; 8(1):134-9. PubMed ID: 16395470
[TBL] [Abstract][Full Text] [Related]
13. Performance of laboratories analysing welding fume on filter samples: results from the WASP proficiency testing scheme.
Stacey P; Butler O
Ann Occup Hyg; 2008 Jun; 52(4):287-95. PubMed ID: 18453528
[TBL] [Abstract][Full Text] [Related]
14. Beryllium solubility in occupational airborne particles: Sequential extraction procedure and workplace application.
Rousset D; Durand T
J Occup Environ Hyg; 2016; 13(1):71-83. PubMed ID: 26327570
[TBL] [Abstract][Full Text] [Related]
15. A comparison of X-ray fluorescence and wet chemical analysis of air filter samples from a scrap lead smelting operation.
Harper M; Hallmark TS; Andrew ME; Bird AJ
J Environ Monit; 2004 Oct; 6(10):819-26. PubMed ID: 15480496
[TBL] [Abstract][Full Text] [Related]
16. A comparison of portable XRF and ICP-OES analysis for lead on air filter samples from a lead ore concentrator mill and a lead-acid battery recycler.
Harper M; Pacolay B; Hintz P; Andrew ME
J Environ Monit; 2006 Mar; 8(3):384-92. PubMed ID: 16528423
[TBL] [Abstract][Full Text] [Related]
17. Performance of methods for measurement of exposure to inorganic acids in workplace air.
Breuer D; Howe A
J Environ Monit; 2006 Jan; 8(1):120-6. PubMed ID: 16395468
[TBL] [Abstract][Full Text] [Related]
18. Performance testing of NIOSH Method 5524/ASTM Method D-7049-04, for determination of metalworking fluids.
Glaser R; Kurimo R; Shulman S
J Occup Environ Hyg; 2007 Aug; 4(8):583-95. PubMed ID: 17577749
[TBL] [Abstract][Full Text] [Related]
19. Differences in dissolution behavior in a phagolysosomal simulant fluid for single-constituent and multi-constituent materials associated with beryllium sensitization and chronic beryllium disease.
Stefaniak AB; Day GA; Hoover MD; Breysse PN; Scripsick RC
Toxicol In Vitro; 2006 Feb; 20(1):82-95. PubMed ID: 16061346
[TBL] [Abstract][Full Text] [Related]
20. Trace-level beryllium analysis in the laboratory and in the field: state of the art, challenges and opportunities.
Brisson MJ; Ashley K; Stefaniak AB; Ekechukwu AA; Creek KL
J Environ Monit; 2006 Jun; 8(6):605-11. PubMed ID: 16767226
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]