These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

198 related articles for article (PubMed ID: 22035698)

  • 1. Hydrodynamic chromatography of macromolecules using polymer monolithic columns.
    Edam R; Eeltink S; Vanhoutte DJ; Kok WT; Schoenmakers PJ
    J Chromatogr A; 2011 Dec; 1218(48):8638-45. PubMed ID: 22035698
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fast and efficient size-based separations of polymers using ultra-high-pressure liquid chromatography.
    Uliyanchenko E; Schoenmakers PJ; van der Wal S
    J Chromatogr A; 2011 Mar; 1218(11):1509-18. PubMed ID: 21300362
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Deformation and degradation of polymers in ultra-high-pressure liquid chromatography.
    Uliyanchenko E; van der Wal S; Schoenmakers PJ
    J Chromatogr A; 2011 Sep; 1218(39):6930-42. PubMed ID: 21875706
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On the chromatographic efficiency of analytical scale column format porous polymer monoliths: interplay of morphology and nanoscale gel porosity.
    Nischang I
    J Chromatogr A; 2012 May; 1236():152-63. PubMed ID: 22443891
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A study of the effects of column porosity on gradient separations of proteins.
    Urban J; Jandera P; Kucerová Z; van Straten MA; Claessens HA
    J Chromatogr A; 2007 Oct; 1167(1):63-75. PubMed ID: 17804002
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Silica particles encapsulated poly(styrene-divinylbenzene) monolithic stationary phases for micro-high performance liquid chromatography.
    Bakry R; Stöggl WM; Hochleitner EO; Stecher G; Huck CW; Bonn GK
    J Chromatogr A; 2006 Nov; 1132(1-2):183-9. PubMed ID: 16920130
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monolithic poly(1,2-bis(p-vinylphenyl)ethane) capillary columns for simultaneous separation of low- and high-molecular-weight compounds.
    Greiderer A; Ligon SC; Huck CW; Bonn GK
    J Sep Sci; 2009 Aug; 32(15-16):2510-20. PubMed ID: 19598164
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization of branched ultrahigh molar mass polymers by asymmetrical flow field-flow fractionation and size exclusion chromatography.
    Otte T; Pasch H; Macko T; Brüll R; Stadler FJ; Kaschta J; Becker F; Buback M
    J Chromatogr A; 2011 Jul; 1218(27):4257-67. PubMed ID: 21238968
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Novel method to prepare polystyrene-based monolithic columns for chromatographic and electrophoretic separations by microwave irradiation.
    Zhang YP; Ye XW; Tian MK; Qu LB; Choi SH; Gopalan AI; Lee KP
    J Chromatogr A; 2008 Apr; 1188(1):43-9. PubMed ID: 18037422
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flow-through pore characteristics of monolithic silicas and their impact on column performance in high-performance liquid chromatography.
    Skudas R; Grimes BA; Thommes M; Unger KK
    J Chromatogr A; 2009 Mar; 1216(13):2625-36. PubMed ID: 19233368
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of monomer mixture composition on structure and chromatographic properties of poly(divinylbenzene-co-ethylvinylbenzene-co-2-hydroxyethyl methacrylate) monolithic rod columns for separation of small molecules.
    Smirnov KN; Dyatchkov IA; Telnov MV; Pirogov AV; Shpigun OA
    J Chromatogr A; 2011 Jul; 1218(30):5010-9. PubMed ID: 21194698
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Nanostructured porous polymer monolithic columns for capillary liquid chromatography of peptides.
    Vaast A; Terryn H; Svec F; Eeltink S
    J Chromatogr A; 2014 Dec; 1374():171-179. PubMed ID: 25498556
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of different polymerisation parameters on the separation efficiency of monolithic poly(phenyl acrylate-co-1,4-phenylene diacrylate) capillary columns.
    Bisjak CP; Trojer L; Lubbad SH; Wieder W; Bonn GK
    J Chromatogr A; 2007 Jun; 1154(1-2):269-76. PubMed ID: 17449047
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preparation of glycerol dimethacrylate-based polymer monolith with unusual porous properties achieved via viscoelastic phase separation induced by monodisperse ultra high molecular weight poly(styrene) as a porogen.
    Aoki H; Kubo T; Ikegami T; Tanaka N; Hosoya K; Tokuda D; Ishizuka N
    J Chromatogr A; 2006 Jun; 1119(1-2):66-79. PubMed ID: 16513125
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preparation and characterization of lauryl methacrylate-based monolithic microbore column for reversed-phase liquid chromatography.
    Shu S; Kobayashi H; Kojima N; Sabarudin A; Umemura T
    J Chromatogr A; 2011 Aug; 1218(31):5228-34. PubMed ID: 21703629
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Branched polymers characterized by comprehensive two-dimensional separations with fully orthogonal mechanisms: molecular-topology fractionation×size-exclusion chromatography.
    Edam R; Mes EP; Meunier DM; Van Damme FA; Schoenmakers PJ
    J Chromatogr A; 2014 Oct; 1366():54-64. PubMed ID: 25282310
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simple capillary flow porometer for characterization of capillary columns containing packed and monolithic beds.
    Fang Y; Tolley HD; Lee ML
    J Chromatogr A; 2010 Oct; 1217(41):6405-12. PubMed ID: 20810116
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Structure and performance of silica-based monolithic HPLC columns.
    Altmaier S; Cabrera K
    J Sep Sci; 2008 Aug; 31(14):2551-9. PubMed ID: 18618471
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Parameters affecting the separation of intact proteins in gradient-elution reversed-phase chromatography using poly(styrene-co-divinylbenzene) monolithic capillary columns.
    Detobel F; Broeckhoven K; Wellens J; Wouters B; Swart R; Ursem M; Desmet G; Eeltink S
    J Chromatogr A; 2010 Apr; 1217(18):3085-90. PubMed ID: 20347095
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of monolithic silica capillary columns with increased phase ratios and small-sized domains.
    Hara T; Kobayashi H; Ikegami T; Nakanishi K; Tanaka N
    Anal Chem; 2006 Nov; 78(22):7632-42. PubMed ID: 17105153
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.