689 related articles for article (PubMed ID: 22029045)
1. Porous Cu-NiO modified glass carbon electrode enhanced nonenzymatic glucose electrochemical sensors.
Zhang X; Gu A; Wang G; Huang Y; Ji H; Fang B
Analyst; 2011 Dec; 136(24):5175-80. PubMed ID: 22029045
[TBL] [Abstract][Full Text] [Related]
2. Nickel oxide microfibers immobilized onto electrode by electrospinning and calcination for nonenzymatic glucose sensor and effect of calcination temperature on the performance.
Cao F; Guo S; Ma H; Shan D; Yang S; Gong J
Biosens Bioelectron; 2011 Jan; 26(5):2756-60. PubMed ID: 21074398
[TBL] [Abstract][Full Text] [Related]
3. Nonenzymatic glucose sensor based on nickel(II)oxide/ordered mesoporous carbon modified glassy carbon electrode.
Luo L; Li F; Zhu L; Ding Y; Zhang Z; Deng D; Lu B
Colloids Surf B Biointerfaces; 2013 Feb; 102():307-11. PubMed ID: 23006570
[TBL] [Abstract][Full Text] [Related]
4. Non-enzymatic glucose sensor based on a g-C
Lotfi Z; Gholivand MB; Shamsipur M
Anal Biochem; 2021 Mar; 616():114062. PubMed ID: 33285122
[TBL] [Abstract][Full Text] [Related]
5. Fixure-reduce method for the synthesis of Cu2O/MWCNTs nanocomposites and its application as enzyme-free glucose sensor.
Zhang X; Wang G; Zhang W; Wei Y; Fang B
Biosens Bioelectron; 2009 Jul; 24(11):3395-8. PubMed ID: 19473828
[TBL] [Abstract][Full Text] [Related]
6. A sensitive nonenzymatic glucose sensor in alkaline media with a copper nanocluster/multiwall carbon nanotube-modified glassy carbon electrode.
Kang X; Mai Z; Zou X; Cai P; Mo J
Anal Biochem; 2007 Apr; 363(1):143-50. PubMed ID: 17288983
[TBL] [Abstract][Full Text] [Related]
7. Highly sensitive nonenzymatic glucose sensor based on electrospun copper oxide-doped nickel oxide composite microfibers.
Cao F; Guo S; Ma H; Yang G; Yang S; Gong J
Talanta; 2011 Oct; 86():214-20. PubMed ID: 22063533
[TBL] [Abstract][Full Text] [Related]
8. Sensitive and selective non-enzymatic detection of glucose by monodispersed NiO @ S-doped hollow carbon sphere hybrid nanostructures.
Madhuvilakku R; Mariappan R; Alagar S; Piraman S
Anal Chim Acta; 2018 Dec; 1042():93-108. PubMed ID: 30428993
[TBL] [Abstract][Full Text] [Related]
9. In situ growth of copper sulfide nanoparticles on ordered mesoporous carbon and their application as nonenzymatic amperometric sensor of hydrogen peroxide.
Bo X; Bai J; Wang L; Guo L
Talanta; 2010 Apr; 81(1-2):339-45. PubMed ID: 20188929
[TBL] [Abstract][Full Text] [Related]
10. Nonenzymatic electrochemical detection of glucose using well-distributed nickel nanoparticles on straight multi-walled carbon nanotubes.
Nie H; Yao Z; Zhou X; Yang Z; Huang S
Biosens Bioelectron; 2011 Dec; 30(1):28-34. PubMed ID: 21955756
[TBL] [Abstract][Full Text] [Related]
11. Nonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrode.
Liu Y; Teng H; Hou H; You T
Biosens Bioelectron; 2009 Jul; 24(11):3329-34. PubMed ID: 19450966
[TBL] [Abstract][Full Text] [Related]
12. Highly sensitive and selective nonenzymatic detection of glucose using three-dimensional porous nickel nanostructures.
Niu X; Lan M; Zhao H; Chen C
Anal Chem; 2013 Apr; 85(7):3561-9. PubMed ID: 23458297
[TBL] [Abstract][Full Text] [Related]
13. A highly sensitive non-enzymatic glucose sensor based on bimetallic Cu-Ag superstructures.
Li H; Guo CY; Xu CL
Biosens Bioelectron; 2015 Jan; 63():339-346. PubMed ID: 25113052
[TBL] [Abstract][Full Text] [Related]
14. Novel Ag@TiO2 nanocomposite synthesized by electrochemically active biofilm for nonenzymatic hydrogen peroxide sensor.
Khan MM; Ansari SA; Lee J; Cho MH
Mater Sci Eng C Mater Biol Appl; 2013 Dec; 33(8):4692-9. PubMed ID: 24094177
[TBL] [Abstract][Full Text] [Related]
15. Fabrication and characterization of non-enzymatic glucose sensor based on ternary NiO/CuO/polyaniline nanocomposite.
Ghanbari Kh; Babaei Z
Anal Biochem; 2016 Apr; 498():37-46. PubMed ID: 26778527
[TBL] [Abstract][Full Text] [Related]
16. Highly sensitive nonenzymatic glucose and H2O2 sensor based on Ni(OH)2/electroreduced graphene oxide--multiwalled carbon nanotube film modified glass carbon electrode.
Gao W; Tjiu WW; Wei J; Liu T
Talanta; 2014 Mar; 120():484-90. PubMed ID: 24468400
[TBL] [Abstract][Full Text] [Related]
17. Nonenzymatic amperometric determination of glucose by CuO nanocubes-graphene nanocomposite modified electrode.
Luo L; Zhu L; Wang Z
Bioelectrochemistry; 2012 Dec; 88():156-63. PubMed ID: 22522031
[TBL] [Abstract][Full Text] [Related]
18. Silver oxide nanowalls grown on Cu substrate as an enzymeless glucose sensor.
Fang B; Gu A; Wang G; Wang W; Feng Y; Zhang C; Zhang X
ACS Appl Mater Interfaces; 2009 Dec; 1(12):2829-34. PubMed ID: 20356163
[TBL] [Abstract][Full Text] [Related]
19. A novel NiO-Au hybrid nanobelts based sensor for sensitive and selective glucose detection.
Ding Y; Liu Y; Parisi J; Zhang L; Lei Y
Biosens Bioelectron; 2011 Oct; 28(1):393-8. PubMed ID: 21852103
[TBL] [Abstract][Full Text] [Related]
20. Amperometric microsensor for direct probing of ascorbic acid in human gastric juice.
Hutton EA; Pauliukaitė R; Hocevar SB; Ogorevc B; Smyth MR
Anal Chim Acta; 2010 Sep; 678(2):176-82. PubMed ID: 20888449
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]