  • 1. Sensing and responding to compliance changes during manual ventilation using a lung model: can we teach healthcare providers to improve?
    Bowman TA; Paget-Brown A; Carroll J; Gurka MJ; Kattwinkel J
    J Pediatr; 2012 Mar; 160(3):372-376.e1. PubMed ID: 22048042
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Responding to compliance changes in a lung model during manual ventilation: perhaps volume, rather than pressure, should be displayed.
    Kattwinkel J; Stewart C; Walsh B; Gurka M; Paget-Brown A
    Pediatrics; 2009 Mar; 123(3):e465-70. PubMed ID: 19188267
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A strategy to optimise the performance of the mouth-to-bag resuscitator using small tidal volumes: effects on lung and gastric ventilation in a bench model of an unprotected airway.
    Zecha-Stallinger A; Wenzel V; Wagner-Berger HG; von Goedecke A; Lindner KH; Hörmann C
    Resuscitation; 2004 Apr; 61(1):69-74. PubMed ID: 15081184
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of three neonatal resuscitation devices.
    Bennett S; Finer NN; Rich W; Vaucher Y
    Resuscitation; 2005 Oct; 67(1):113-8. PubMed ID: 16081202
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The self-inflating resuscitation bag delivers high oxygen concentrations when used without a reservoir: implications for neonatal resuscitation.
    Johnston KL; Aziz K
    Respir Care; 2009 Dec; 54(12):1665-70. PubMed ID: 19961632
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Neonatal resuscitation 1: a model to measure inspired and expired tidal volumes and assess leakage at the face mask.
    O'Donnell CP; Kamlin CO; Davis PG; Morley CJ
    Arch Dis Child Fetal Neonatal Ed; 2005 Sep; 90(5):F388-91. PubMed ID: 15871990
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Oxygen delivery using neonatal self-inflating bags without reservoirs.
    Sugiura T; Urushibata R; Komatsu K; Shioda T; Ota T; Sato M; Okubo Y; Fukuoka T; Hosono S; Tamura M
    Pediatr Int; 2017 Feb; 59(2):154-158. PubMed ID: 27706892
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Neonatal and pediatric manual hyperinflation: influence of oxygen flow on ventilation parameters.
    de Oliveira PM; Almeida-Junior AA; Almeida CC; de Oliveira Ribeiro MÂ; Ribeiro JD
    Respir Care; 2013 Dec; 58(12):2127-33. PubMed ID: 24026188
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Manual ventilation devices in neonatal resuscitation: tidal volume and positive pressure-provision.
    Roehr CC; Kelm M; Fischer HS; Bührer C; Schmalisch G; Proquitté H
    Resuscitation; 2010 Feb; 81(2):202-5. PubMed ID: 19926383
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of Simulated Ventilation Techniques With the Upright and Conventional Self-Inflating Neonatal Resuscitators.
    Narayanan I; Mendhi M; Bansil P; Coffey PS
    Respir Care; 2017 Nov; 62(11):1428-1436. PubMed ID: 28830928
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance and Acceptability of Two Self-Inflating Bag-Mask Neonatal Resuscitator Designs.
    Coffey PS; Saxon EA; Narayanan I; DiBlasi RM
    Respir Care; 2015 Sep; 60(9):1227-37. PubMed ID: 26152468
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator's Training.
    do Prado C; Guinsburg R; de Almeida MF; Mascaretti RS; Vale LA; Haddad LB; Rebello CM
    PLoS One; 2016; 11(2):e0148475. PubMed ID: 26859896
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of self-inflating bags for neonatal resuscitation.
    Oddie S; Wyllie J; Scally A
    Resuscitation; 2005 Oct; 67(1):109-12. PubMed ID: 16150527
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The effect of a PEEP valve on a Laerdal neonatal self-inflating resuscitation bag.
    Morley CJ; Dawson JA; Stewart MJ; Hussain F; Davis PG
    J Paediatr Child Health; 2010 Jan; 46(1-2):51-6. PubMed ID: 19943861
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Oxygen delivery using neonatal self-inflating resuscitation bags without a reservoir.
    Thió M; Bhatia R; Dawson JA; Davis PG
    Arch Dis Child Fetal Neonatal Ed; 2010 Sep; 95(5):F315-9. PubMed ID: 19843501
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Equipment and operator training denote manual ventilation performance in neonatal resuscitation.
    Roehr CC; Kelm M; Proquitté H; Schmalisch G
    Am J Perinatol; 2010 Oct; 27(9):753-8. PubMed ID: 20458664
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Providing PEEP during neonatal resuscitation: which device is best?
    Dawson JA; Gerber A; Kamlin CO; Davis PG; Morley CJ
    J Paediatr Child Health; 2011 Oct; 47(10):698-703. PubMed ID: 21449898
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Emergency airway management-- comparison of various strategies in an unsecured airway].
    Dörges V; Ocker H; Neubert E; Schumann T; Wenzel V
    Wien Klin Wochenschr; 2001 Mar; 113(5-6):186-93. PubMed ID: 11293948
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Newborn manikin study shows that physicians often fail to detect correct lung compliance when using a self-inflating bag.
    Boldingh AM; Solevåg AL; Benth JŠ; Klingenberg C; Nakstad B
    Acta Paediatr; 2016 Feb; 105(2):172-7. PubMed ID: 26153507
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Breathing circuit compliance and accuracy of displayed tidal volume during pressure-controlled ventilation of infants: A quality improvement project.
    Glenski TA; Diehl C; Clopton RG; Friesen RH
    Paediatr Anaesth; 2017 Sep; 27(9):935-941. PubMed ID: 28504341
    [TBL] [Abstract][Full Text] [Related]  